                                For the purpose of measuring and certifying relevant noise conditions and
                                reporting (eg. mechanical plant and equipment, a/c units, motors, refrigeration
                                equipment, compressors, pumps etc ), a suitably qualified person is either:
                                a.      a Registered Professional Engineer of Queensland, or
                                b.      an environmental consultant with a minimum of 3 years current experience
                                        in the field of acoustics.
                              Air
                      30.     Offensive odours, dust, smoke, fumes, particulates, or other contaminants likely to
                              cause a nuisance must not be emitted beyond the boundaries of the premises.
                      31.     Incineration or open burning is not permitted on the premises.
                      32.     When requested by Council, an Air Quality Assessment Report (AQAR)
                              characterising, monitoring and recording of nuisance emissions must be
                              undertaken to investigate any complaint (other than a frivolous or vexatious
                              complaint) caused by odours, dust, smoke, fumes, particulates or other
                              contaminants from operations at the premises.
                      33.     Such monitoring must be undertaken within a reasonable and practicable
                              timeframe nominated by Council and be performed by a suitably qualified person in
                              accordance with relevant guidelines and Standards. The report must be submitted
                              to Council detailing the results of such monitoring and recommendations for control
                              measures to eliminate nuisance air emissions from the operation of the premises.
                              Outdoor Lighting Devices
                      34.     Lighting associated with the use must be designed, sited, installed and tested to
                              comply with Table 2.1 & 2.2 of Australian Standard AS4282-1997 “Control of the
                              obtrusive effects of outdoor lighting” using a control level of 1.
                      35.     Certification must be submitted to Council from a qualified person which certifies
                              that all outdoor lighting devices comply with the requirements of this Decision
                              Notice at the time of commissioning.
                              For the purpose of certifying outdoor lighting devices for the development, a
                              qualified person is:
                              a.       a Registered Professional Engineer of Queensland;
                              b.       an environmental or electrical design consultant with a minimum of 3 years
                                       current experience in the field of outdoor lighting.
                              Waste Disposal
                      36.     The developer must provide waste storage and disposal facilities in accordance
                              with Planning Scheme Policy No. 9 “Waste Management Multi-Dwellings and
                              Commercial and Industrial Premises”. The facilities must include an external
                              impervious area correctly sized for all refuse and recycling containers and suitably
                              screened from public places and neighbouring properties. A bin wash area is
                              required with a cold-water tap, hose and drain outlet connected to sewer, via a
                              bucket trap. The drain outlet must be designed to prevent storm water entry to the
                              sewerage system. This can be achieved with a nib wall 50mm high and up to
                              700mm x 700mm wide (max 0.5m²), or alternatively the waste area can be roofed,
                              or any other design approved by Council.




                                                                                                           Page 5 of 21


Document Set ID: 20278602
Version: 1, Version Date: 22/02/2017                                                              Print Date: 22 February 2017, 1:04 PM

Used in these records

About this file

File size
8.3 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

HRP18103.L02.002_Change application.pdf · 8.3 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.