4,480 3,700 8,590 2,800 5,910 2,300
ENTRY
STAIR VOID VOID
UPPER LEVEL UPPER LEVEL
FFL 15.910 FFL 15.910
DECK LIVING ROOM
FOYER
MAIN LEVEL MAIN LEVEL
FFL 12.970 FFL 12.970
CRAFTS GL
MPR bov e N
<1 M a
ceiling RW RW
POOL DECK NGL
STORAGE STORAGE
LOWER LEVEL POOL LOWER LEVEL
FFL 10.770 FFL 10.770
SECTION E
SCALE 1:100 @ A3 compliant ceiling
<1M above NGL SHADE INDICATES LINE OF CEILING 1M above NGL
1.5m SIDE SETBACK
951 2m SIDE SETBACK
consecutive
edge of 3
storeys
stair
void
over DA4 Development Approval
issue issue / amendment
lift 09.06.22 LF AB JH
6m FRONT SETBACK
shaft
PROPOSED RESIDENCE
over
issue date drawn by
Lot 5 on P9313 client
Ingrid & Nick Hutton
consecutive
EXISTING POOL
edge of 3
storeys
project
section of building Hutton Plover St
location
3 consecutive 24 Plover St Peregian Beach
stories 2m SIDE SETBACK
1.5m SIDE SETBACK
SECTION E
Aboda Lee Foster • director Scott Falconer • director
Design p - 0424 620 247 p - 0431 267 157
Group e - [email protected] e - [email protected]
the aboda design group trust Level 2 1794 David Low Way Coolum Beach,
SHADE INDICATES LINE OF CEILING 1M above NGL ABN 56 266 884 746
t/a aboda design group
Q. 4573. PO box 2449 Noosa Heads Q 4567
• BSA License -150580097 • www.aboda.com.au
compliant ceiling • This drawing is to be read in conjunction with engineers drawings & reports • Construction
to comply with all relevant SAA & NCC Codes & standard Bldg By-law 1975 & as amended •
<1M above NGL
Copyright for design & drawings remain the property of the authors • Verify all dimensions on
3D DIAGRAMMATIC -
site prior to commencement of any works • These drawings are not to be used for scaling.
scale as shown @ A3 issue
drawing no.
LOWER LEVEL- EXTENT OF 3 STOREYS
AND COMPLIANT BASEMENT CEILING
WD.603 DA4
SCALE 1:200 @ A3