PARAPET

IN. BOXGUTTER =

DP. 300x175mm

S_PARAPET
PARAPET

ENSUITE -> =

3085x2170mm  B 3
o

TILE 5 $

770

6 L\

BED 1

4255x3225mm
VINYL PLANK

21

BED 2

4255x3170mm
VINYL PLANK

0321 FGW

7
f
820.

2H2LWW
8

—

DECK

3525x2440mm.
TIMBER

HANDRAIL

HANDRAIL

(03 \ PROPOSED PLAN - LEVEL 2
YT SCALE 1:100

 

LEGEND

AW
COL
cT
DHW
DP
DRY
FW
DW
FGW
HB
Lvw

   
  
  

04518 FGW.

NOTE

AWNING WINDOW OF OVERFLOW UNLESS NOTED OTHERWISE, ALL EXISTING
STEEL COLUMN OV OVEN BUILT WORKS ARE TO REMAIN. FOR FURTHER
COOKTOP P PANTRY CLARIFICATION ON EXTENT OF DEMOLITION
DOUBLE HUNG WINDOW REF REFRIGERATOR WORKS, REFER TO PROPOSED FLOOR PLAN FOR
DOWNPIPE SGD SLIDING GLASS DOOR PROPOSED RECONFIGURATION LAYOUT, WALL
CLOTHES DRYER SGW SLIDING GLASS WINDOW SETOUT DIMENSIONS AND OPENING LOCATIONS.
FLOOR WASTE SHR SHOWER

DISHWASHER SWP SANITARY WASTE PIPE

FIXED GLASS WINDOW Wwe TOILET

HAND BASIN WM ~~ WASHING MACHINE

LOUVRE WINDOW

ENSUITE

3140x2170mm

TILE

SCREENING

ENSUITE

2450x2200mm
TILE

2115 FGW

ROOF BELOW

    

STORAGE

T2LVWy 21

DECK BELOW

3530x1000mm
CARPET.

FAMILY ROOM

BREAKOUT 6515x2955mm
3440x3080mm. CARPET
CARPET

   
  
  
 
        
     
   
  
   
 

 

T1236 LWW

SCREENING

   
    
 
 

    

     
   

Ti U

E
Al

04518 FGW.
SCREENING

((04\ PROPOSED PLAN - LEVEL 3

 

Yo) SCALE 1:100

NOTES

1. ALL CONSTRUCTION WORK UNDERTAKEN
IS TO COMPLY WITH THE NATIONAL
CONSTRUCTION CODE (BCA), RELEVANT
AUSTRALIAN STANDARDS AND
APPLICABLE LOCAL AUTHORITY
REQUIREMENTS.

2. ALL SETBACK/SETOUT DIMENSIONS ARE
TO BE CHECKED AND VERIFIED ON SITE
PRIOR TO CONSTRUCTION,

AS

ROOF BELOW

     
         
  

  
  

   

PARAPET
ROOF GARDEN

PARAPET

 
   
 

THESE DRAWINGS ARE DESIGN CONCEPTS
ONLY AND SHALL NOT BE USED IN ANY
WAY FOR STRUCTURAL PURPOSES. REFER

TO STRUCTURAL ENGINEER'S DETAILS
FOR ALL MEMBER SIZES, SPECIFICATIONS
AND SITE SPECIFIC STRUCTURAL
REQUIREMENTS.

 

NOTE:

ROOM DIMENSIONS
SHOWN ARE TO
FINISHED WALL FACES.

  

ROOF GARDEN
PARAPET

PARAPET

4

PARAPET

(05 \ PROPOSED PLAN - ROOFTOP

 

YT SCALE 1:100

 

NOTES: AMENDMENTS
1. THIS IS A COMPUTER GENERATED DRAWING, DONOT AMEND BYHAND.| ey pare
2. THIS DRAWING SHOWS DESIGN INTENT ONLY. ALL DIMENSIONS AND
SETOUTS ARE TO BE CHECKED ON SITE PRIOR TO CONSTRUCTION.
3. ANY DISCREPANCIES OR OMISSIONS FOUND WITHIN THE DRAWINGS
ARE TO BE REPORTED TO THE DESIGNER PRIOR TO CONSTRUCTION.
4. DONOT SCALE THIS DRAWING.

COPYRIGHT:
© GT GROUP BUILDING DESIGN. THESE DRAWINGS ARE PROTECTED BY
THE LAWS OF COPYRIGHT AND MAY NOT BE COPIED OR REPRODUCED
WITHOUT THE WRITTEN PERMISSION OF GT GROUP BUILDING DESIGN.

DESCRIPTION

‘A |26.08.2022] ISSUE FOR DEVELOPMENT APPROVAL
B_ | 24.10.2022) DA RFI RESPONSE

ey DA ISSUE

| AUTHOR: GB
| ORIGINAL SHEET SIZE: A3 [420x297mm]

PROJECT

PROPOSED RESIDENTIAL ALTERATIONS

‘ADDRESS

3/30 HASTINGS STREET, NOOSA HEADS QLD 4567

DRAWING

PROPOSED PLAN - LEVEL 2, LEVEL 3 AND ROOFTOP

DRAWING CREATED

SCALE@ AS
1:100
REVISION

AUG 2022

PROJECT NO.

21021 B

DW, NO.

DA005

GT GROUP

 

www.gtgroup.net.qu
[email protected]
era Ie

(07) 3298 6938

 

Used in these records

About this file

File size
7.7 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

2022-10-24 - 3-30 Hastings Street Noosa Heads - DEVELOPMENT APPROVAL RFI RESPONSE.pdf · 7.7 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.