20150426 - Engineering Drawings · 132007.2062

Attached to the e-mail OPW16/0050 - Operational Works Application 1 of 2.

of 21

Text shows just the words. Original shows the document exactly as it was published.

Check the original when the exact wording matters.

PROPOSED UNITS

AT

LOT 219 CORSAIR CRESENT

SUNRISE BEACH

FOR:- CONNETIVITY PTY LTD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DRAWING
DESCRIPTION REVISION
NUMBER
Sl COVER PAGE B
S2 FOOTING PLAN A
S3 FIRST FLOOR FRAMING PLAN ¢ UPPER FOOTING PLAN B
S4 SECOND FLOOR FRAMING A
S5 ROOF FRAMING PLAN ¢ MEMBERS SCHEDULE ¢ DETAILS A
Se GROUND FLOOR BRACING PLAN A
s7 FIRST FLOOR BRACING PLAN A
Sé SECOND FLOOR BRACING PLAN A
34 SLAB REINFORCEMENT PLANS @ DETAILS A
slo DETAILS B
Sl DETAILS A
s|2 DETAILS A
S|3 DETAILS A
5|4 DETAILS A
S|5 DETAILS A
Sle DETAILS A
3|7 DETAILS A
sla GENERAL NOTES A
sla CONCRETE NOTES A
S20 BRACING & TIEDOWN DETAILS A
S2l APPENDIX A é B A

 

 

WATERPROOFING OF WALLS AND SLABS IS

 

TO BE TO THE BUILDERS SPECIFICATIONS.

LEGEND

UNO UNLESS NOTED
ICRS CENTRES
MAX MAXIMUM

 

 

HOR HORIZONTA\

i} L
DO NOT SUBSTITUTE Vee VERTICAL
ALTERNATIVE TIMBER BD. | HOLD DOAN
TYPES OR SIZES WITHOUT Fea, SRM eo
ENGINEERS WRITTEN is Not 10 SCALE BREAK
APPROVAL.

OTHERWISE

 

 

 

 

 

R:\rienmacfiles\Rienmac\15\Large\15330 - Lt 219 Corsair Cr, Sunrise Bch - Steve+Dianne Selby - Des Crawford\15330.dwg, Model,
10/03/2016 12:28:36 PM, L Roth, Rienmac Pty Ltd, CutePDF Writer, A3, 1:100

 

 

PETER RIENECKER - RPEQ 2088

This drawing is not to be copied or amended without written
permission from Rienmac Consulting Engineers

NOTES

|. REFER TO APPENDIX A FOR SITE DRAINAGE
REQUIREMENTS AND APPENDIX B FOR SITE
PREPARATION € EARTHWORKS DETAILS.

2. THE MINIMUM ALLOWABLE BEARING CAPACITY AT
UNDERSIDE OF FOOTING BEAMS SHALL BE l00kPa,
UNLESS NOTED OTHERWISE.

3. THE ENGINEER IS TO BE NOTIFIED IF VARIATION
OCCURS BETWEEN SOIL CONDITIONS DURING
CONSTRUCTION AND THAT NOTED ON BORELOGS,
ADVISE ENGINEER IF ROCK IS ENCOUNTERED IN
FOOTING EXCAVATIONS.

4, SLABS TO BE CAST ON 50mm (420mm) LAYER
OF COARSE SAND.

5, MEMBRANE TO BE 0.2mm POLYTHENE (or
EQUIVALENT) LAPPED 200 AT JOINTS, CARRY
DOWN 200mm DOWN FACES DEEP BEAMS,

6. ALL REINFORCEMENT TO BE IN ACCORDANCE WITH
ASI302 AND ASI304,

7. ALL CONCRETE WORK TO BE IN ACCORDANCE WITH
AS3600, Fic = 25MPa,

8. ALTERATION TO SITE CONDITIONS AFTER THE
HOUSE IS COMPLETED BY WAY OF LANDSCAPING,
HOUSE EXTENSIONS OR TREE REMOVAL CAN
EFFECT THE STABILITY OF THE FLOOR SLAB,
THE OWNER SHALL REFER TO THE BUILDER
BEFORE MAKING SUCH CHANGES,

9, ALL WORK NOT OTHERWISE SPECIFIED |S TO BE IN
ACCORDANCE WITH THE AUSTRALIAN DOMESTIC
CONSTRICTION MANUAL, QLD EDITION.

l0, WHERE BRITTLE FLOOR COVERINGS (TILES, ETC)
ARE TO BE USED, SLAB MESH IS TO BE
INCREASE TO F942 FOR THE AFFECTED AREA OR
DELAY FOR MINIMUM OF THREE (3) MONTHS THE
PLACEMENT OF THE FLOOR COVERINGS.

RIENMAC ery ito

ABN. 52 010 666 430 AC.N. 010 666 430
CONSULTING CIVIL &
STRUCTURAL ENGINEERS

SUNSHINE COAST OFFICE:

SUITE 5, FIRST FLOOR, P:- (07) 5478 250d

  

SAINT CIRINO, (07) 5444 |I58
137 BRISBANE ROAD, Email:-info@rienmac. biz
(PO BOX 149) info@rienmac,ne'

MOOLOOLABA @LD_ 4557 Web:— www ,rienmac, bi:

 

CLIENT:
CONNETIVITY PTY LTD
PROJECT:

PROPOSED UNITS

LOT 219 CORSAIR CRESENT
SUNRISE BEACH @LD 4567

REAL PROPERTY DESCRIPTION # COUNCIL:
LOT 219, RP 135364

PARISH OF WEYBA, COUNTY OF MARCH
SUNSHINE COAST REGIONAL COUNCIL
DRAWING TITLE:

COVER SHEET

 

Designed: PLR Drawn: LR

 

SCALES:

 

Engineer: PLR |DATE: 25 MAY I5

 

15330 S|} B

JOB NUMBER DWG No. | ISSUE

 

 

 

 

DO NOT SCALE OFF DRAWINGS. | AS

 

 

 

SHEET | OF 21 |CHECKED: PLR

 
Full text of the other 20 pages

Page 2

DETERMINE EXTENT OF

 

STAIR ON GROUND

NOTE:

co

LOOSE SAND MATERIAL HAS BEEN FOUND TO |600mm DEPTH AT THE
FRONT OF THE SITE AND 2200mm DEPTH AT THE REAR OF THE SITE.

FOLLOWING SITE STRIPPING, THE LOOSE SAND MATERIAL SHALL BE

EXCAVATED IN THE BUILDING AREA UNTIL MEDIUM DENSE SAND IS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AS DETAILED.
RETAINING WALL ON SITE. ENCOUNTERED. THE MATERIAL THEN MAY BE REPLACED IN LAYERS
CJ CJ COMPACTED TO A MINIMUM UNIFORM DENSITY OF_98% TO THE REQUIRED
[E2ZELEEELILITLLLEPEL LE PULL ILLELLLTLDME EEL Zh} "LEVEL. THE DEGREE OF COMPACTION ACHIEVE TO BE TESTED BY A
ia RW3 RWS RECOGNISED AUTHORITY. WITH THE RESULTS. SUBMITTED TO THE
ENGINEER FOR APPROVAL BEFORE CONTINUING,
i CARE TO BE TAKEN TO. ENSURE NO DAMAGE: OCCURS TO NEIGHBOURING
PF \ a PROPERTIES DURING THESE OPERATIONS, ,
[4] a if A
100 SLAB ON GROUND PEI Ir THE BASE OF RW3 FOOTINGS ON THE BOUNDARY |AND SFI FOOTINGS ARE
+0 CCERNAL ApEaS USE FB3 WHERE WIZ TO BE SATURATED AND COMPACTED WITH A VIBRATING PLATE
| LAYER E72 MESH. RETAINING DETAIL IF oo 8 he
30 TOP COVER. PF2 pwiven REQUIRED HERE. (l 7
> | FB3__cJ ea | /
IE Ze 7 Z T ! / | |
Ao r TT my)
ZI | ql | Uf / Ay
xz FALL yy C ee: II | iF y | Is
Ig 1° 4 Ik ile 3
cab = —-L 4 |" N orig e fr =T \ J) | "
| __|$Ter ecole _— ~F |
| pr2 r (oe Il a Py
3 | Sx [ Ll WH — & | Byer I25 SLAB ON GROUND. | LAYER F82 MESH 40
[22] | a ry ft— // | TOP COVER. (TO WATER TANK SLAB AREA
| FB4 FB4 Li | -_-B4 | ONLY).
a a _ L res
SE I45 / 44 -
EE A Te ZA rn
c Ee 7 oO cr : "EBA “A r
L /
Ez | « Lt ly Ql
THIS-PF2 TO EXTEND [E a] | Lf T | — Wht 44 hoo sh
TO MIN 300 PAST U/S z FALL I | gb = ster |
OF POOL EXCAVATION. x | + Fy Lor E Wo = oy Pe J | |
CAT |! 755 (4 : F = t I j | ly 400x200 BLOCK PIER TO SUPPORT FOOTING RIENM AC PTY LTD
| _ lyre 0 Se | ie I | ls BEAMS OVER.WIDEN RW2 FOOTING AS ABN. 82 0l0 666 440 ACN. Olo Gee 430
RI | wo Sea xX FU Wyle / | REQUIRED. CONSULTING CIVIL ¢
Soa Ea § / UCTURAL ENGI
7 xs | jh / | | | STRUCTURAL ENGINEERS
2! \E Lf __ —tt__|—____ ly l/h SUNSHINE COAST|OFFICE:
ty ! [Ez~L_ kJ Pe o£ 1 | | SUITE 5, FIRST #LOOR, P:- (07) 5478 250d
ep FB3 | T CJ Fea, | | SAINT CIRINO, F:- (07) 5444 lI5q
< PF2 / Fe (07) °
—— | = | / ZL 137 BRISBANE ROAD, Email:- [email protected]|
| e a! vl 4 i Ce (PO BOX 149) [email protected]!
L ae | | BK | o FB3 cJ MOOLOOLABA QLD 4557 Web: www,rienmac.bi
J NE io x CLIENT:
cia — —— pri | PFI WW RA CONNETIVITY PTY LTD
=|! ™ = tH | [| feza| Wee PZZZLEZZZZEL LIZZ 1] molec
x POOL AS DETAILED. ~~ a 5 \ PROPOSED WNITS
™ — \
| |
_ Rito T 7
vO Y io 2 2! 2 a! 2 F | LOT 219 CORSAIR CRESENT
Ke Lhe pete pels scat sss ss teat sass =| SUNRISE BEACH QLD 4567
5 2 < r 0 ur Ss
S mts Sg BB we. me 8 5 R & CS ARS BSegToN «cane

FOUNDATION DESIGN IS BASED ON REPORT No, I5Il6l BY GLOBAL TESTING PTY LTD.

REFER TO THIS REPORT FOR SOIL CONDITIONS EXPECTED ON SITE.

IF ACTUAL SOIL

CONDITIONS VARY SIGNIFICANTLY FROM THOSE IN THE REPORT. CONTACT ENGINEER FOR

RE-APPRAISAL OF FOOTING DESIGN.

ALL FOOTINGS TO BE FOUNDED IN MATERIAL OF MINIMUM SAFE BEARING CAPACITY

l00kPa.

ANY FILL MATERIAL BENEATH SLABS IS TO BE COMPACTED IN LAYERS TO

ACHIEVE A MINIMUM UNIFORM DENSITY OF 98% STANDARD COMPACTION.

CONFIRM ALL STEPS AND FALLS WITH ARCHITECTS DRAWINGS.

CJ - FULL HEIGHT CONTROL JOINT TO MASONRY.

R:\rienmacfiles\Rienmac\15\Large\15330 - Lt 219 Corsair Cr, Sunrise Bch - Steve+Dianne Selby - Des Crawford\15330.dwg, Model,

26/11/2015 9:57:06 AM, L Roth, Rienmac Pty Ltd, CutePDF Writer, A3, 1:100

PROVIDE DOWELED ¢ KEYED JOINT BETWEEN POOL
COPING AND SLAB ON GROUND TYPICALLY.

FOOTING PLAN

 

BUILDER TO VERIFY LOCATION OF ALL SERVICES ON SITE PRIOR TO ORDERING MATERIALS

OR COMMENCING WORK. LOCATION OF POOL TO BE VERIFIED ON SITE.

EXCAVATION FOR POOL SHALL NOT EXTEND BELOW A LINE DIPPING AT 45° AWAY FROM
THE NEAREST UNDERSIDE CORNER OF ANY FOOTINGS, CONTACT ENGINEER IF

UNCERTAIN.

 

 

PETER RIENECKER - RPEQ 2088

PARISH OF WEYBA, COUNTY OF MARCH
SUNSHINE COAST REGIONAL COUNCIL

DRAWING TITLE:

 

 

 

 

 

 

 

 

FOOTING PLAN

Designed: PLR Drawn: LR

SCALES: 1:100

Engineer: PLR |DATE: 25 MAY [5
pamsion Hom Riemnec Coiling Engreers [JOB NUMBER DWG No. |_ISSUE
DO NOT SCALE OFF DRAWINGS, | A3 |SHEET 2 OF 21 |CHECKED: — PLR

 

 

 

 

Page 3

CTOR.

