Council archive · source document
Approved Plans - OPW14/0043
Plans and drawings: the text below has words only, no drawings.
GIBSON ROAD NATURE STRIP
3.0m
BOUNDAR 1800mm HIGH SOLID
Y LINE HWD TIMBER FENCE
3.0 18.947m
PP LAP POOL
SITE INFORMATION
4038
SPACE FOR TWO EAVES LINE
WHEELIE BINS LOT 67 ON RP842163
3.0 18 SUNSEEKER CLOSE, NOOSAVILLE
FENCE DECK PARISH: WEYBA
AREA COUNTY: MARCH
UNIT 3-2 BEDROOM LOCAL GOVERNMENT: SUNSHINE COAST RC
6709 SC 90 sqm
GFA 107.2 sqm SITE AREA: 931 sqm
GFL 2.60 2396
SITE COVERAGE: 36.90%
DRIVEWAY GROSS FLOOR AREA: 372.4 sqm
260sqm LANDSCAPING AREA: 340 sqm
PP
LANDSCAPING AREA
2.5
LOT 66
DE
CK
2.5 OL
46.199m
PO
36.379m
P -
LA
NOOSA COUNCIL
APPROVED PLANS
BOUNDARY LINE
APPROX. LOCATION
UNIT 2-3 BEDROOM
BOUNDARY LINE
OFNEIGHBOURING
APPROX. LOCATION OF SC 127 sqm BUILDING OPW14/0043 7 FEB 2014
NEIGHBOURING GFA 133.0 sqm
DE
BUILDING GFL 2.60
CK
LOT 72
PATHWAY
DECK
AREA
4015
1400
4034 UNIT 1-3 BEDROOM
SC 127 sqm
GFA 132.2 sqm
GFL 2.60 LEGEND
PP
GFA GROSS FLOOR AREA
DECK GFL GROUND FLOOR LEVEL
Security Gate at this location is NOT AREA
approved and contrary to the O OL SC SITE COVER
CONTOUR LINES
P 2.5
conditions of MCU13/0080 approval P 2.0 PP POOL PUMPS
LA
LOT 67 LIN
E SITE PLAN
Pram Ramp is required - Y
VISITOR BAY DAR RENDER BLOCKWORK
1 : 200
location to be agreed on FENCE
UN
at the pre-start meeting SPACE FOR SIX 5.4 x 2.5 BO 2M WIDE NEW CONCRETE PATHWAY TO
WHEELIE BINS CURRENT AUSTRALIAN STANDARDS.
ELECTRIC
GATE SUNSEEKER Signed by Owner DATED 19/10/2013 Signed by Contractor DATED 19/10/2013
DRIVEWAY CROSSOVER IN
ACCORDANCE WITH IPWEAQ
STANDARD DRAWING SEQ R-050.
LETTERBOXES
RENDERED
CONCRETE BLOCK
CLOSE NOOSAVILLE TOWNHOUSES Scale As indicated
2.0 LIBERTE ADVENTURES
Date 26/02/2013
DRIVEWAY WIDTH TO BE 6M AT THE FRONT FENCE Steven Campbell Project No. 13-054
KERB LINE AND MINIMUM WIDTH OF 3M
WITHIN THE PROPERTY.
CROSSOVER
6000 * KERB
J
I
No.
ISSUED FOR OPERATIONAL WORKS
POOLS ADDED
Revision
05/02/2014
25/01/2014
Date
steve@campbellbuilding
designs.com.au
Ph. 07 5471 0571
Mob: 0428762230
18 Sunseeker Close, Noosaville
SITE PLAN Lic No. 1170438
Approved By
Drawn by
A101 J
SC
Revision
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 2 pages
Page 2
--
NOOSA COUNCIL
APPROVED PLANS
OPW14/0043 7 FEB 2014
[OCR of page images]
RP842163
4, ~ 54x25 “9
JOIN TO LAWFUL
POINT OF
DISCHARGE AT:
ILO.700
CROSSOVER
SCREW IN
RL: 1.825
_ - x ;
DNARE —
a VONCRE TE.
BOUNDARY LINE ay J a _ _
A
J v “
-~ 30 —-—— NO RETENTION
S 4 S
. 1 , g a WITH RETENTION
% LANDSCAPING AREA a oO 20. ~
% Be TOTAL 318sqm 4
se, 3
a 7 a
—_ = 10 -——<—<—
NZ é =
%: ™~
L 0 T ! T T T T
az > 0 2 4 6 8 10 12 14 16 18 20
p 2, |) TIME (MINS.)
