LEGEND STAGED WORKS
STAGE 1 WORKS AREA - OPW13/0417
STAGE 2 WORKS AREA — OPW13/0616
STAGE 3 WORKS AREA
STAGE 4 & 5 WORKS AREA
ROAD IS TOO FLAT FOR KERB,
2m OFF EDGE OF SHOULDER.
INSTALL TYPE 22 CONCRETE INVERT
TURF EITHER SIDE OF INVERT.
RP20685
+TUBE STOCK
MULCH & REVEGETATION
0.1m DEEP COARSE SAND
TRANSITION LAYER (0.5mm-2mm) ——_—L |
0.15m MINIMUM DEEP S-2mm WASHED SCREENINGS &
SLOTTED RIGID SEEPAGE PIPES & 0.5% MIN GRADE.
LEGEND:
SW
+
+ ee
EXISTING FLOWS TO ADJACENT LOT ARE ATTENUATED TO
PRE-DEVELOPMENT LEVELS BY REMOVING Q5 FLOW TO
BIO-RETENTION BASIN FOR TREATMENT. OVERLAND FLOW
CONTAINED BETWEEN LOTS 39 &40.
NTS
rE
36
SAG PITS TO TAKE Q5, OVERFLOW TO
FLOW PATH BETWEEN LOTS 39/40
sw
sy
INTERLOT STORMWATER PITS |]
TO CATER FOR ADJACENT
LOTS 3 & 4 RP206856
=
a
|
=
A
SW,
5
RP206856
RPI0635EG | BUS STOP_HARDSTAND TO TRANSLINK ’REGULAR STOP”
REQUIREMENTS. 4mx4m CONCRETE HARDSTAND
150mm ABOVE GROUND LEVEL. WIDEN SHOULDER TO
3m WITH TAPERS IN ACCORDANCE WITH TRANSLINK
REQUIREMENTS.
|
—~| 0.80 1.20 ++ 1.00 +++ 1.20 --| FLUSH KERB
TS2000 SAND ROAD EDGE
TOPSOIL & TURF
@8/sqm
LOW POINT OF LOT 5 RP206856,
LOCATION OF FUTURE STORMWATER
DRAINAGE THROUGH LOT 12 RP134343
LINED BIO SWALE
SCALE NTS.
12
RP1 54343
35
Ss
634 3
—_ Lo
&
Tee
<—
ROAD 3 >
STAGE 4
fe %
Cos
6
SP218739
Sp
=
GR
ae
— Faioo
NNN
PROPOSED STORMWATER PIPE
PROPOSED INTERLOT DRAINAGE PIPE WITH
RAINGARDEN
PROPOSED INTERLOT DRAINAGE PIPE
WITH PITS
PROPOSED BIORETENTION BASIN
( Callaghan & Toth )
Civil, Environmental &
Hydraulic Engineers
PO BOX 2305
NOOSA HEADS 4567
8/41 Sunshine Beach Road
Phone 54749081, Fax 54749041
www.callaghanandtoth.com.au
i!
=|
TO TYPICAL DETAIL FIGURE 4.2
designed | ADT datum AHD DERIVED
drawn BM cM
PROPOSED BIORETENTION SWALE TO
PS
checked | AH Origin (B.M.) RL *
TYPICAL SECTION SHOWN BELOW
PROPOSED GULLY PIT WITH
approved
BIORETENTION
EXISTING/PROPOSED FLOW DIRECTION
PROPOSED LAY BACK TYPE KERB M1/M4 TO
IPWEAQ STD DWG R-0080
PROPOSED FLUSH KERB ER2 TO IPWEAQ STD
DWG R-0080
FINAL Q100 FLOOD LINE
EXISTING TOP OF BANK
EXISTING TREE
EXISTING TREE LINE
PREVIOUS ROAD
RESERVE. BDY
SURVEYED _BY
MAX WATTERSION & ASSOCIATES
PHONE 54 426 121
a
(SS
project
PROPOSED 57 LOT SUBDMSION
55 LAKE MacDONALD DRIVE
COOROY
_O————————L—L————,
Client
VALKEV PTY LTD
$d
_O——————————L————,
title
STAGE 4 STORMWATER MASTER
PN
_—_—————————————————————.
LOT 136 on MCH978
Parish of TEWANTIN
County of MARCH
SUNSHINE COAST COUNCIL
Locality of LAKE MacDONALD
Ce )
_—————————————————
SCALE
0 5 10 15 20 25 een 50
scale SCALE SHOWN IS ORIGINAL DRAWING SCALE
1:1000(A3) D0_NOT SCALE FROM THIS DRAWING
USE ONLY DIMENSIONS PROVIDED
REVISIONS
detai
FILES
COMPUTER DIRECTORY
X:\JOBS\CT Projects in progress\1225 30 lots
lake MacDonald Drive\\Design\Current_DWG—BASE
FIGURE 3.1
Sheet 2 of 10 sheets
drawing number
PAGE 10
date 10-3-14
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLarge file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.