STAIR ON GROUND

100 SLAB ON GROUND.

100 SLAB ON GROUND.
| LAYER F72 MESH.
30 TOP COVER.

| LAYER F72 MESH 30 TOP COVER.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  
 
 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
  
 

 

 

SEE DETAILS ON
DRAWING SIO.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 me
WAS NEW 1.5m WIDE FOOTPATH TO
/ Hl COUNCIL SPECIFICATIONS.
Il _
RnI KJ IL
Sa rr
I re r I EXISTING KERB
Hl LE ii J, AND CHANNEL.
| | TJ TJ % CROSSOVER TO BE |IN
CAAT eS lal ACCORDANCE WITH
BPI BL J FBI “1 Al COUNCIL SPECIFICATION.
_ BL__BL CJ
ZI i I [ ZI “2 : 2 pa (125 SLAB)
FALL Bulb uP 400x200 | |=
x <—| BLOK PIER FROM RW2 TJ i °
a | TO SUPPORT FBI ¢ FB2. | 4
|
JA | | y a SS
© a
| 2 i | tf | o
BPI a | y s
B7 Oy 5 |
| eB 2
150
: | al “BE / [023 1] 258 ; in| Soe
° ih PP2 CJ / I] RO LIN 20 FALL, RL. 20.60. J
SE eee ——_ —— — $+ ol A
z y A zo — |
= TO PT a -J ov TJ
0 5B 53 8 2/ S T THIS HEIGHT TO BE
i 4 | / | Bult UP 400x200 | MINIMUM lémm ABOVE —— |
ZEA | <5 250) o/ |] BLOCK PIER FROM RW2 | KERB LEVEL. CONFIRM
BPI At i : | er &/ || TO SWPPORT FBI ¢ FB2. ON SITE. Z
| AG | =
|} a / | 1200 | a
s 8 / 00 ts 100° SLAB ON GROUND.
® | | L/ — er 1 Nearer ee Sesh 30
| IL — S|] ] | TOP COVER, RIENMAC Wry LID
| i 150 3 | | | . L$ A.B.N 52 010 666 430 A.C.N| O10 666 430
k= 50) 2} (iso) | a | 2 CONSULTING CIVIL ¢
b= STRUCTURAL ENGINEERS
BPI BL f BL IF | i
E 1 eee TZ a ae cs | | | | a SUNSHINE COAST| OFFICE
Cd ~T e _ 14 | FBI _- le SUITE 5, FIRST FLOOR, P:- (07) 5478 250d
| woSlea en a je ys SAINT CIRINO, F:- (07) 5444 (15d
a FZZA P77. (7771 (777) i~ 1 137 BRISBANE ROAD, Email:- info@rienmac. biz
| B = id (PO BOX 149) info@rienmac.,ne'
<< |< |? 4 MOOLOOLABA QLD 455 Web:- www. rienmac. bi:
| a“ KE EB 4
CLIENT:
tal__87 butpamyrmm be mma, | CONNETIVITY PTY [LTD
BP2 5 RhI KJ |
v4 _— PROJECT:
1% PROPOSED UNITS
| .
i | _ LOT 219 CORSAIR CRESENT
vs . . — a = - {AI SUNRISE BEACH QLD 4567
° > So ite) ° : S wo o
a & A & gs & SN x os

100 SLAB ON GROUND.

| LAYER F72 MESH.
30 TOP COVER.

FIRST FLOOR FRAMING PLAN ¢

 

 

UPPER FOOTING PLAN

R:\rienmacfiles\Rienmac\15\Large\15330 - Lt 219 Corsair Cr, Sunrise Bch - Steve-Dianne Selby - Des Crawford\15330.dwg, Model,

10/03/2016 12:28:58 PM, L Roth, Rienmac Pty Ltd, CutePDF Writer, A3, 1:100

 

ON DRAWING 55.

 

 

 

REAL PROPERTY DESCRIPTION # COUNCIL:
LOT 219, RP 135364

PARISH OF WEYBA, COUNTY OF MARCH
SUNSHINE COAST REGIONAL COUNCIL
DRAWING TITLE:

FIRST FLOOR FRAMING PLAN
UPPER FOOTING PLAN

 

 

 

 

 

 

 

 

PETER RIENECKER - RPEQ 2088

 

SEE MEMBER SCHEDULE Designed: PLR Drawn: LR
SCALES: 1:100
Engineer: PLR |DATE: 25 MAY 15
permnision fram Rlenmae Coaultng Engreers “| JOB NUMBER DWG No. | ISSUE
DO NOT SCALE OFF DRAWINGS, | A3 |SHEET 3 OF 21 |CHECKED: PLR

 

 

 

 

Page 4

R:\rienmacfiles\Rienmac\15\Large\15330 - Lt 219 Corsair Cr, Sunrise Bch - Steve-Dianne Selby - Des Crawford\15330.dwg, Model,

26/11/2015 9:20:26 AM, L Roth, Rienmac Pty Ltd, CutePDF Writer, A3, 1:100

2/J| CANTILEVER TO
SUPPORT L4.

for]
TIS

BL BL
L3 TIZZA~

JOISTS TO EXTEND TO BLOCK WALL
WITH TRUSSES OVER.

     

TILED WATERPROOF DECK TO BUILDERS
SPECIFICATION FALL FLOOR TO OUTLET.
T

 

TIMBER FRAMED PARAPET TO
| ~~ SUPPORT ON JOISTS.

cl
JI

P11 AIAN

 

TILED WATERPROOF DECK TO BUILDERS
SPECIFICATION FULL HEIGHT TO OUTLET.

SECOND FLOOR FRAMING PLAN

 

 

SEE MEMBER SCHEDULE
ON DRAWING 55,

 

 

 

RIENMAC ery ito

ABN. 52 010 666 430 AC.N. 010 666 430
CONSULTING CIVIL &
STRUCTURAL ENGINEERS

SUNSHINE COAST OFFICE:
SUITE 5, FIRST FLOOR,
SAINT CIRINO, F
[37 BRISBANE ROAD,

(PO BOx 144)
MOOLOOLABA @LD 4557

(07)

P:- (07) 5478 250d

Email:- info@rienmac. biz
[email protected]!
Web:- www.rienmac. bi:

5444 |15q

 

CLIENT:
CONNETIVITY PTY LTD
PROJECT:

PROPOSED UNITS

LOT 219 CORSAIR CRESENT
SUNRISE BEACH @LD 4567

REAL PROPERTY DESCRIPTION # COUNCIL:
LOT 219, RP 135364

PARISH OF WEYBA, COUNTY OF MARCH
SUNSHINE COAST REGIONAL COUNCIL
DRAWING TITLE:

SECOND FLOOR FRAMING PLAN

 

 

 

 

 

 

 

 

PETER RIENECKER - RPEQ 2088

 

 

Designed: PLR Drawn: LR

SCALES: 1:100

Engineer: PLR |DATE: 25 MAY |5
pamsion Hom Riemnec Coiling Engreers [JOB NUMBER DWG No. |_ISSUE
DO NOT SCALE OFF DRAWINGS, | A3 |SHEET 4 OF 21 |CHECKED: — PLR

 

 

 

Page 5

MEMBER SCHEDULE AND NOTES

DESIGN WIND SPEED = WIND CLASSIFICATION N4 - AS94055. 3/100mm No 14 TYPE 17 BATTEN SCREWS
RAFTER.
ALL TIMBER EXPOSED TO THE WEATHER TO BE DURABILITY CLASS 2 OR BETTER. COaTTeN TO BLOCKING PIECE.

 

 

LAMBEAMS € LVL's EXPOSED TO THE WEATHER ARE TO BE PROTECTED IN ACCORDANCE

 

 

 

 

 

 

 

 

 

T ]

WITH MANUFACTURERS SPECIFICATIONS, F i 7 | ! l<——FASICA.

es |
TIEDOWN ENDS OF ALL LINTELS AND ROOF BEAMS WITH I/MI2 ANCHOR ROD, UNO. 4 Ly A.
ALL MEMBERS NOTED AS H3 TREATED ARE TO BE H3 TRU-CORE TREATED. RAFTER OR

TRUSS,

WALL_FRAMING
STUDS - 90x35 MGPI2 STUDS @450 CRS MAX NOT NOTCHED, BLOCKING Noee e CN BATTEN
TOP PLATE - 2/90x35 MGPI2, TIEDOWN WITH MI2 ANCHOR RODS AT ENDS AND @1200 RAFTER UNDER EACH BATTEN. WALL FRAMING,
CRS MAX FOR ROOF SPANS UP TO 4.3m AND @I1200 CRS MAX FOR ROOF SPANS UP TO | FRAMING ANCHOR EACH END.
7.2m,

BOTTOM PLATE - 90x35 MGPI2, STUDS TO BE IN LINE WITH JOISTS OR PROVIDE
SOLID NOGGING IN BETWEEN FOR SUPPORT.

STUDS BESIDE OPENINGS 0 - 2600 2 STUDS
2600 - 4300 3 STUDS JH AN A | M A
4300 - 4500 4 STUDS

>4500 - 75x75x4.0 SHS.

 

BATTENS (METAL ROOF) - 38x75 Fil @900 CRS MAX. 1/l00mm No 14 TYPE |7 SCREW GALV STRAP BRACING NAILED TO TOP OF
TO EACH RAFTER / TRUSS, EACH RAFTER AND LOOPED AT ENDS.

HT - HIP TRUSS,

T - TRUSSES @400mm CRS MAX TO TRUSS MANUFACTURERS SPECIFICATIONS.

    
    

 

BI - 250UB37.

B2 - [50x63 HYSPAN IN PLANE OF JOISTS. JOIST HANGER TO JI.
B3 - 200UB30 IN PLANE OF JOISTS.

B4 - 330x85 17C LAMBEAM.

B5 - 260x85 17C LAMBEAM H3 TREATED.

Bé - 130x65 17¢ LAMBEAM H3 TREATED.

B7 - 240x63 HYSPAN IN PLANE OF JOISTS, JOIST HANGER TO 3.
B& - 295x85 17C LAMBEAM.

Ba - 230x85 17C LAMBEAM H3 TREATED IN PLANE OF JOISTS.

| BATTENS CANTILEVER AS

a DETAILED.

Ll

L3

BL - MIN 300 DEEP BLOCK LINTEL WITH 2/NI2 HORIZONTAL BARS TOP ¢ BOTTOM.

BPI - 600x190 BLOCK PIER,
BP2 - 400xl90 BLOCK PIER,

  
    

R

Cl - 89x89x5.0 SHS COLUMN.

DOUBLE JOISTS UNDER ALL LOADBEARING WALLS, UNO,

DJ - DOUBLE JOISTS,

Jl - 150x%45 HYSPAN JOISTS @450 CRS MAX.

J2 - 170x 45 HYSPAN JOISTS @450 CRS MAX. H3 TREATED WITH TILED WATERPROOF
DECK TO BUILDER SPECIFICATIONS,

J3 - 240x45 HYSPAN JOISTS @450 CRS MAX,

J4 - 150x45 HYSPAN JOISTS H3 TREATED @450mm CRS MAX WITH TILED WATERPROOF
DECK TO BUILDER SPECIFICATIONS.

 

RB2 UNDE

    
   

NOTE: BLOCKWALL TO EXTEND TO U/S OF RIENMAC PTY LTD

ROOF SHEETING FOR FIRE SEPARATION, ABN. 52 010 666 430 A.C.N. 010 666 430
CONSULTING CIVIL €&
STRUCTURAL ENGINEERS

SUNSHINE COAST OFFICE:
SUITE 5, FIRST FLOOR, P:- (07) 5478 250d
SAINT CIRINO, F:- (07) 5444 {158

vu
Uv

 

ALL LINTELS ARE HYSPAN, UNO.

 

 

 

LI - DOUBLE TOP PLATE. L2 - 90x63. L3 - [30x63 L4 - 150x063 (oo oat) ROAD, Email: info@rienmac. biz
L5 - 170x63 L@ - 200x63 [email protected]'
MOOLOOLABA QLD 4557 Web:- www ,rienmac.bi
PPI - 200x45 HYSPAN POLE PLATES IN PLANE OF RAFTERS. MI2 CHEMICAL ANCHORS CLIENT:
TO BLOCKWALL AT ENDS ¢ 1200mm CRS MAX. GALV STRAP BRACING NAILED TO TOP OF EONNETIVITY PTY LTD

PP2 - 240x45 MGPI2 POLE PLATE IN PLANE OF JOISTS, 2/MI2 CHEMICAL ANCHORS TO EACH RAFTER AND LOOPED AT ENDS,

BLOCKWALL AT ENDS € @600mm CRS. JOIST HANGERS TO J3.
PP3 - 50x45 HYSPAN POLE PLATE. MI2 CHEMICAL ANCHORS TO BLOCKWALL AT ENDS @
@600mm CRS.

PROJECT:

PROPOSED UNITS

LOT 214 CORSAIR CRESENT
LBW - LOADBEARING WALL. SUNRISE BEACH QLD 4567

RI - 200x45 HYSPAN PURLINS @400mm MAX. | FRAMING ANCHOR EACH SUPPORT.