. -
te ae Ml STORMWATER HYDROGRAPH THROUGH TANK
: . | wey PEAK FLOW MITIGATION THROUGH ON SITE RETENTION TANK
4 Doe 5
Tos an de. : . UG CALCULATION DATA OF PEAK FLOW MITIGATION:
a J | aA CARPORT L’DRY BED 2 SITE CATCHMENT AREA: 931sqm
5 4 tae JOG c POST DEVELOPMENT IMPERVIOUS AREA: 702sqm
- Sos fe a, / |i . Q100:
4 a So. ( SH \ PRE DEVELOPMENT FLOW: 74L/sec
- ; aap ai I |L_LBATH \ POST DEVELOPMENT FLOW (NO RETENTION): 82L/sec
49 a . - — 7 REDUCTION REQUIRED: 8BL/sec
4 |DRIAY EW Ay > - L ROOF CATCHMENT AREA ENTERING TANK: 401sqm
| . a -s a. y GARAGE — GFL 2600 | - MAX Q20 DESIGN FLOW ENTERING TANK: 28L/sec
Sos LS te, S _ 0 IWR REDUCTION PROVIDED WITH 6,000L TANK: 16L/sec
FFL2.500/b: =” aFFL2.450°% |” FFL2500-¢¢ FFL2.500-$- E| | TANK VOLUME PROVIDED 6,000L > 5,700L
DRIVEWAY * ae \ | 1
“ 260sqm ~ Lf
. a a > .
_ 3 *G . — \
| ———+
4A 4 SBhe . ao
L a) - “ a> fo ° ~~
oF le : :
eV “ay? — 1 LANDSCAPING © 100 ventilation #600 access cover
a o> <3} 4 location to suit gas tight lid FFL2.200
: L Ly JL.
= 4 5 =
200
B “YL 6000Ltr
7 XN bE for retention 800
, KY 2D: : |] \#80 sLow LEAK
a ; lL) J | |
a. nR 2 -IL1.000
& | Oo
\J (El \ ‘| 2 8000Ltr 225
J ~ He \ Oo, r 7 ‘ 3
BUP13656 4 A y Bhs | harvesting
J AY) | [| RLO.350 Overflow
\/ - |OD-.- a ' CO] ¢ Ct | [
\ NS f: 4 =] | L
4 a ‘ =) la] fi |
° eo ge vo | i ! 3500 ‘
o]|o |
- |
\Y Nt pea } 7 | | TANK _ASSEMBLEY
JL o ~ . z COMBINED HARVESTING/RETENTION TANK
. yD FOR DETAILS REFER TO SUPPLIER: ALLCASTPRECAST
: . & SP166568 TOTAL TANK CAPACITY: 14,000 LITRE
\7 4 ty 7 8 HEAVY DUTY TRAFFICABLE, TYPE PRECAST
., 5
CTyr aT ~ . eo oO LOT 72
O STOREY J SO ge Jee 3
RENDERED UNITS FFL2.420-P “ FFL2.300- .
\4 a _
og -
/ 4 A I 4 4 So.
4 .
LOT 67
\Y a9 a. ye
c 4 a .
z - 4
\ fa Haz DISCLAIMER — ENSURE ORIGINAL SIZE DRAWING IS USED
7S FOR ASSESSMENT, TENDERING AND CONSTRUCTION.
v 2
/ , [Amd Description Date
A “ ‘
\Z “Ca a
M/ a ta |
N a, - STORMWATER ASSESSMENT:
FFL2.360-- -
QUALITY:
AS PER SP4—2010 STATE GOVERNMENT (HEALTHY WATERWAYS) POLICY THIS
DEVELOPMENT IS UNDER 6 UNITS AND LESS THAN 2,500sqm SIZE — THEREFORE NO
TREATMENT IS_ REQUIRED A | GARAGE 3 & DRIVEWAY LEVELS REVISED 22-08-13
QUANTITY: Issue Notes Date
TO PREVENT LOCALISED WORSENING EFFECTS UPON DOWNSTREAM PROPERTIES A
MEASURE FOR PEAK FLOW MITIGATION IS REQUIRED. a RETENTION TANK VOLUME SHALL For Development Approval X
BE PROVIDED AS PER DETAILED TANK ASSEMBLEY. For Building Approval 25-06-15
For Tender
HARVESTING/RETENTION TANK 20 0 L Q A TANK HARVESTING VOLUME SHALL BE PROVIDED TO PROVIDE FOR THE OPERATIONS For Construction
3 : . LANDS@® OF WC’s, WM’s AND HC’s.
TYPE PRE FABRICATED, IN on ee Nel SU, As Constructed
GROUND AS PER DETAILED Soe 4
ae ASSEMBLEY. . - ; © ae a
———______ TOTAL capacity 14,000 [> oe: = I ik1.000 - BS wy ao . RENDER BLOCKWORK
ETRES | 9225'S 4 . Z FENCE i
| ~ 1L0.950—— wt . / , Hvd li wet
FFL2A50% | — ¢— BRO PN TTT yaraulic =:
wv. vO ~~ 4 t v oe 4 4 | t Wa 7
E . . : . [e225 visitor BAY $225 7 - |
- ae IL0.900 | / ? . .
