               Building Height
               Acceptable Outcome AO5.2 of the High Density Residential Zone Code states:
               AO5.2 Where excavation is required, the maximum portion of the exposed external façade of
                      the building cannot exceed :
                     a) 15 metres in building height for lots with frontage to Serenity Close, Noosa Heads; or
                     b) 12 metres in building height on any other site.
               The applicant is proposing a building height of up to 12.6 metres and does not comply with AO5.2
               of the Hight Density Residential Zone Code. The proposal is therefore required to assessed against
               Performance Outcome PO5 of the High Density Residential Zone Code, which states:

               PO5 Buildings and structures:
                     a) are low rise and present a building height consistent with structures on adjoining and
                         surrounding premises;
                     b) are designed to provide an interesting streetscape and complement landform
                         changes and landscapes;
                     c) do not visually dominate the street or surrounding area;
                     d) respect the scale of existing vegetation, maintaining a vegetated skyline;
                     e) preserve the amenity of surrounding premises including privacy, views and access to
                         sunlight;
                     f) do not exceed three storeys , except for lots with frontage to Serenity Close, Noosa
                         Heads which do not exceed four storeys.
               Assessment
               The proposed development seeks a minor increase in building height above the 12 metre
               maximum as required under AO5.2. The exceedance occurs towards the eastern side of the
               building and includes architectural elements such as contained planters, stairs and handrails
               associated with the rooftop terraces.




                                         Figure 11 – Rooftop terrace height encroachments

               The building includes a substantial 13.2 metre front setback from Elanda Street and presents a
               narrower building façade when compared to other adjoining buildings. The proposed building does
               not dominate the street frontage with the areas of non-compliance not highly visible from publicly
               accessible areas around the building.
               The eastern rear elevation includes an under croft which ensures the eastern external façade does
               not exceed 12 metres.
               The proposal does not adversely impact neighbouring amenity, privacy, or access to sunlight and
               complies with PO5 of the High Density Residential Zone Code.



Document Set ID: 23409043
Version: 7, Version Date: 18/08/2025

Used in these records

About this file

File size
5.5 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Delegated Report - Code - Planning MCU24 0153 & OPW24 0202 (As Published).pdf · 5.5 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.