Geotechnical Assessment · 142007.743.03

of 12

Text shows just the words. Original shows the document exactly as it was published.

J002100-001-L-Rev0
4 September 2023


Table 1: DCP test results


                                   Blows per 100 mm penetration
   Depth
  (m, BGL)
                            DCP1                              DCP2
   0.0-0.1                   1                                    1
   0.1-0.2                   2                                    2
   0.2-0.3                   3                                    2
   0.3-0.4                   2                                    2
   0.4-0.5                   3                                    1
   0.5-0.6                   3                                    2
   0.6-0.7                   3                                    3
   0.7-0.8                   3                                    3
   0.8-0.9                   4                                    3
   0.9-1.0                   4                                    3
   1.0-1.1                   3                                    3
   1.1-1.2                   4                                    2
   1.2-1.3                   5                                    3
   1.3-1.4                   5                                    4
   1.4-1.5                   5                                    3
   1.5-1.6                   7                                    4
   1.6-1.7                   6                                    3
   1.7-1.8                   6                                    4
   1.8-1.9                   5                                    4
   1.9-2.0                   6                                    4
   2.0-2.1                   5                                    4
   2.2-2.2                   7                                    5
   2.2-2.3                   7                                    5
   2.3-2.4                   8                                    6
   2.4-2.5                   -                                    6
   2.5-2.6                   -                                    5
   2.6-2.7                   -                                    6
   2.7-2.8                   -                                    7
   2.8-2.9                   -                                    7

Existing Structures
The existing structure on site is a single and two level duplex building comprising rendered lightweight board
cladding with a block partition wall between the units (refer Photograph 3 below).

A large manhole was noted on the adjacent lot to the south, however, NC and Unitywater records do not
indicate that either a stormwater or sewer line runs along the rear of the subject site (refer Photograph 4).

All existing nearby structures appeared to be in good structural condition, with no obvious damage visible on
the exterior that may be attributable to slope movement (e.g., no cracking in house walls or concrete
driveway).




                                                        4

Used in these records

About this file

File size
3.4 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Geotechnical Assessment.pdf · 3.4 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.