RBI - 230x85 17C LAMBEAM IN PLANE OF UPPER RAFTERS.
RB2 - 200x45 HYSPAN IN PLANE OF LOWER RAFTERS SUPPORTED BY RBI & REAL PROPERTY DESCRIPTION € COUNCIL:

BLOCKWALL.
; LOT 219, RP 135364
RB3 - 200x63 HYSPAN IN PLANE OF RAFTER. PARISH OF WEYBA, COUNTY OF MARCH
SUNSHINE COAST REGIONAL COUNCIL
DRAWING TITLE:

ROOF FRAMING PLAN
MEMBERS SCHEDULE ¢ DETAILS

ROOF FRAMING PLAN Designed PLR Draune UR

SCALES: 1:100, 1:20
Engineer: PLR |DATE: 25 MAY I5

15330 55) A

passant Riowmee Corsling Engraers "| JOB NUMBER DWG No, | ISSUE
PETER RIENECKER - RPEQ 2088 | | Do NoT SCALE oFF DRAWINGS, | A3 |SHEET 5 OF 21 |CHECKED: PLR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R:\rienmacfiles\Rienmac\15\Large\15330 - Lt 219 Corsair Cr, Sunrise Bch - Steve-Dianne Selby - Des Crawford\15330.dwg, Model,
26/11/2015 9:20:39 AM, L Roth, Rienmac Pty Ltd, CutePDF Writer, A3, 1:100

Page 6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[LLL LLL EL EEE LEME LIE EL OLE EL ENOL EP EAL EEE =}
[4] [eea) peace Zara
iI
i J
=e
= -— 4]!
pa == ay
| mil | ap
: | on le
| He 14 iW
- ——4 Pu ye
| BLOCK WALL =u gy i
! eA are
[2] | Pr—14 | !
_ J Ll oe Lind fe
LL_LELEE LETZTE LETELIZ MLE GS A L
qT TTT TOT TTT TTA TI7 —— rc
pea | Ll Ly |
Ea | it = Ad 1
) In=vja_
+ — I n=)
| tg We
| | |
TEs ee]
t~ i | | |
Le pi dasas scart Nyt L
| | | nt ++)
| | | ri
H- | 1
[za] | [eal Were epee ZZ ZZZZPEIEL |
| \
| |
>) I |
J ee 5 .

BRACING NOTES

—_—-_

- INDICATES BRACING WALL AND ANCHOR RODS.

 

 

|.2P INDICATES PLYWOOD NAILED TO STUDS AS PER METHOD A OF ASIG84
TABLE 8.18(h) AND HOLD DOWN WITH ANCHOR RODS AT EACH END TO ACHIEVE

6.4KN/m BRACING STRENGTH.

BR - Mlé CROSS ROD BRACING [email protected] EACH.

BRACING DETAILS AS PER ASI684 - PART 2 FOR N3 WIND CLASSIFICATION,

ALL BRACING WALLS ARE TO BE CONNECTED TO THE CEILING FRAMING AS PER

ASI684 TABLE 8.22 TO TRANSFER THE DESIGNATED FORCES,

R:\rienmacfiles\Rienmac\15\Large\15330 - Lt 219 Corsair Cr, Sunrise Bch - Steve+Dianne Selby - Des Crawford\15330.dwg, Model,

26/11/2015 9:20:53 AM, L Roth, Rienmac Pty Ltd, CutePDF Writer, A3, 1:100

'e' ANCHOR ROD LOCATIONS

AS PER ASI684 FOR BRACING
WALLS ONLY.

 

 

PETER RIENECKER - RPEQ 2088

 

 

FORCE REQ'D = |82kN
PROVIDED = 203kN

FORCE REQ'D = 204kN
PROVIDED = 2/2kN

RIENMAC ery ito

ABN. 52 010 666 430 AC.N. 010 666 430
CONSULTING CIVIL &
STRUCTURAL ENGINEERS

SUNSHINE COAST OFFICE:
SUITE 5, FIRST FLOOR,
SAINT CIRINO,

[37 BRISBANE ROAD,

(PO BOx 144)
MOOLOOLABA @LD 4557

P:- (07) 5478 250d
F:- (07) 5444 lI58
Email:- info@rienmac. biz
[email protected]!

Web:- www.rienmac. bi:

 

CLIENT:
CONNETIVITY PTY
PROJECT:

PROPOSED UNITS

LOT 219 CORSAIR CRESENT

LTD

SUNRISE BEACH @LD 4567

REAL PROPERTY DESCRIPTION # COUNCIL:
LOT 219, RP 135364

PARISH OF WEYBA, COUNTY OF MARCH
SUNSHINE COAST REGIONAL COUNCIL
DRAWING TITLE:

GROUND FLOOR BRACING PLAN

 

 

 

 

 

 

Designed: PLR Drawn: LR

SCALES: 1:100

Engineer: PLR |DATE: 25 MAY [5
pamsion Hom Riemnec Coiling Engreers [JOB NUMBER DWG No. |_ISSUE
DO NOT SCALE OFF DRAWINGS, | A3 |SHEET 6 OF 21 |CHECKED: — PLR

 

 

 

 

Page 7

 

 

 

 

 

 

 

 

FORCE REQ'D = l0GkKN

Zz
vv
So
SS] Zz
— |]
N
Nib
QO] ,
S
um) a
Y} uw
WIS
z|9
ele

PROVIDED = I08kN

BLOCK WALL PROVIDES 2IkN IN
THIS DIRECTION.

 

 

 

SE SS
Q, Bo Bo
| Tho. ZA [eZ Zz
0.9P 0.9 0.97 We ee || “q
| Za r o |
o
“
S +
x |
| a
qs SS S55 555>—=—9 SS |
| & [
| N =
- | BLOCK WALL PROVIDES 36kN IN
a | THIS DIRECTION, —_
| |
L | BY50 |
L A: A
u I
|
ZZ | Cc
| b=
| & —
| N
g
Pa a

 

 

\

PITTt in

Lb oe ey Ke,
OOP OaP°

 

FIRST FLOOR BRACING PLAN

BRACING NOTES

- INDICATES BRACING WALL AND ANCHOR RODS.

—

1.2P INDICATES PLYWOOD NAILED TO STUDS AS PER METHOD A OF ASI684

TABLE 8,.I8(h) AND HOLD DOWN WITH ANCHOR RODS AT EACH END TO ACHIEVE

6.4KN/m BRACING STRENGTH,

'e' ANCHOR ROD LOCATIONS
AS PER ASI684 FOR BRACING
WALLS ONLY.

BR - Mlé CROSS ROD BRACING [email protected] EACH.

BRACING DETAILS AS PER ASI@84 - PART 2 FOR N3 WIND CLASSIFICATION.

 

ALL BRACING WALLS ARE TO BE CONNECTED TO THE CEILING FRAMING AS PER
ASIG84 TABLE 8,22 TO TRANSFER THE DESIGNATED FORCES.

 

 

PETER RIENECKER - RPEQ 2088

 

R:\rienmacfiles\Rienmac\15\Large\15330 - Lt 219 Corsair Cr, Sunrise Bch - Steve-Dianne Selby - Des Crawford\15330.dwg, Model,
26/11/2015 9:21:06 AM, L Roth, Rienmac Pty Ltd, CutePDF Writer, A3, 1:100

 

 

RIENMAC ery ito

ABN. 52 010 666 430 AC.N. 010 666 430
CONSULTING CIVIL &
STRUCTURAL ENGINEERS

SUNSHINE COAST OFFICE:
SUITE 5, FIRST FLOOR, P:- (07) 5478 250d
SAINT CIRINO, F:- (07) 5444 {158
137 BRISBANE ROAD, Email:-info@rienmac. biz
(PO BOX 149) info@rienmac,ne'
MOOLOOLABA QLD 4557 Web:- www ,rienmac.bi

 

CLIENT:
CONNETIVITY PTY LTD
PROJECT:

PROPOSED UNITS

LOT 219 CORSAIR CRESENT
SUNRISE BEACH @LD 4567

REAL PROPERTY DESCRIPTION # COUNCIL:
LOT 219, RP 135364

PARISH OF WEYBA, COUNTY OF MARCH
SUNSHINE COAST REGIONAL COUNCIL
DRAWING TITLE:

FIRST FLOOR BRACING PLAN

 

 

 

 

 

 

Designed: PLR Drawn: LR

SCALES: 1:100

Engineer: PLR |DATE: 25 MAY |5
pamsion Hom Riemnec Coiling Engreers [JOB NUMBER DWG No. |_ISSUE
| DO NOT SCALE OFF DRAWINGS, | A3 |SHEET 7 OF 21 |CHECKED: — PLR

 

 

 

 

Page 8

SECOND FLOOR BRACING

BRACING NOTES
- INDICATES BRACING WALL AND ANCHOR RODS.

|.2P INDICATES PLYWOOD NAILED TO STUDS AS PER METHOD A OF ASI684
TABLE 8,.18(h) AND HOLD DOWN WITH ANCHOR RODS AT EACH END TO ACHIEVE
6.4kN/m BRACING STRENGTH.

BR - Mlé CROSS ROD BRACING [email protected] EACH.

BRACING DETAILS AS PER ASIG84 - PART 2 FOR N3 WIND CLASSIFICATION,
ALL BRACING WALLS ARE TO BE CONNECTED TO THE CEILING FRAMING AS PER
ASI684 TABLE 8.22 TO TRANSFER THE DESIGNATED FORCES.

R:\rienmacfiles\Rienmac\15\Large\15330 - Lt 219 Corsair Cr, Sunrise Bch - Steve-Dianne Selby - Des Crawford\15330.dwg, Model,
26/11/2015 9:21:23 AM, L Roth, Rienmac Pty Ltd, CutePDF Writer, A3, 1:100

 

 

 

 

 

 

 

 

| fi TeP
i
oo)
| if a |
|
| |
| 0
! |
fo
| * [Z|

x —

 

LeP

 

 

 

 

 

 

 

'e' ANCHOR ROD LOCATIONS
AS PER ASI684 FOR BRACING

WALLS ONLY.

 

FORCE REQ'D = 36kN
PROVIDED = 38kN

PLAN

 

 

PETER RIENECKER - RPEQ 2088

54kKN

FORCE REQ'D = 42kN

PROVIDED

This drawing is not to be copied or amended without written
permission from Rienmac Consulting Engineers

RIENMAC ery ito

ABN. 52 010 666 430 AC.N. 010 666 430
CONSULTING CIVIL &
STRUCTURAL ENGINEERS

SUNSHINE COAST OFFICE:
SUITE 5, FIRST FLOOR, P:- (07) 5478 250d
SAINT CIRINO, F:- (07) 5444 {158
137 BRISBANE ROAD, Email:-info@rienmac. biz
(PO BOX 149) info@rienmac,ne'
MOOLOOLABA QLD 4557 Web:- www ,rienmac.bi

 

CLIENT:
CONNETIVITY PTY LTD
PROJECT:

PROPOSED UNITS

LOT 219 CORSAIR CRESENT
SUNRISE BEACH @LD 4567

REAL PROPERTY DESCRIPTION # COUNCIL:
LOT 219, RP 135364

PARISH OF WEYBA, COUNTY OF MARCH
SUNSHINE COAST REGIONAL COUNCIL
DRAWING TITLE:

SECOND FLOOR BRACING PLAN

 

Designed: PLR Drawn: LR

 

SCALES: 1:100

 

Engineer: PLR |DATE: 25 MAY I5

 

15330 58| A

JOB NUMBER DWG No. | ISSUE

 

 

 

 

DO NOT SCALE OFF DRAWINGS. | AS

 

SHEET 8 OF 21 |CHECKED: PLR

 

 

 

Page 9

 

 

 

NI2 @200

sh

O/NI2
@l0o

I

 

NI2 @200

 

[|
V1
TT
Wi
{fo LC LC LC eC LN CLL

 

 

 

 

 

 

 

[1

 

 

Ni2 @200

 

O/NI2
@l0Q

Ni2 @200

 

COLT TTT

 

 

 

 

 

 

 

 

BOTTOM REINFORCING PLAN

ALL BARS ARE NI2, UNO, fone ?
C LAYER D LAYER

BARS @300 CRS, UNO.

BARS IN THIS DIRECTION TO BE

OUTERMOST ...ccescsccsssecsssessaseessvees —_
Cg SD

LAPS NI2 - 500

NIG - 650 A LAYER B LAYER

R:\rienmacfiles\Rienmac\15\Large\15330 - Lt 219 Corsair Cr, Sunrise Bch - Steve-Dianne Selby - Des Crawford\15330.dwg, Model,
26/11/2015 9:21:36 AM, L Roth, Rienmac Pty Ltd, CutePDF Writer, A3, 1:100

   

ZA [ZA

 

 

 

 

 

 

 

 

 

 

 

 

       
   

LAP

LENGTH 300 COG. LAP WITH

BOTTOM REINF'T.

TYPICAL TOP REINFORCEMENT
ARRANGEMENT

 

   

 

 

 

 

 

 

 

_ H | REE
i REINF'T. LENGTH
:
id =4}-4 TYPICAL BOTTOM REINFORCEMENT
- | ARRANGEMENT
a al

 

 

 

 

it ttt\
Ni2 @300., @|0¢

 

 

 

 

 

 

 

 

TOP REINFORCING PLAN

 

RIENMAC ery ito

ABN. 52 010 666 430 AC.N. 010 666 430
CONSULTING CIVIL &
STRUCTURAL ENGINEERS

SUNSHINE COAST OFFICE:

SUITE 5, FIRST FLOOR, P:- (07) 5478 250d

SAINT CIRINO, F:- (07) 5444 {158
137 BRISBANE ROAD, Email:-info@rienmac. biz
(PO BOX 149) info@rienmac,ne'

MOOLOOLABA @LD_ 4557 Web:— www ,rienmac, bi:

CLIENT:
CONNETIVITY PTY LTD
PROJECT:

PROPOSED UNITS

 

LOT 219 CORSAIR CRESENT
SUNRISE BEACH @LD 4567

REAL PROPERTY DESCRIPTION # COUNCIL:
LOT 219, RP 135364

PARISH OF WEYBA, COUNTY OF MARCH
SUNSHINE COAST REGIONAL COUNCIL
DRAWING TITLE:

SLAB REINFORCEMENT PLAN

 

 

 

 

 

 

 

 

PETER RIENECKER - RPEQ 2088

 

 

 

DETAILS

Designed: PLR Drawn: LR

SCALES: 1:100, 1:20

Engineer: PLR |DATE: 25 MAY [5
permnision fram Rlenmae Coaultng Engreers “| JOB NUMBER DWG No. | ISSUE
DO NOT SCALE OFF DRAWINGS. | AS |SHEET 9 OF 21 |CHECKED: PLR

 

 

Page 10

BOLSTER CUT SLAB (3Wx30D), FILL
JOINT TO 30mm BELOW SURFACE WITH
FOSROC EXPANDITE THIOFLEX 600G.

| LAYER F72 FABRIC.
30 TOP COVER.

