Council archive · source document
07/2081 - Operational Works - Landscaping, Carparking & Access, Civil Works, Frontage Works, Stormwater Drainage and Infiltration Pit [As Published] · 142007.2081
“| DRAWING‘SIZE - A2
3%
[om re ee =
RP BOUNDARY
Revision | Description
Data
1
!
i \ H
{ fe) 400 upvc
—000
i KH =e ‘ ‘ |
i Lo ey i, bn AZ i I Hi ta
! I
i pea wa | a cz} fl
i 3 x *
' 3 SUSPEND ORAMAGE FROM x =z
' g BASEMENT SUSPENDED SLAB oO
' i IN ACCORDANCE. WTH AS3500 = nM 1
i | mm bral a
5 (2 | £5
Coy) Ray @ te
a |
i vial}feur I
! |
( 1
t ‘Hot water outlet
: Zh} = +
| Fa 7 = J] Tenperatue/Pressre 1 cad peo
i ' tiniting vahe TB Gee tie
i i " Union stone
3! = i Tot woler lemperatire WAU tog
3) 1 jeontrol devices in an -— / Pesce Ting
' Cy !
eI | ° ; = [ 256 0H Sip
@ i * 277) , i gp N t—-aHo4
: i L_. i i f denies {sedate de
| \ a —_——— — ig vale mount on en
| EXSTING HC8, PLUMBER TO | ig Fe
| CONFIRM LEVELS PRIOIR TO i : jf
{ COWMENONG WORKS L . 4 Safe troy in accordance with
enemas RP BOUNDARY f AS3800.4004.4- 045
, RPD
HOLWATER UNIT DETAIL
SITE ~ LOWER FLOOR PLAN Lot 287 on RP4BII1 | ror
SCALE 1: 100 21 Ferguson street t
Sunshine Beach {
DISCHARGE PIPE ‘SIZE ‘ . Site area 536m2 r
romure_[ oN i }
0 ‘
8 0 \
sa 0
: 100 : ,
SK 50 a Z 2. UZZA 2 T @
u 65 — Bi vel a —
FAG 65 re i ‘
J ir \
f.
svete x >40V é
tes : '
ps : wed/ pwc va
1. lic services shown are diagramotic only. Refer to architectural 2 E
drawings for locations of faxtures. ij .
2. Al Sanltory Hydroutics and Water Reticulation within the allotment ra H hy
boundary to be In accordance with AS3SO0, C50v7 j
3. Al work shall comply with the requirements of authorities having LEGEND P
irisdictlon, after obtaining all necessary permits and opprovats. B Bath — 4 :
4. The contractor is to confirm the position of al) existing services os CO Clean-Out t ‘i
indicated on these and associated plans prior to the commencing of op Rainwater Down—Pipe I {
work, J Expansion doint
5 Stormwater drahoge pipes to 2258 shall be Class SW uPVC HEAVY FP Frog Flap 22 ZIZVIZ .
(U.H.C.) pipe. Over 2258 Concrete Rubber Ring Joint (RRJ) Closs 3. All FWG — Floor Waste Gully | To vented
pipes UN.O. to be lald at a minimum grade of 1 in 100 UNO. volns ore HE Hose Cock o ( 5 3 . , branch
to be constructed In accordance with the manutacturers requirements, HCB —- House Connection Branch I f
6, Sewers 100mm diam. uPVC OW (U.N.0.) and iad at o minimum HR 36m Fire Hose Reel — 11 if ies ,
grode of 1 in 60. HA) Hot Mater Unit 2 J | ls : (SIPS STACK DIAGRAM
7. Water supply pipework below ground is to be ; Ic Inspection Chamber | Kav)
63mm diam. or less - High Density Type 50 a Invert Level 3
Gass 12 Polyethylene 10 Inspection Opening } Issue:
8 Al above ground and intemal water supply plpework to be Type B is hepstn St CONSTRUCTION
Copper, . In [CESOIET
8. Woter services are nol pemnitted in ground sabe and dl ina ond = NRY.—Non-Retum Valve UPPER FLOOR PLAN % i (CONSULTING _ ENGINEERS
Fara aie baad chve the db PLY Presa Litg Y SCALE 1: 100 | SCG situtira’-" civil = yeotecical
10. Fire Hytronts are to be installed are to be installed in accordance PLY Pressure Limiting Valve 1 ABN 40 098 481 899
with AS2419.1, Hose Reels ore to be installed In accordance with AS2441, ‘SC _——_Stop Cock |
11, Clean-outs, inspection opens ad Gsing caps sited Q af ate Level 7 } 18 DUKE STREET SUNSHINE BEACH QLD.4567
vehicular or pedestrian ents are to with either brass or 5447
cast-Iron covers, penn x sn cat f KEY ca = Water Meter. Ph (07) 5447 5544 Fax (07) 2634
12. All inground vdves shall be in cecordonce In approved concrete y eet e ——— ~ UPVC Sewer, size grode and invert cmon - Slormwater pipe, size, grade and invert Title: HYDRAULICS SERVICES
a woste pipes ond water services penetrating slabs to be wrapped B Vanity Basin . tevel oe noted Cis os nated ter ri .
in on opproved flexible jpint joint wrapping. x we at j Torro Exaal Poly Wale Serie, se os roted Sy ty - Fe tet oe Project _21-Ferguson Street
14. The in ‘SERVICE’ refers to the minimum internal pipe diameter WM Washing. Machin —tw— = intend Cold Water service e- = Sanitory!Stack number and Vent size SUNSHINE BEACH, QLD 4567
unless noted otherwise, —_ * 3
—i— = intemal Hot Water senvce —@ ~ Frtre yt oaing 8] Date: June 2007 | DrgNo. 16322-+H1 |
ql
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
07/2081 - Operational Works - Landscaping, Carparking & Access, Civil Works, Frontage Works, Stormwater Drainage and Infiltration Pit [As Published]Related documentApplication case desk ↗
About this file
- File size
- 2.2 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.