: 4 a al o/ Z contact: Reinhold Koenning MiEAust RPEQ No 7023
: y PO Box 181
Moffat Beach, QLD, 4551 AHSCA
email: [email protected]
PH: (07) 5491 4333
FX: (07) 5491 4233
~ CLIENT :
NOOSA COUNCIL LIBERTE ADVENTURES
APPROVED PLANS LO STEVEN. CAMPBELL |
(PROJECT: 18 SUNSEEKER CLOSE »
OPW14/0043 7 FEB 2014 cane
DRAWING TITLE:
OPERATIONAL WORKS
STORMWATER
DRAINAGE
Design] HH. checked] h [Date | 25-06-13 | Dwg. No. ‘AMD.
\ Scale: 1: 100 oN At UN.o.| 2 Of 4 2774—-OP2 yy,
RPD:— LOT 67 RP 842163
Page 3
LEGEND PRIVATE LANDSCAPED AREAS
GIBSON ROAD NATURE STRIP PROPOSED BUILDINGS UNIT 1 75 sqm
UNIT 2 95 sqm
BOUNDARY LINE UNIT 3 120 sqm
FENCE LAWN AREA
-
PAVING
FENCE
NOOSA COUNCIL
FENCE
LAWN AREA CONCRETE APPROVED PLANS
GATE
OPW14/0043 7 FEB 2014
FENCE 1800mm HIGH SOLID TIMBER FENCE
PAVING
DOUBLE GATE
UNIT 3 PLANT SCHEDULE PLANTING
LOT 66 SYMBOL DENSITY SIZE
BOTANICAL NAME COMMON NAME
Grasses
PATHWAY FENCE Lomandra longifolia Mat Rush
1 plant/2m 140 pot
FENCE 2
Pennisetum advena Purple Fountain grass
1 plant/2m 140 pot
Poa labillardieri Common tussock-grass 2
LAWN LAWN
AREA MIXED SPECIES BUSHS -under 1m high:
1 plant/2m 140 pot
2
PA
Austromyrtus dulcis Midyim Berry
Austromyrtus tenuifolia Narrow Leaf Myrtle
VI
NG
Dianella caerulea Paroo Lily
1 plant/3m 200 pot
AY Doryanthes excelsa Gymea Lily
2
H W
T FENCE MIXED SPECIES BUSHS - up to 2.5m:
PA Callistemon ‘Hinchinbrook’ Hinchinbrook Bottlebrush
UNIT 2 Acacia fimbriata (dwarf)- Dwarf Fringed wattle
GATE Melastoma affine Blue Tongue
BOUNDARY LINE
1 plant/5m 200 pot
NEIGHBOURIN Alpine caerulea Native ginger
BOUNDARY LINE
Eugenia reinwardtiana Cedar Bay Cherry 2
G BUILDING
LAWN Leptospermum ‘Cardwell’ Leptospermum ‘Cardwell’
PA Austromyrtus inophloia ‘Blushing Beauty
Grevillea ‘Robyn Gordon’ or ‘Superb’
VI
NG
Banksia spinulosa (dwarf form) Hairpin Banksia
DRIVEWAY LOT 72 MIXED SPECIES TREES - 2.5m-5m:
Hakea salicifolia Willow-leaved Hakea
Backhousia myrtifolia Cinnamon Myrtle 1 plant/10
PATHWAY
m2
Rhodamia sessiflora Rhodamia sessiflora
planted
UNIT 1 Hovea acutifolia Northern Hovea
randomly tube stock
Grevillea ‘Honey Gem’ or ‘Moonlight’
Banksia aemula Wallum Banksia on north
and east
Banksia spinulosa Hairpin Banksia
boundary
Banksia ericifolia Heath Banksia
AY
W
TH
PA
EXISTING FENCE LOT 67 FENCE
GATE EA
COMMUNAL AR
N EXISTING
GARDEN
LA
W
PATWAY LANDSCAPE PLAN
WHEELIE BINS
COMMUNAL GARDEN 1 : 200
RENDERED VISITOR
CONCRETE BLOCK PARKING 2M WIDE NEW CONCRETE PATHWAY TO
FRONT FENCE CURRENT AUSTRALIAN STANDARDS.
SE
ELECTRIC
Signed by Owner DATED 19/10/2013 Signed by Contractor DATED 19/10/2013
GATE
C L O
KERB
EK ER NOOSAVILLE TOWNHOUSES Scale As indicated
SE
UN
Date 26/02/2013
EXISTING RENDERED LIBERTE ADVENTURES
Steven Campbell
PATWAY Security Gate at this location is NOT
approved and contrary to the
CONCRETE BLOCK
FRONT FENCE
S J ISSUED FOR OPERATIONAL WORKS 05/02/2014 steve@campbellbuilding
designs.com.au
18 Sunseeker Close, Noosaville
Project No.
Drawn by
13-054
SC
I OPERATIONAL WORKS 03/02/2014 LANDSCAPE PLAN Lic No. 1170438
conditions of MCU13/0080 approval
No. Revision Date
Ph. 07 5471 0571
Mob: 0428762230 Approved By
A220 J
Revision
Used in these records
APPROVED PLANS - OPW14/0043Related documentApplication case desk ↗
About this file
- File size
- 571 KB (small file)
- File type
No other editions are linked here.