FORM KEY IN EDGE OF Ist POURED SLAB COAST
FACE OF SLAB WITH BOND PREVENTATIVE.

 

 

     

 

 

 

L $.0.G | é |
SO 3 ———————S
gS —- 5S
3S SSS SS St == ——$—$—
SP LE YS SOON yyy)

300 SUBGRADE TO BE COMPACTED TO 98%

EDGE THICKENING (ET)

 

STANDARD COMPACTION (TEST El.! ASI284).

TOOLED JOINT (TJ)

CUT EVERY 2nd WIRE DIRECTLY UNDER

(eg, HYDROSEAL, FORMOIL).

25

 

00.
100

 

 

OY

 

JOINT € DEPRESS FABRIC LOCALLY.

 
 

 

  
 

3 BAR FIITM.
50 BOTTOM COVER,

KEYED JOINT (KJ)

 

 

TYPICAL TO ALL EDGES OF DRIVEWAY SLAB.
DISCONTINUE FABRIC 40mm FROM END.

DRIVEWAY NOTES:

|, EXISTING FOOTPATHS TO BE SAW CUT PRIOR TO REMOVAL.
2, CROSSINGS ARE NOT DESIGNED FOR COMMERCIAL VEHICLES.
3

CONCRETE DRIVEWAY TO BE [25mm THICK EXCLUDING ANY FINISH TREATMENTS. eg.

STAMPED CONCRETE FINISH.

ALTERNATIVELY: SAW CUT SLAB 3Wx30D WITHIN
24 HOURS OF CASTING SEAL AS ABOVE.

DRIVEWAY SLAB ON GROUND DETAILS

CONCRETE SURFACE TOLERANCE TO BE 0-5mm, OVER 3 METRE SECTIONS.

CONCRETE N25 IN ACCORDANCE WITH ASI374 AND AS3600.

APPROVED MATERIALS FOR CONSTRUCTION:- CONCRETE or ASPHALT.

4
5.
6, REINFORCEMENT FABRIC TO ASI304, 50 TOP AND EDGE COVER, LAP FABRIC 250.
7
&

EXPANSION JOINTS TO BE lOmm WIDE, FULL DEPTH CLOSED CELL CROSS LINKED
POLYETHYLENE FOAM (85-150kg/m3) OR COMPRESSED GRANULATED CORKBOARD,

INSTALLATION TO MANUFACTURERS INSTRUCTIONS.
9, ALL DIMENSIONS IN MILLIMETERS.

lOmm CORKJOINT OR
SIMILAR.

  

SOY

10. ONE ACCESS POINT TO BE CONSTRUCTED TO EACH LOT AS PER STANDARD DRAWING.
ll, FOR CURVED DRIVEWAYS, MAXIMUM GRADES APPLY TO INSIDE EDGE OF CURVE.

I2. ALL SERVICES NEED TO BE LOCATED PRIOR TO EXCAVATION.

 

190 BLOCKWALL

\erP

NI2 VER BARS @400 CRS. LAP
500 WITH NI2 FROM FOOTING.———7-*|
NI2 HOR BARS @400 CRS. LAP

 

 

 

 

 

 

x
450 WHERE REQ'D AND AT =
CORNERS. 2 Q

N
|O
3 BAR F8TM TOP ¢
BOTTOM, RIO LIGS
@600 CRS. L
KK KK
a
NOT TO BE USED FOR
RETAINING, USE RW3. 8
3

 

 

 

Q 9 oO

SFl DETAILS

R:\rienmacfiles\Rienmac\15\Large\15330 - Lt 219 Corsair Cr, Sunrise Bch - Steve-Dianne Selby - Des Crawford\15330.dwg, Model,
10/03/2016 12:29:14 PM, L Roth, Rienmac Pty Ltd, CutePDF Writer, A3, 1:100

 

 

 

 

BARRIER/SEMI-MOUNTABLE
KERB AND CHANNEL. 7}

CONSTRUCTION
JOINT.

MOUNTABLE KERB

AND CHANNEL.

FOOTPATH

       

0
=
PROPERTY BOUNDARY

2
Ss

NONSLIP =
FINISH, s
S
RK

0 MAX

Ss
re)
10

 

  

1000

 

 

 

N_

 

FOOTPATH

ALTERNATIVE PROFILE.

DRIVEWAY

CROSSING PLAN

 

   

BOLSTER CUT SLAB (3Wx30D).

 

DIY

QP”.

 

100 SLAB ON GROUND TO PATH. | LAYER F72 MESH 30 TOP

COVER, 50 SIDE AND END COVER. PROVIDE:

- TOOLED JOINTS (TJ) @2m CRS MAX.
- KEYED JOINTS (KJ) @6m CRS MAX,
- EXPANSION JOISTS (EJ) @lém CRS MAX,

| LAYER F72 MESH
30 TOP COVER.

SPY ~

X

CUT EVERY 2nd WIRE DIRECTLY UNDER
JOINT € DEPRESS FABRIC LOCALLY.

EXPANSION JOINT (EJ) TOOLED JOINT (TJ)

ALTERNATIVELY: SAW CUT SLAB 3Wx30D WITHIN

24 HOURS OF CASTING.

PATH SLAB DETAILS

(TO BE FOUNDED ON MATERIAL OF
CAPACITY |00kPa. )

DRIVEWAY DETAILS AND
NOTES TAKEN FROM COUNCIL
RESIDENTIAL DRIVEWAY
DRAWING R-0050.

NOMINAL
KERB LINE

N

a

  

 

MIN SAFE BEARING

 

APPROVED PREFORMED
METAL KEY JOINT,

 

KEYED JOINT (KJ)

RIENMAC ery ito

ABN. 52 010 666 430
CONSULTING CIVIL &
STRUCTURAL ENGINEERS

SUNSHINE COAST OFFICE:
SUITE 5, FIRST FLOOR,
SAINT CIRINO, F
[37 BRISBANE ROAD,

(PO BOx 144)
MOOLOOLABA @LD 4557

A.C.N. 010 666 430

P:- (07) 5478 250d
(07) 5444 |I5q
Email:- info@rienmac. biz
[email protected]!

Web:- www.rienmac. bi:

 

     
  

 

at, ET ¢z|

     
 

TR

 

FRX.

SAND BED,

CLIENT:
CONNETIVITY PTY LTD

F72 MIN FABRIC PROJECT:
PROPOSED UNITS

LOT 219 CORSAIR CRESENT
SUNRISE BEACH @LD 4567

REAL PROPERTY DESCRIPTION # COUNCIL:
3 LOT 219,

PARISH OF WEYBA, COUNTY OF MARCH
SUNSHINE COAST REGIONAL COUNCIL

RP 135364

 

 

 

 

 

 

 

 

 

 

BARRIER, SAW CUT AND BREAKOUT DRAWING TITLE:
SEMI-MOUNTABLE, BACK OF KERB AND DETAILS
MOUNTABLE KERB ¢ CHANNEL.
CHANNEL OR INVERT
CROSSING. Designed: PLR Drown: LR
DRIVEWAY. SCALES: 1:20
CROSSING DETAI L Engineer: PLR |DATE: 25 MAY [5
5330 SIO} B
Fe ee Rita Coating Paros tat written | JOB NUMBER DWG No, | ISSUE
PETER RIENECKER - RPEQ 2088 | DO NOT SCALE OFF DRAWINGS. | A3 |SHEET lo OF 21 |CHECKED: PLR

 

 

 

 

 

Page 11

   
  

INTERSECTION CORNE
EDGE BEAM

RIO TIES @600 CRS.

 

LAP TRENCH MESH

 

FULL WIDTH

 

 

450
———>

 

 

 

 

 

 

 

 

 

 

 

EXTRA NI2
TOP AND BOTTOM

EDGE

CONSTRUCTION BREAK.

R

3/NI2 Z BARS EACH
FACE 400 LEGS,

 

 

50 SAND BED AND

300
MAX
“x

 

 

 

 

 

 

 

 

 

 

 

|
FOOTING STEP

 

   

WATERPROOF MEMBRANE.

3 BAR FIITM.
50 BOTTOM COVER.
RIO TIES @600 CRS.

E.B. DETAILS

| LAYER F72 FABRIC.
30 TOP COVER.

F.S.L

 

 

 

 

 

 

BEAM

F72 FABRIC TOP

 

 

 

 

 

ALTERNATE DIRECTION. |. 400 LAP 30 COVER.
,9.0.G. a |
g L J 1
RKEG CRAG g
8 50 SAND BED. | 3 BAR FIITM. °
WATERPROOF | 50 COVER.
*— MEMBRANE - TYPICAL. - —
350
50 MIN 50 MIN

 

 

 

 

BEAM FB2

  

 

DETAILS

FB5 DETAILS

F72 FABRIC TOP
30 COVER.

3 BAR FIITM.
50 BTM COVER. °

S
S

250

 

300

EXTRA 2/NI2 BARS (OR 3 BAR F8TM)
DIAGONALLY ACROSS ALL CORNERS OF
RECESSES AND VOIDS.

  

MAX

00 20

 

 

IF FB2 IS NOT POURED INTEGRALLY
WITH EDGE BEAM, PROVIDE 2/NI2
BARS LAPPED 400 WITH BOTTOM
TRENCH MESH.

 

 

 

 

AT BEAM LOCATIONS 2/RIO
TIES @600 CTS. BENT INTO
SLAB. LAP 400 WITH FABRIC
MAINTAIN 30 TOP COVER CONSTRUCTION BREAK.
WITH FABRIC. F72 FABRIC
TOP 30 COVER.
C 5.0.G. |
— Yo +“
F.S.L.
oS NA
PERIMETER | === IN 4

 

  

 

LN

L|

 

 

 

 

FOOTING.
\7

 

VNTR 1
3

L
IRS
BARS FIITM BTM TO BEAM FB2.

END WITH CROSS WIRE.

 

 

 

FOOTING BEAM FB2 TO

 

PERIMETER FOOTING

 

R:\rienmacfiles\Rienmac\15\Large\15330 - Lt 219 Corsair Cr, Sunrise Bch -
26/11/2015 9:22:04 AM, L Roth, Rienmac Pty Ltd, CutePDF Writer, A3, 1:100

Steve+Dianne Selby - Des Crawford\15330.dwg, Model,

  
    
   
   
   

3 BAR FIITM
50 EDGE COVER
2000 LONG

EDGE OF FOOTING

EDGE OF SLAB

 

PROVIDE ALSO AT
CORNERS OF ALL
RECESSES AND
VOIDS

SLAB _RE-ENTRANT
CORNER DETAIL

TYPICAL FOR ALL CORNERS OF ALL RECESSES AND VOIDS

 

 

 

RIENMAC ery ito

ABN. 52 010 666 430 AC.N. 010 666 430
CONSULTING CIVIL &
STRUCTURAL ENGINEERS

SUNSHINE COAST OFFICE:

SUITE 5, FIRST FLOOR, P:- (07) 5478 250d

SAINT CIRINO, F:- (07) 5444 {158
137 BRISBANE ROAD, Email:-info@rienmac. biz
(PO BOX 149) info@rienmac,ne'

MOOLOOLABA @LD_ 4557 Web:— www ,rienmac, bi:

 

CLIENT:
CONNETIVITY PTY LTD
PROJECT:

PROPOSED UNITS

LOT 219 CORSAIR CRESENT
SUNRISE BEACH @LD 4567

REAL PROPERTY DESCRIPTION # COUNCIL:
LOT 219, RP 135364

PARISH OF WEYBA, COUNTY OF MARCH
SUNSHINE COAST REGIONAL COUNCIL
DRAWING TITLE:

 

 

 

 

 

 

 

 

PETER RIENECKER - RPEQ 2088

 

 

DETAILS

Designed: PLR Drawn: LR

SCALES: 1:20

Engineer: PLR |DATE: 25 MAY I5
parmissin fram Riownee Corsling tngraers | SOB NUMBER DWG No. | ISSUE
DO NOT SCALE OFF DRAWINGS. | A3 |SHEET Il OF 21 |CHECKED: PLR

 

 

 

Page 12

NOTES:

PROVIDE CLEAN OUT BLOCKS TO THE BASE OF ALL WALLS.

- FOOTINGS ARE TO BE FOUNDED IN MATERIAL OF MINIMUM SAFE BEARING CAPACITY l00kPa.

- ALL BLOCKWORK MATERIALS AND WORKMANSHIP SHALL BE IN ACCORDANCE WITH AS3700 € F'uc = I5MPa,

- MORTAR TO BE IN ACCORDANCE WITH AS Al23 € SHALL BE MIXED IN THE FOLLOWING PROPORTIONS:
CEMENT |; HYDRATED LIME % CLEAN PIT SAND 4%,

- CONCRETE TO FOOTINGS F'c = N25,

- GROUT FILL TO BLOCK WALL F'c = 20MPa, SLUMP = 225mm, MAX AGG. SIZE = 5mm.

