               The Coastal communities local plan code support buildings and structures which are consistent
               with the ‘beachside character’ of the local plan. Relevant acceptable outcomes support visible roof
               forms which are not concealed behind parapets and do not contain rooftop terraces. Colour
               schemes should include understated colours with low reflective roofing and cladding materials.
               PO7        Buildings, structures and landscaping are consistent with and reflect the beachside
                          character of the local plan area in terms of form, composition and use of materials.
               AO7.5 Buildings are designed to:
                      a)      suit the local subtropical climate;
                      b)      incorporate a mix of lightweight and textured external building materials,
                       including timber finishes with variation provided in texture, detailing and articulation;
                      c)      incorporate verandahs, open balconies with transparent or open balustrades
                       or shaded patios for outdoor living; and
                      d)      allow for landscape integrated with the buildings on site.
               Assessment
               The proposed development’s architecture incorporates a substantial proportion of the building
               material as glazing and coloured masonry finishes.
               While the proposed development could be argued not to incorporate a predominance of lightweight
               building materials as required under AO7.5 of the code, the building’s use of sculptural off form
               concreate and landscape treatments at each level of the building results in a subtropical
               presentation to all street frontages and site boundaries.


               5.     CONSULTATION
               5.1. Referral Agencies
               Not Applicable
               5.2. Internal Council Referrals
               The application was forwarded to the following internal Council officers for review and/or comment:
               •    Development Engineer, Development Assessment –
                    There are outstanding engineering issues that have not been sufficiently addressed.
                    Conceptually the design appears feasible, a preliminary operational works approval can be
                    issued. The proposed external frontage works were sent to the Assets team for review, who
                    were agreeable to the latest plans.
               •    Senior Environment Officer, Development Assessment
                    The application material includes engineering plans that show contiguous piling along the
                    northern and southern side boundaries. An area of natural ground has been provided along the
                    northern boundary between the boundary and the contiguous piles that varies in width for
                    planting in natural ground. Most of the landscape along the southern boundary will be on
                    podium.
                    Conditions have been provided for inclusion within the decision notice.
               •    Infrastructure Planning, Design & Delivery
                    Design Services would recommend conditioning stainless steel handrail in lieu of the existing
                    timber log barrier handrail. The applicants RPEQ engineer will sign off as required by the
                    ramp/stair design.
                    There is no external catchment flowing to the easement however surface flows falling on the
                    concrete path should still be shed off the path by introducing some crossfall. Suggest the
                    applicant provide 1-2% crossfall for the pathway sections uphill of the stairs to shed water to
                    the northern side. This would align well with existing surface inlet. Turf should be adequate
                    scour protection given the minimal flows but adding some plantings to slow down any flows
                    that do concentrate would be beneficial.




Document Set ID: 23409043
Version: 7, Version Date: 18/08/2025

Used in these records

About this file

File size
5.5 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Delegated Report - Code - Planning MCU24 0153 & OPW24 0202 (As Published).pdf · 5.5 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.