- GROUT FILL TO BE RODDED USING A PLAIN ROUND BAR,

- DO NOT PLACE BACKFILL BEHIND RETAINING WALL UNTIL MINIMUM TEN DAYS AFTER GROUTING,

WALLS UP_TO 2.0m HIGH

 

 

 

 

 

 

 

 

c”

BLOCK WALL.

 

 

 

 

 

4+ Nl@ IN TOP COURSE.

| PROVIDE GRANULAR BACKFILL ¢€ AGG DRAIN WRAPPED
_=—|_IN GEOFABRIC SOCK, CONNECTED TO SW LINE BEHIND
| ALL RETAINING WALLS. SLOPE DRAIN | IN 100.

| tS NI2 @400mm. 55 COVER,

 

TL NI2 @400mm LONGITUDINALLY
LAP 450 WHERE REQUIRED AND

 

 

 

AT CORNERS.

'V' BARS WITH 55 COVER -

Tt LAP BARS 600.

 

 

 

 

 

 

 

 

 

 

V bars 2000
y os
4 6 @ 400 crg > Taig
2000 | 1400 N20 600
1800 | 1300 Nlé 600 q
1400 | 1000 Nlé 500
1200 | 800 NI2 500
F72 FABRIC. 7
Se
1) 1
4

 

Nlé LOGITUDINAL BARS
@400 CRS. LAP 500

WHERE REQUIRED AND
AT CORNERS.

 

 

B

S
wo
N
a

No, @400 CRS

RW3 DETAILS

 

R:\rienmacfiles\Rienmac\15\Large\15330 - Lt 219 Corsair Cr, Sunrise Bch - Steve-Dianne Selby - Des Crawford\15330.dwg, Model,
26/11/2015 9:22:17 AM, L Roth, Rienmac Pty Ltd, CutePDF Writer, A3, 1:100

1200 MAX

NI2 VER BARS @400

 

CRS CENTRALLY IN
WALL. LAP 500 WITH
STARTERS # 400 WITH
SLAB MESH.

NI2 HORIZONTAL BARS @400

CRS. LAP 500 WHERE
REQUIRED € AT CORNERS.

NI2 STARTERS @400 ~~ TJ

CRS,

PROVIDE GRANULAR BACKFILL ¢ AGG DRAIN
.~ WRAPPED IN GEOFABRIC SOCK, CONNECTED

 

 

 

 

 

 

 

 

 

 

4
TO SW LINE BEHIND ALL RETAINING WALLS,
SLOPE DRAIN | IN 00.
100 SLAB ON GROUND.
F82 MESH 30 TOP COVER,
NI2 VER BARS @400 = —\
CRS CENTRALLY IN a
WALL. LAP 500 WITH (ISSA
/
ors ipoa 400 WITH L / 190 CONCRETE FILLED
x : ye BLOCKWALL.
= 4, GROUT = 20MPa
| NI2 HORIZONTAL BARS @400 JXé SLUMP = 225mm
3] CRS. LAP 500 WHERE KR MAX AGG SIZE = 5mm
REQUIRED # AT CORNERS, JK PROVIDE CONTROL JOINTS
/ @6m CRS MAX.
LL /
NI2 STARTERS @400 ~~ J | APPROVED WATERPROOF
CRS. | O/ MEMBRANE.
ope Ys 4 BAR FIITM TOP ¢ BOTTOM.

 

  

USE FOR FB4 ALSO
IF REQUIRED,

 

 

| RIo TIES @600 CRS.
S 50 COVER.

PROP WALL UNTIL
SLAB OVER IS CAST.

 

 

 

 

 

 

 

 

 

PROVIDE GRANULAR BACKFILL @ AGG DRAIN
WRAPPED IN GEOFABRIC SOCK, CONNECTED
TO SW LINE BEHIND ALL RETAINING WALLS.
SLOPE DRAIN | IN 100.

   
 

——Y 4

 

BLOCKWALL.
GROUT = 20MPa
SLUMP = 225mm

PROVIDE CONTROL
@6m CRS MAX,

MEMBRANE,

 

 

 

 

600 MIN

RWI

 
   

 

 

 

 

 

 

 

 

 

 

 

 

PETER RIENECKER - RPEQ 2088

ERE

190 CONCRETE FILLED
MAX AGG SIZE = 5mm

APPROVED WATERPROOF

| __4 BAR FIITM TOP ¢ BOTTOM.

100 SLAB ON GROUND.
| LAYER F72 MESH 30 TOP

RIENMAC ery ito

ABN. 52 010 666 430 AC.N. 010 666 430
CONSULTING CIVIL &
STRUCTURAL ENGINEERS

SUNSHINE COAST OFFICE:
SUITE 5, FIRST FLOOR,
SAINT CIRINO, F
[37 BRISBANE ROAD,

(PO BOx 144)
MOOLOOLABA @LD 4557

RETAINING

| LAYER

P:- (07) 5478 250d
(07) 5444 |I5q
Email:- info@rienmac. biz

[email protected]!
Web:- www.rienmac. bi:

 

CLIENT:
CONNETIVITY PTY LTD
PROJECT:

PROPOSED UNITS
JOINTS

LOT 219 CORSAIR CRESENT
SUNRISE BEACH @LD 4567

REAL PROPERTY DESCRIPTION # COUNCIL:
LOT 219, RP 135364

PARISH OF WEYBA, COUNTY OF MARCH
SUNSHINE COAST REGIONAL COUNCIL

 

 

 

 

 

 

 

 

rT | RIO TIES @600 CRS, DETAILS
S 50 COVER,
Wa)
PROP WALL UNTIL -
L_ Designed: PLR = Drawn: LR
SLAB OVER IS CAST.
—=— SCALES: 1:20
Engineer: PLR |DATE: 25 MAY [5
permnision fram Rlenmae Coaultng Engreers “| JOB NUMBER DWG No. | ISSUE
| DO NOT SCALE OFF DRAWINGS, | A3 |SHEET '2 OF 2| |CHECKED: PLR

 

 

 

 

Page 13

 

BS

 

 

 

 

|
|
te ANGLE PLATE.
2/Mlé CHEMICAL ANCHORS TO

 

BS TO

BLOCKWALL. 2/M20 TO B8.

BLOCKWALL

WALL FRAMING AS DETAILED.

 

B7

 

i JOIST HANGER J3 TO B7.
\ |

J3 >

 

 

MI2 HD BOLT LAP 500 WITH _/
BLOCK WALL REINFORCEMENT.

 

BP2

| — 2/NI6 VERTICAL BARS.

LAP 700 WITH 2/NIé FROM FOOTING.

 

00. MIN.

 

3,

 

 

 

 

 

 

300

PI

 

 

PFI DETAILS

R:\rienmacfiles\Rienmac\15\Large\15330 - Lt 219 Corsair Cr, Sunrise Bch - Steve-Dianne Selby - Des Crawford\15330.dwg, Model,

26/11/2015 9:22:31 AM, L Roth, Rienmac Pty Ltd, CutePDF Writer, A3, 1:100

BLOCKWALL.

N

Vv

6mm CLEAT PLATE TO B3,
2/Ml2 TO J2.

 

 

 

 

 

 

 

P

cl

\ lorem END PLATE TO Cl.
2/Mlo TO B3.

 

lOmm BASE PLATE TO Cl,

2/M|I2 HD BOLTS TO BLOCK WALL.

 

LAP 500 WITH BLOCKWALL
REINFORCEMENT.

 

 

 

 

B3 DETAILS

lOmm ANGLE.

2/Mlé CHEMICAL ANCHORS _/S
CENTRAL TO BLOCK PIER.

2/M20 TO B. FIX TO BLOCK
WALL SIMILARLY.

lomm ‘Ll! PLATE.
pl, LY es CHEMICAL ANCHORS
a | TO BLOCKWALL.

B3 HO B3 ® 2/Ml6 TO B3.

Bq

BPI

!Omm ANGLE.

2/M|2 CHEMICAL ANCHORS
TO BLOCKWALL.

2/Mlé TO RBI.

 

 

 

 

 

 

 

 

 

 

lOmm ANGLE. 2/Ml2 TO Bé.

2/MI2 CHEMICAL ANCHORS TO BLOCK PIER,
B5 SIMILAR 2/Mlé TO B5.

2/MI2 CHEMICAL ANCHORS CENTRAL TO
BLOCK PIER.

 

~<|o
| |

J4

 

 

UNE
| ka

t

KY

at

3/NI6 VERTICAL BARS. LAP 700 WITH

[—_ STARTERS FROM FOOTING AND AT FIRST

FLOOR LEVEL.

 

 

 

 

  

 

 

a PF2

lOmm ANGLE.
2/Mlé TO RB3.
2/MI6 @ RBI.

\ _— | Y RB2 =

ere

4 \ lOmm ANGLE
\ Imm LE.
~~ RB3 2/Ml6 TO RB2.

2/Mlé TO RB3.
TRUSS
A=

RIENMAC ery ito

ABN. 52 010 666 430 AC.N. 010 666 430
CONSULTING CIVIL &
STRUCTURAL ENGINEERS

SUNSHINE COAST OFFICE:
SUITE 5, FIRST FLOOR,
SAINT CIRINO, F
[37 BRISBANE ROAD,

(PO BOx 144)
MOOLOOLABA @LD 4557

P:- (07) 5478 250d
(07) 5444 |I5q
Email:- info@rienmac. biz

[email protected]!
Web:- www.rienmac. bi:

 

CLIENT:
CONNETIVITY PTY LTD
PROJECT:

PROPOSED UNITS

LOT 219 CORSAIR CRESENT
SUNRISE BEACH @LD 4567

REAL PROPERTY DESCRIPTION # COUNCIL:
LOT 219, RP 135364

PARISH OF WEYBA, COUNTY OF MARCH
SUNSHINE COAST REGIONAL COUNCIL
DRAWING TITLE:

NI2 'U! BARS @I50CRS EACH WAY
~~ BOTTOM REINFORCEMENT 65 COVER.

 

 

 

 

PF2 DETAILS

 

 

 

PETER RIENECKER - RPEQ 2088

 

 

 

 

 

 

 

 

 

 

DETAILS
NI2 'U' BARS @I50 CRS EACH WAY
[BOTTOM REINFORCEMENT 65 COVER.
Designed: PLR Drawn: LR
SCALES: 1:20
Engineer: PLR |DATE: 25 MAY |5
pamsion Hom Riemnec Coiling Engreers [JOB NUMBER DWG No. | ISSUE
DO NOT SCALE OFF DRAWINGS, | A3 |SHEET 13 OF 21 |CHECKED: — PLR

 

 

Page 14

100 SLAB ON GROUND.
| LAYER F72 MESH 30 TOP COVER
CRANK MESH CENTRALLY INTO SLAB.

    
 

STAIR ON NATURAL GROUND OR
COMPACTED FILL.

 

 

SMA

3 BAR FIITM 50
BOTTOM COVER.

STAIR ON GROUND

1

 
  
    

3 BAR FIITM 50 BOTTOM COVER.
NI2 TIES @400mm CRS.
LAP 500 WITH SLAB MESH.

DETAILS

TRUSSES
\

140x45 MGPI2 PLATE MI2 HD
BOLTS AT ENDS & 1200mm CRS
MAX STAGGER EITHER SIDE OF

 

FLOOR # WALL FRAMING AS

. WALL. A
’ WALL FRAMING AS ¥
Jo DETAILED.
| PP3 PP3
7 ti y Jf ify EA
. 1 1 Wy Hh

 

 

 

 

90x45 MGPI2 WALL PLATE, MI2

DETAILED,
4 CK
. d
L 90x45 MGPI2 WALL PLATE. MI2 S|

HD BOLTS AT ENDS AND @1200
CRS MAX.

 

HD BOLTS AT ENDS AND @1200
CRS MAX.

TYPICAL TO TOP OF ALL BLOCK
WALLS UNO.

NI2 HOR BARS @400 CRS.
LAP 450 WHERE REQ'D AND
| AT CORNERS.

NI2 VER BARS @400 ly

 

NI2 VER BARS @400

\ FOOTING.
RIO TIES @600 CRS, BENT

 

CRS, LAP 500 WITH
STARTERS FROM
FOOTING.

INTO SLAB. LAP 400 WITH
FABRIC, MAINTAIN 30 TOP
COVER WITH FABRIC.

CRS. LAP 600 WITH —_|
STARTERS FROM V4

Bl

 

 

F82 FABRIC TOP

 

 

  
 
 

50 SAND BED.

 

 

 

 

oS

 
  

 

 

50 SAND BED.

fo WATERPROOF MEMBRANE
- TYPICAL.

 

 

 

EDG

[450 | | 4 BAR FIITM.

EDGE

50 BTM COVER,
50 MIN

E BEAM FB3

R:\rienmacfiles\Rienmac\15\Large\15330 - Lt 219 Corsair Cr, Sunrise Bch - Steve-Dianne Selby - Des Crawford\15330.dwg, Model,

26/11/2015 9:23:39 AM, L Roth, Rienmac Pty Ltd, CutePDF Writer, A3, 1:100

450

 
  

 

WATERPROOF MEMBRANE
- TYPICAL,

4 BAR FIITM.
50 BTM COVER.
50 MIN

BEAM FBI

 

 

 

PETER RIENECKER - RPEQ 2088

 

 

NI2 HOR BARS @400 CRS, {Cl
/—~ LAP 450 WHERE REQ'D AND
\ J AT CORNERS. Lt
RIO TIES @600 CRS, BENT
INTO SLAB, LAP 400 WITH Pim END PLATE
FABRIC. MAINTAIN 30 TOP
F72 FABRIC TOP 2mi2 TO Bl,
COVER WITH FABRIC, 30 COVER, lOmm BASE PLATE
To Cl.
\ 5.0.G 2/12 HD BOLTS
v tL |S TO FOOTING,

RIENMAC ery ito

ABN. 52 010 666 430 AC.N. 010 666 430
CONSULTING CIVIL &

STRUCTURAL ENGINEERS

SUNSHINE COAST OFFICE:
SUITE 5, FIRST FLOOR, P:- (07) 5478 250d
SAINT CIRINO, F:- (07) 5444 {158
137 BRISBANE ROAD, Email:-info@rienmac. biz
(PO BOX 149) info@rienmac,ne'
MOOLOOLABA QLD 4557 Web:- www ,rienmac.bi

 

CLIENT:
CONNETIVITY PTY LTD
PROJECT:

PROPOSED UNITS

LOT 219 CORSAIR CRESENT
SUNRISE BEACH @LD 4567

REAL PROPERTY DESCRIPTION # COUNCIL:
LOT 219, RP 135364

PARISH OF WEYBA, COUNTY OF MARCH
SUNSHINE COAST REGIONAL COUNCIL
DRAWING TITLE:

 

 

 

 

 

 

DETAILS

Designed: PLR Drawn: LR

SCALES: 1:20

Engineer: PLR |DATE: 25 MAY |5
pamsion Hom Riemnec Coiling Engreers [JOB NUMBER DWG No. |_ISSUE
DO NOT SCALE OFF DRAWINGS, | A3 |SHEET 14 OF 21 |CHECKED: — PLR

 

 

 

 

Page 15

 

 

 

 

 

 

 

 

 

 

 

SLAB REINFORCING
AS DETAILED.
43 =
S or
3 SS hI 2
N 3 ; = = Ss
°
TYPICAL BLOCKWALL WITH REINFORCEMENT WATERPROOF
WHERE NOT RETAINING. MEMBRANE
NI2 VER BARS @400mm CRS CENTRAL IN WALL. eA ,
LAP 500 WITH STARTERS FROM FOOTING # 300 1241
WITH SLAB REINFORCEMENT OVER IF PRESENT. Ty PROVIDE GRANULAR BACKFILL ¢ AGG DRAIN WRAPPED

NI2 HOR BARS @400mm CRS. LAP 450 WHERE |

IN GEOFABRIC SOCK, CONNECTED TO SW LINE BEHIND
REQUIRED AND AT CORNERS.

ALL RETAINING WALLS. SLOPE DRAIN | IN 100.

3m MAX
|
|

55
125 SLAB ON GROUND. COVER

D
| LAYER F82 MESH 40 TOP P| | Nlé VER BARS @200mm CRS.
COVER. tH [ LAP 700 WITH STARTERS FROM FOOTINGé 300
WITH SLAB TOP REINFORCING.

NI2 HOR BARS @400mm CRS. RI ENMAC PTY LTD

 

 

100 SLAB ON GROUND,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

| LAYER F82 MESH 30 TOP COVER. I |
LZ} +} LAP 450 WHERE REQUIRED AND AT CORNERS. ABN. 52 010 666 430 A.C.N. 010 666 430
Yoh / CONSULTING CIVIL &
E 2h oO] STRUCTURAL ENGINEERS
< L \ |
I — SUNSHINE COAST OFFICE:

VADRERXSRERE oe | 3 PROP WALL UNTIL SUITE 5, FIRST FLOOR, P:- (07) 5478 250d
~ s | & SLAB OVER |S CAST. SAINT CIRINO, F:- (07) 5444 {I6d
B Fe ' OPPO ™”YS | 137 BRISBANE ROAD, Email:- info@rienmac. biz
50mm SAND BED ¢ “ 7 |Z (PO BOX 149) [email protected]
WATERPROOF MEMBRANE. EBA L__ 8 RW2 | = TOOLOO. ABA QLD 4557 Web:- www, rienmazc.bi.

0 4 BAR FIITM 50 BOTTOM COVER. [| o ~3 ~a a7 a 8 CONNETIVITY PTY LTD

45 . Qo._9o © oO ~o
[._450__| RIO TIES TO SLAB @600 CRS, ————_

 

 

 

750 J PROJECT:

= PROPOSED UNITS
UNDER RW2 AS NECESSARY FOR BLOCK
PIER UNDER UPPER FOOTING BEAMS.

RW? D ET AI LS LAP 4 BAR FIITM INTO THICKENING, LOT 219 CORSAIR CRESENT
SUNRISE BEACH @LD 4567

REAL PROPERTY DESCRIPTION # COUNCIL:
LOT 219, RP 135364

PARISH OF WEYBA, COUNTY OF MARCH
SUNSHINE COAST REGIONAL COUNCIL
DRAWING TITLE:

 

 

 

DETAILS
Designed: PLR Drawn: LR
SCALES: 1:20

 

Engineer: PLR |DATE: 25 MAY I5

5330 §=6SI5|) A

passant Riowmee Corsling Engraers "| JOB NUMBER DWG No, | ISSUE
PETER RIENECKER - RPEQ 2088 | | Do NoT SCALE oFF DRAWINGS, | A3 |SHEET |5 OF 21 |CHECKED: PLR

 

 

 

 

 

 

 

 

 

 

R:\rienmacfiles\Rienmac\15\Large\15330 - Lt 219 Corsair Cr, Sunrise Bch - Steve-Dianne Selby - Des Crawford\15330.dwg, Model,
26/11/2015 9:23:51 AM, L Roth, Rienmac Pty Ltd, CutePDF Writer, A3, 1:100

 

Page 16

THICKNES

 

“

 

 

WATER LEVEL ——} rw
a 2
> “
TT Pd 8
TT ——1/S|2 EXTRA TYPICAL. -
350 MAX ° 16
REFER PLAN =
WATERPROOF <
HEIGHT H_ | THICKNESS T LS CEMENT RENDER, pL
COPING BEAM 1000 - |500 200 a7 REINFORCEMENT
1500 - 2000 250 ' AS DETAILED
AS DETAILED. 150 PLACED CENTRALLY.

 

350 MAX 4/512

300 MAX 3/512

350 MAX

 

fp

275 MIN
REFER PLAN

WATER LEVEL}

 

75

 

 

 

 

 

 

 

 

 

 

WATER LEVEL

 

 

 

 

 

 

ws

F42 MESH
25 COVER TO
OUTSIDE FACE

 

HEIGHT H

500 LAP
Sl2 AT 300 |

 

 

 

 

 

 

600 MIN

 

200
MIN

 

 

2/5|2 —>r

 

 
 

   

REINFORCEMENT AS
DETAILED 50 COVER
TO WATER FACE

REMAINING DETAILS
AS BEFORE.

 

 

 

 

 

 

 

 

 

 

REINFORCEMENT AS
I=— DETAILED 50 COVER
TO WATER FACE.

REMAINING DETAILS
AS PER ABOVE.

 

 

 

 

 

 

 

 

 

IN GROUND DETAIL

 

 

 

OUT OF GROUND DETAIL

 

COPING BEAM TYPE A

POOL CONSTRUCTION SPECIFICATION

|. WORKMANSHIP € MATERIALS TO BE IN ACCORDANCE WITH AS2783 CONCRETE SWIMMING POOL
CODE AND LOCAL AUTHORITY'S REQUIREMENTS.

2. POOL FILLING € SOIL BACKFILLING NOT TO BE CARRIED OUT UNTIL WALLS ¢ FLOOR HAVE
REACHED DESIGN STRENGTH.

3. 50mm LAYER OF 22mm GRAVEL TO BE PLACED UNDER POOL FLOOR.

4. ALL CONCRETE TO BE PRESSURE APPLIED BY 'PRESSURECRETE' METHOD WITH AN AVERAGE
COMPRESSIVE STRENGTH OF 32MPa AT 28 DAYS.

RIENMAC ery ito

ABN. 52 010 666 430 AC.N. 010 666 430
CONSULTING CIVIL &
STRUCTURAL ENGINEERS

SUNSHINE COAST OFFICE:

ALL CONCRETE ON PLAN TO BE 300mm RADIUS UNLESS NOTED OTHERWISE.

ALL REINFORCEMENT TO BE HOT ROLLED DEFORMED BARS 'S' é 'Y',

SUITE 5, FIRST FLOOR,
SAINT CIRINO,

[37 BRISBANE ROAD,

(PO BOx 144)
MOOLOOLABA @LD 4557

P:- (07) 5478 250d
F:- (07) 5444 lI58
Email:- info@rienmac. biz
[email protected]!

Web:- www.rienmac. bi:

 

 

 

400

 

 

000
000 |

 

a
SS

 

 

THICKNE

POOL FOOTING DETAIL FOR
FLOOR <G00_IN GROUND

 

R:\rienmacfiles\Rienmac\15\Large\15330 - Lt 219 Corsair Cr, Sunrise Bch - Steve-Dianne Selby - Des Crawford\15330.dwg, Model,

26/11/2015 9:24:05 AM, L Roth, Rienmac Pty Ltd, CutePDF Writer, A3, 1:100

7. CROSS RODS NOT NOTED TO BE SI2 @ 300 CRS.

8. ALL BARS TO HAVE A SPLICE LENGTH OF 600mm, UNO.

9. MAIN REINFORCEMENT TO HAVE 65mm COVER TO GROUND FACE. WHERE A SECOND LAYER OF
REINFORCEMENT IS USED COVER IS TO BE 40mm TO WATER FACE, COVER TO TOP STEEL OF
COPING TO 25mm FROM TOP OF CONCRETE. COVER TO BOTTOM STEEL IN COPING IS TO BE
40mm FROM BOTTOM OF CONCRETE.

10. SPLICES IN ADJACENT REINFORCEMENT BARS TO BE STAGGERED.

ll, DEEP END TO HAVE AT LEAST 0.3m OF FIRM, NATURAL SOIL OR EQUIVALENT RETAINING WALL,
ETC AS SUPPORT.

12. SUPPORTING SOIL TO BE SOUND NATURAL SOIL OR WELL COMPACTED FILLING WITH BEARING
CAPACITY AT ANY DEPTH NOT LESS THAN l00kPa.

13. DESIGN TO BE MODIFIED IF EXCESS GROUND WATER IS ENCOUNTERED DURING EXCAVATION.
14. ALL DIMENSIONS ON SITE PLAN SHOWING THE POSITION OF THE POOL ARE TO THE WATER FACE.

I5. POOL OWNER TO BE INFORMED THAT AN ELEMENT OF RISK TO THE POOL STRUCTURE IS
INVOLVED IF THE POOL IS EMPTIED.

 

CLIENT:
CONNETIVITY PTY LTD
PROJECT:

PROPOSED UNITS

LOT 219 CORSAIR CRESENT
SUNRISE BEACH @LD 4567

REAL PROPERTY DESCRIPTION # COUNCIL:
LOT 219, RP 135364

PARISH OF WEYBA, COUNTY OF MARCH
SUNSHINE COAST REGIONAL COUNCIL
DRAWING TITLE:

 

 

 

 

 

 

PETER RIENECKER - RPEQ 2088

 

 

 

DETAILS

Designed: PLR Drawn: LR

SCALES: 1:20

Engineer: PLR |DATE: 25 MAY [5
pamsion Hom Riemnec Coiling Engreers [JOB NUMBER DWG No. |_ISSUE
DO NOT SCALE OFF DRAWINGS, | A3 |SHEET le OF 21 |CHECKED: — PLR

 

 

 

 

Page 17

WATER LEVEL

   

SI2 BARS @300 CRS
EACH WAY.

 

 

 

 

 

 

STEP DETAIL
INDICATIVE ONLY,

PROVIDE 2/512 HORIZ |200Ig

TOP AND BIM AT SKIMMER

SEFER é SIMILAR OPENINGS
PLAN sayy ye - Saep DE 5
MAXIUM POOL LENGTH FOR STANDARD DETAILS = 12r

SKIMMER

 

PUMP

 

 

DISCHARGE TO COUNCIL
REQUIREMENTS.

 

MAIN DRAIN

 
 

150_,; 2000 , |50

 

 

 

 

 

 

TO POOL INLETS

DIAGRAMMATIC WATER RETICULATION

 

 

 

 

 

 

fo

300 DEEP
RUBBER PIT.

ve

 

 

 

 

500_S@

 

 

 

1
ban DRAIN LINE

2/312 BARS EACH
SIDE EACH WAY,

HYDROSTATIC VALVE

MAIN DRAIN DETAIL
TO BE INSTALLED AT LOWEST

POINT OF

BOx

REFER PLAN FOR WIDTH

 

FOR POOL LENGTH > 12m HORIZONTAL REINFORCEMENT 10
BE S12 AT 200 MAX CRS (MAXIMUM LENGTH = I7m)

 

 

F.S.L.

 

   

 

 

 
 

 

 

 

Leica COPING

 

BEAM TYPE B

 

 

 

   
 
  

 

F.Sb. ff
TYPICAL COPING BFA Jes | EI,
TYPE A a|%
512 AT 300
EXTRA A
REQUIRED.

&
oO

FOR D > 1200 PROVIDE EXTRA

S12 VERTICAL BARS AT 300 MAX CRS
1000 (D = 1500 MAX)

TYPICAL LONGITUDINAL SECTION
SCALE 1:50

R:\rienmacfiles\Rienmac\15\Large\15330 - Lt 219 Corsair Cr, Sunrise Bch - Steve-Dianne Selby - Des Crawford\15330.dwg, Model,
26/11/2015 9:24:18 AM, L Roth, Rienmac Pty Ltd, CutePDF Writer, A3, 1:100

HYDROSTATIC VALVE TO BE
INSTALLED AT LOWEST POINT

   

[ SI2 BARS AT 300 MAX CRS

EACH WAY UNO

POOL.

 

 

PETER RIENECKER - RPEQ 2088

RIENMAC ery ito

ABN. 52 010 666 430 AC.N. 010 666 430
CONSULTING CIVIL &
STRUCTURAL ENGINEERS

SUNSHINE COAST OFFICE:
SUITE 5, FIRST FLOOR,
SAINT CIRINO,

[37 BRISBANE ROAD,

(PO BOx 144)
MOOLOOLABA @LD 4557

P:- (07) 5478 250d
F:- (07) 5444 lI58
Email:- info@rienmac. biz
[email protected]!

Web:- www.rienmac. bi:

 

CLIENT:
CONNETIVITY PTY LTD
PROJECT:

PROPOSED UNITS

LOT 219 CORSAIR CRESENT
SUNRISE BEACH @LD 4567

REAL PROPERTY DESCRIPTION # COUNCIL:
LOT 219, RP 135364

PARISH OF WEYBA, COUNTY OF MARCH
SUNSHINE COAST REGIONAL COUNCIL
DRAWING TITLE:

 

 

 

 

 

 

 

 

DETAILS

Designed: PLR Drawn: LR

SCALES: 1:50, 1:20

Engineer: PLR |DATE: 25 MAY I5
parmissin fram Riownee Corsling tngraers | SOB NUMBER DWG No. | ISSUE
DO NOT SCALE OFF DRAWINGS. | A3 |SHEET !7 OF 21 |CHECKED: PLR

 

 

 

 

Page 18

GENERAL NOTES

e THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITH ALL ARCHITECTURAL AND OTHER
CONSULTANTS DRAWINGS AND SPECIFICATIONS AND WITH SUCH OTHER WRITTEN INSTRUCTIONS AS
MAY BE ISSUED DURING THE COURSE OF THE CONTRACT. ALL DISCREPANCIES SHALL BE
REFERRED TO THE SUPERINTENDENT FOR DECISION BEFORE PROCEEDING WITH THE WORK.

e ALL DIMENSIONS RELEVANT TO SETTING OUT AND OFF-SITE WORK SHALL BE VERIFIED BY THE
CONTRACTOR BEFORE CONSTRUCTION AND FABRICATION IS COMMENCED, THE ENGINEER'S
DRAWINGS SHALL NOT BE SCALED.

« DURING CONSTRUCTION THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING THE
STRUCTURE IN A STABLE CONDITION AND ENSURE NO PART IS OVER-STRESSED.

« WHERE EXCAVATION WORK IS TO BE CARRIED OUT ADJACENT TO EXISTING FOOTINGS, THE EXACT
LEVEL OF THE UNDERSIDE OF THE FOOTINGS SHALL BE OBTAINED BY TEST PITS PRIOR TO
EXCAVATION. UNDERPINNING AND SHORING OF THE STRUCTURE SHALL BE CARRIED OUT AS
REQUIRED AND THE EXISTING STRUCTURE SHALL BE MAINTAINED IN A STABLE AND UNDAMAGED
CONDITION,

« WORKMANSHIP AND MATERIALS SHALL BE IN ACCORDANCE WITH THE RELEVANT CURRENT SAA
CODES (INCLUDING ALL AMENDMENTS) AND THE STATUTORY AUTHORITIES REQUIREMENTS,
EXCEPT WHERE VARIED BY THE CONTRACT DOCUMENTS.

e ALL DIMENSIONS ARE IN MILLIMETRES, UNLESS NOTES OTHERWISE, ALL LEVELS ARE EXPRESSED
IN METRES.

FOOTING NOTES
e ALL FOOTING EXCAVATIONS SHALL BE CLEANED OF LOOSE MATERIALS AND WATER,

e WHERE VERIFIED FOUNDATION MATERIAL IS BELOW THE UNDERSIDE OF FOOTINGS AS DETAILED,
BACKFILL ADDITIONAL EXCAVATION WITH WEAK MIX CONCRETE.

« SIDES OF FOOTINGS SHALL BE FORMED AS NECESSARY WHEN EXCAVATED FACE |S NOT STABLE.

e¢ ALL WALLS AND COLUMNS SHALL BE CONCENTRIC WITH SUPPORTING FOOTINGS, UNLESS
OTHERWISE NOTED ON THE DRAWINGS,

e UNLESS APPROVED BY THE SUPERINTENDENT, EXCAVATIONS SHALL NOT EXTEND BELOW A LINE
DIPPING AT 30° AND AWAY FROM THE NEAREST UNDERSIDE CORNER OF ANY FOOTINGS.

BLOCKWORK NOTES

¢ BLOCKWORK SHALL NOT BE FILLED TO A HEIGHT OF GREATER THAN 2400mm, DURING ANY ONE
POUR.

* CONCRETE BLOCKS TO HAVE A CHARACTERISTIC STRENGTH OF IS5MPa MINIMUM.
¢ BUILD ALL FIXINGS FOR ARCHITECTURAL DETAILS,

* ALL BLOCKWORK MATERIALS AND WORKMANSHIP SHALL COMPLY WITH AS3700. BLOCKS FOR USE
IN REINFORCED CONCRETE FILLED WALLS SHALL BE 20.48 ¢ 15.48 SERIES.

* MORTAR SHALL BE MIXED BY MECHANICAL MIXERS IN ACCORDANCE WITH ASI23 IN THE FOLLOWING
PROPORTIONS BY VOLUME OF- PORTLAND CEMENT : HYDRATED LIME : CLEAN PIT SAND,
- BELOW DAMP COURSE LEVEL | : 0.25 : 3
- ABOVE DAMP COURSE LEVEL | : |: 6
ALL BLOCKS SHALL BE LAID ON A FULL BED OF MORTAR.

e ALL WALLS SHALL BE BONDED OR TIED AT THEIR INTERSECTIONS,

* REINFORCED CONCRETE MASONRY WALLS SHALL BE FILLED WITH GROUT OF F'c = 20MPa; SLUMP =
225mm; MAXIMUM AGGREGATE SIZE = 5mm; CLEAN OUT BLOCKS SHALL BE EMPLOYED IN THE
BOTTOM COURSE AND ALL MORTAR DROPPINGS RAKED OUT PRIOR TO FILLING.

¢ GROUT FILLING SHALL BE THOROUGHLY RODDED USING A PLAIN ROUND BAR,

TIMBER NOTES

e ALL TIMBER ELEMENTS AND CONSTRUCTION DETAIL ARE TO COMPLY WITH THE DETAILS GIVEN IN
AS51684 NATIONAL TIMBER FRAMING CODE WIND CLASSIFICATION N3.

« ALL TRUSSES TO BE DESIGNED BY THE MANUFACTURER TO THE WIND LOAD SPECIFIED, THE
TRUSS MANUFACTURER IS TO SPECIFY THE TIEDOWN TO TOP PLATE APPROPRIATE TO THE
SPECIFIED DESIGN WIND VELOCITY.

e ALL TIE DOWN DETAILS TO BE SUBMITTED TO THE SUPERINTENDENT FOR VERIFICATION.

R:\rienmacfiles\Rienmac\15\Large\15330 - Lt 219 Corsair Cr, Sunrise Bch - Steve-Dianne Selby - Des Crawford\15330.dwg, Model,
26/11/2015 9:25:07 AM, L Roth, Rienmac Pty Ltd, CutePDF Writer, A3, 1:100

STRUCTURAL STEELWORK NOTES

« ALL WORKMANSHIP AND MATERIALS SHALL BE IN ACCORDANCE WITH AS4I00, AS/NZS4600,
AS/NZS1554 AND AS/NZSHB62.

« UNLESS NOTED OTHERWISE, ALL STEEL SHALL BE:
- GRADE 300 PLUS FOR HOT ROLLED SECTIONS,
- GRADE 300 PLUS FOR WELDED SECTIONS (WB, WC).
- GRADE 300 PLUS FOR MERCHANT BAR (ROUND, SQUARE AND FLAT).
- GRADE 250 FOR PLATES,
- GRADE C350 FOR RHS, SHS AND CHS,

* COMMERCIAL GRADE BOLTS SHALL CONFORM TO AS/NZSIII! AND AS4I00, HIGH STRENGTH
STRUCTURAL BOLTS SHALL CONFORM TO AS/NZSI252 AND AS4I00. WELDS SHALL CONFORM TO
AS/NZSI554 AND WELDING ELECTRODES TO AS/NZSI553,

« ALL DETAILS, GAUGE LINES, ETC, WHERE NOT SPECIFICALLY SHOWN ARE TO BE IN ACCORDANCE
WITH AISC DESIGN CAPACITY TABLES FOR STRUCTURAL STEEL AND AISC STANDARDISED
STRUCTURAL CONNECTIONS.

¢ BEFORE FABRICATION IS COMMENCED THE CONTRACTOR SHALL SUBMIT COPIES OF THE SHOP
DRAWINGS TO RIENMAC FOR REVIEW. REVIEW DOES NOT INCLUDE CHECKING OF DIMENSIONS,

e UNLESS NOTED OTHERWISE, ALL WELDS SHALL BE 6mm CONTINUOUS FILLET FROM E48XX
ELECTRODES. ALL WELDS SHALL BE CATEGORY SP.

e ALL BOLTS SHALL BE GRADE 8.8/5 UNLESS NOTED OTHERNISE.
ALL BOLTS SHALL BE M20, UNLESS NOTED OTHERNISE,

* ALL CLEATS AND GUSSETS SHALL BE l0mm PLATE, UNLESS NOTED OTHERWISE.

« CONCRETE ENCASED STEELWORK SHALL HAVE A MINIMUM OF 50mm OF CONCRETE ENCASEMENT
REINFORCED WITH W5 WIRE WRAPPING AT [50 CRS OR FGW4l FABRIC, UNLESS NOTED OTHERNISE.

¢ STRUCTURAL STEELWORK SHALL HAVE THE FOLLOWING SURFACE TREATMENT IN ACCORDANCE
WITH AS/NZS23I2, UNLESS NOTED OTHERWISE,

ELEMENT SURFACE CLEANING PRIME COAT TOP COATS

ALL STEELWORK 75 MICRONS REFER ARCHITECT

WITHIN AIRSEAL CLASS | ZINCPHOSPHATE

OF BUILDING

ALL STEELWORK HOT DIP REFER ARCHITECT
OUTSIDE AIRSEAL CLASS 2.5 GALVANISED

OF BUILDING

*« MEMBERS TO BE ENCASED IN CONCRETE OR FIRE SPRAYED MUST NOT BE PAINTED,

« ALL HOT DIP GALVANISED MEMBERS SHALL BE PROVIDED WITH VENT AND DRAINAGE HOLES IN
ACCORDANCE WITH THE GALVANISER'S RECOMMENDATIONS,

¢ WHERE MEMBERS SHOWN ON THE STRUCTURAL OR ARCHITECTURAL DRAWINGS ARE REQUIRED TO
BE CURVED, BENT OR ROLLED, THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE METHODS.
REQUIRED TO ACHIEVE THE REQUIRED SHAPES WITHOUT LOCALISED DISTORTION OF THE MEMBERS.
¢ TRIMMING MEMBERS FOR MECHANICAL/HYDRAULIC PENETRATIONS ARE NOT NECESSARILY SHOWN.

¢ TRIMMING MEMBERS FOR VALLEYS, FREE EDGES, RIDGES, ETC ARE NOT NECESSARILY SHOWN,
REFER TO PURLIN MANUFACTURER'S FOR DETAILS.

¢  F.S.B.W. INDICATES COMPLETE PENETRATION FULL STRENGTH BUTT WELD.

¢ THE CONTRACTOR SHALL PROVIDE AND LEAVE IN PLACE UNTIL PERMANENT BRACING ELEMENTS
ARE CONSTRUCTED, SUCH TEMPORARY BRACING AS IS NECESSARY TO STABILISE THE STRUCTURE
DURING ERECTION.

* ROOF AND/OR WALL SHEETING SHALL BE FIXED TO PURLINS OR GIRTS IN ACCORDANCE WITH
MANUFACTURER'S SPECIFICATIONS.

¢ CAP HOLLOW SECTIONS WITH 3mm END PLATES, UNO.

* FOR GALVANISED COATINGS, REPAIR DAMAGE AND SITE WELDS WITH TWO COATS OF TWO PACK
EPOXY POLYAMIDE ZINC-RICH PAINT CONTAINING A MINIMUM 92% ZINC DUST IN THE DRY FILM,

*« GROUT UNDER BASEPLATES TO BE HIGH STRENGTH CEMENTITIOUS, NON-SHRINK MASTERFLOW 870
or EQUIVALENT, UNO.

 

RIENMAC ery ito

ABN. 52 010 666 430 AC.N. 010 666 430
CONSULTING CIVIL &
STRUCTURAL ENGINEERS

SUNSHINE COAST OFFICE:
SUITE 5, FIRST FLOOR,
SAINT CIRINO, F
[37 BRISBANE ROAD, Email
(PO BOx 144)
MOOLOOLABA @LD 4557

 

P:- (07) 5478 250d
(07) 5444 |I5q
[email protected]
[email protected]!
Web:- www.rienmac. bi:

 

CLIENT:
CONNETIVITY PTY LTD
PROJECT:

PROPOSED UNITS

LOT 219 CORSAIR CRESENT
SUNRISE BEACH @LD 4567

REAL PROPERTY DESCRIPTION # COUNCIL:
LOT 219, RP 135364

PARISH OF WEYBA, COUNTY OF MARCH
SUNSHINE COAST REGIONAL COUNCIL
DRAWING TITLE:

GENERAL NOTES

 

Designed: PLR Drawn:

LR

 

SCALES:

 

Engineer: PLR

DATE: 25 MAY I5

 

5330 | SIla

 

A

 

 

 

 

 

 

rine hae Band iy Cees wt | JOB NUMBER DWG No. | ISSUE
PETER RIENECKER - RPEQ@ 2088 DO NOT SCALE OFF DRAWINGS, | A3 |SHEET 18 OF 21 |CHECKED: PLR

 

 

Page 19

CONCRETE NOTES

ALL WORKMANSHIP AND MATERIALS SHALL BE IN ACCORDANCE WITH AS3600.

ALL SLABS ON GROUND TO BE CAST ON A WATERPROOF MEMBRANE ON A 50mm SAND BED.
MEMBRANE IS TO EXTEND UNDER INTEGRAL GROUND BEAMS AND |S TO BE EXTENDED A MINIMUM
OF 200mm DOWN THE FACE OF DEEP BEAMS, MEMBRANE IS TO BE POLYETHYLENE FILM 0.2mm
THICK AND IMPACT RESISTANT. LAP JOINTS 200mm AND SEAL THE LAPS WITH WATERPROOF
ADHESIVE TAPE, SEAL PENETRATIONS WITH WATERPROOF TAPE,

PROVIDE A TERMITE BARRIER IN ACCORDANCE WITH AS3660.1.
ALL CONCRETE TO BE VIBRATED.

CONCRETE QUALITY SHALL BE NORMAL CLASS, UNLESS NOTED OTHERNISE.
MAXIMUM AGGREGATE SIZE = 20mm.
SLUMP = 80mm +/- |5mm.

CONCRETE STRENGTHS FOR PARTICULAR ELEMENTS SHALL BE AS FOLLOWS, UNLESS NOTED
OTHERNISE.

 

 

ELEMENT CONCRETE STRENGTH
FOOTINGS N25

SLABS ON GROUND N25
SUSPENDED SLABS

NOT EXPOSED TO WEATHER N32
SUSPENDED SLABS

EXPOSED TO WEATHER N40
COLUMNS N40

ELEMENT FORMED-

THE CONTRACTOR IS TO NOTIFY THE SUPERINTENDENT IN WRITING OF ANY ADMIXTURES TO BE
USED IN THE CONCRETE MIX. NO ADMIXTURES TO BE USED WITHOUT APPROVAL OF THE
SUPERINTENDENT. CALCIUM CHLORIDE WILL NOT BE PERMITTED AND SHALL NOT BE USED UNDER
ANY CIRCUMSTANCES,

CONCRETE TESTING - ALL TESTING SHALL BE BY 'PROJECT ASSESSMENT' AS PER AS3600.
ALL FORMWORK TO BE DESIGNED, CONSTRUCTED AND REMOVED IN ACCORDANCE WITH AS53610.
CLASS OF FORMWORK TO BE IN ACCORDANCE WITH AS53610, TABLE 3.3.1,

UNLESS SPECIFICALLY STATED OTHERWISE, ALL EXTERNAL CORNERS OF CONCRETE SHALL BE
CHAMFERED BY THE INCLUSION OF FILLETS IN THE FORMWORK. THE FILLETS SHALL HAVE A
20mm FACE TO THE CONCRETE, FINISHED TO THE SAME STANDARD AS THE FORMWORK AND
SHALL BE MITRED AT CORNERS.

ALL EXPOSED FORMED SURFACES SHALL HAVE CLASS 2 SURFACE FINISH TO AS36I0 AND ALL
UNSEEN AREAS SHALL HAVE CLASS 4 SURFACE FINISH TO AS36I0.

DIMENSIONAL TOLERANCE OF FORMWORK FOR CLASS 2 TO BE MAXIMUM I5mm DEVIATION FROM
CORRECT POSITION, CLASS 3 - 20mm AND CLASS 4 - 25mm.

POSITIONAL TOLERANCE OF FORMWORK FOR CLASS 2 TO BE MAXIMUM 5mm DEVIATION FROM
CORRECT POSITION, CLASS 3 - 20mm AND CLASS 4 - 25mm.

MINIMUM COVER TO ALL REINFORCEMENT, UNLESS NOTED OTHERWISE SHALL BE AS FOLLOWS:-

FORMED- NOT FORMED-

NOT EXPOSED EXPOSED TO CAST AGAINST

 

TO WEATHER GROUND, WATER GROUND, ETC.
OR WEATHER
COLUMN 50 50 60
BEAM 40 40 60
FOOTINGS -- 50 60
SLAB 30 40 60
WALL 25 40 60

R:\rienmacfiles\Rienmac\15\Large\15330 - Lt 219 Corsair Cr, Sunrise Bch - Steve-Dianne Selby - Des Crawford\15330.dwg, Model,
26/11/2015 9:25:21 AM, L Roth, Rienmac Pty Ltd, CutePDF Writer, A3, 1:100

CONCRETE NOTES CONT

NO HOLES GREATER THAN 150mm, CHASES OR EMBEDMENT OF PIPES GREATER THAN 40mm
OTHER THAN THOSE SHOWN OF THE STRUCTURAL DRAWINGS SHALL BE MADE IN THE CONCRETE
SLABS WITHOUT PRIOR APPROVAL OF THE SUPERINTENDENT. FOR ALL OTHER CONCRETE
MEMBERS NO PENETRATION, CHASES OR EMBEDMENT SHALL BE MADE WITHOUT PRIOR APPROVAL
OF THE SUPERINTENDENT,

CONDUITS CAST INTO CONCRETE MEMBERS SHALL BE SPACED AT MAXIMUM DISTANCE POSSIBLE
AND UNDER NO CIRCUMSTANCES CLOSER THAN A CLEAR SPACE SPACING OF TWICE THE LARGER
CONDUIT DIAMETER FROM PARALLEL REINFORCEMENT OR ANY OTHER CONDUIT.

ALL REINFORCEMENT SHALL BE SECURELY SUPPORTED IN ITS CORRECT POSITION DURING
CONCRETING BY APPROVED PLASTIC TIPPED BAR CHAIRS, MAXIMUM CENTRES OF SUPPORTING
CHAIRS SHALL BE 600mm FOR FABRIC, 600mm FOR BARS UP TO 12mm, %00mm FOR BARS lémm
AND GREATER.

CONSTRUCTION BREAK LOCATION AND DETAILS SHALL BE APPROVED BY THE SUPERINTENDENT
PRIOR TO COMMENCEMENT,

THE FACE OF ALL CONCRETE AGAINST WHICH NEW CONCRETE IS TO BE CAST IS TO BE
THOROUGHLY MECHANICALLY SCABBLED, FULLY EXPOSING THE AGGREGATE MATRIX.

ALL CONCRETE SURFACES ARE TO CURED FOR SEVEN DAYS AFTER CASTING USING A METHOD
APPROVED BY THE SUPERINTENDENT.

FIRST SLAB BAR IS TO BE POSITIONED MAXIMUM |00mm FROM FACE OF BEAMS, R.C. WALLS AND
SLAB THICKENING PARALLEL TO BAR,

EXACT SIZE AND LOCATION OF PENETRATIONS ARE TO BE OBTAINED FROM WORKSHOP DRAWINGS
PRIOR TO SCHEDULING OF REINFORCEMENT, AND ARE NOT TO EXCEED DIMENSIONS WHERE SHOWN
ON STRUCTURAL DRAWINGS,

REINFORCEMENT IS SHOWN DIAGRAMMATICALLY AND NOT NECESSARILY IN TRUE PROJECTION,

UNDER NO CIRCUMSTANCES IS REINFORCEMENT TO BE CUT ON SITE TO CLEAR PENETRATION
WITHOUT APPROVAL BY THE SUPERINTENDENT, DISPLACE REINFORCEMENT SLIGHTLY AS
NECESSARY TO CLEAR BLOCKOUTS.

SPLICES IN REINFORCEMENT SHALL BE MADE ONLY IN THE POSITIONS SHOWN OR AS OTHERWISE
APPROVED BY THE SUPERINTENDENT.

WELDING OF REINFORCEMENT SHALL NOT BE PERMITTED WITHOUT APPROVAL BY THE
SUPERINTENDENT.

REINFORCEMENT SHALL BE BENT COLD IN ACCORDANCE WITH AS3600 EXCEPT WHERE APPROVAL
BY THE SUPERINTENDENT. NO REBENDING SHALL BE PERMITTED UNLESS APPROVED BY THE
SUPERINTENDENT.

 

RIENMAC ery ito

ABN. 52 010 666 430 AC.N. 010 666 430
CONSULTING CIVIL &
STRUCTURAL ENGINEERS

SUNSHINE COAST OFFICE:
SUITE 5, FIRST FLOOR,
SAINT CIRINO, F
[37 BRISBANE ROAD, Email
(PO BOx 144)
MOOLOOLABA @LD 4557

 

P:- (07) 5478 250d
(07) 5444 |I5q
[email protected]
[email protected]!
Web:- www.rienmac. bi:

 

CLIENT:
CONNETIVITY PTY LTD
PROJECT:

PROPOSED UNITS

LOT 219 CORSAIR CRESENT
SUNRISE BEACH @LD 4567

REAL PROPERTY DESCRIPTION # COUNCIL:
LOT 219, RP 135364

PARISH OF WEYBA, COUNTY OF MARCH
SUNSHINE COAST REGIONAL COUNCIL
DRAWING TITLE:

CONCRETE NOTES

 

Designed: PLR Drawn:

LR

 

SCALES:

 

Engineer: PLR |DATE: 25 MAY I5

 

5330 | 519

 

 

A

 

 

rin he Band iy Cees tm wt | JOB NUMBER DWG No. | ISSUE
PETER RIENECKER - RPEQ@ 2088 DO NOT SCALE OFF DRAWINGS, | A3 |SHEET !4 OF 2i |CHECKED: PLR

 

 

 

 

 

Page 20

 

SHEAR CAPACITY

 

 

 

 
  
  

 

 

 

 

 

 

 

TABLE 8.18

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Email:- info@rienmac. biz

Web:— www ,rienmac, bi:

P:- (07) 5478 250d
F:- (07) 5444 158

info@rienmac,ne'

 

RA FTERS, JO| STS or TRUSSES (KN) ( Ch) prywoop SHALL BE NAILED TO FRAME USING 30x2.80 FLATHEAD NAILS OR EQUIVALENT. >)
TO BRAC | NG WAL L Unseasoned Seasoned FOR METHOD A, MI2 RODS SHALL BE USED AT EACH END OF SHEATHED SECTION TOP PLATE TO BOTTOM
AAA EINE ENT ONAL Timber Timber PLATE/FLOOR FRAME. METHOD B HAS NO RODS BUT SHEATHING SHALL BE NAILED TO TOP AND BOTTOM PLATES
AND ANY HORIZONTAL JOINTS @50mm CENTRES.
TAB L E & . 22 J2 J3 | J4 JD4 | JD5} JDe MINIMUM PLYWOOD THICKNESS (mm) BRACING
ZL HORIZONTAL BUTT JOINTS PERMITTED, PROVIDED NAIL CAPACITY
(— (b) TRUSSED ROOFS BOLTS FIXED TO NOGGING AT S = [50mm CENTRES FOR METHOD A, (kN/m)
NAILS OR SCREWS THROUGH THE TOP PLATE SHALL BE or S = 50mm CENTRES FOR METHOD B.
PLACED IN HOLES THAT PERMIT FREE VERTICAL Mlo 64/41 |26 143 130] 20 150 50 GRADE. STUD SPACING (mm)
MOVEMENT OF THE TRUSSES. : : : : : : a 00
PROVIDE CLEARANCE 450 600
90x35mm F8 NOGGING (ONE BOLT) WHERE ROOF |S M2 76 |4.9)3.1 | 511 36) 25 8 7 q
120x35mm F8 NOGGING (TWO BOLTS) TRUSSED, _ 6 i ; ;
2/MI0} 12 8 51 184 |5.9] 4 3B g Fld 4 ‘6 metop A
BRACING WAL. J avmi2] 13 | 4.3 }el 98 |7 | 4.4 7 ‘ “8 6A
LAA BATTEN SCREWS Lo FASTENER SPACING, $ (mmm) METHOD B:
6.0
I/No 14 48 1351)25 135 |25 18 TOP AND BOTTOM PLATE:
: . . . . . - METHOD A 150
[<q TYPE |7 - METHOD B 50
Ne 9.7 |} 6.9749 16.9 [49] 3.6 VERTICAL EDGES 150
3/No 14 | [3 93166 194.8 | 7.4 5.4 f i INTERMEDIATE STUDS 300
SCREWS or BOLTS AS TYPE 17 SHEATHED PANELS SHALL BE
PER TABLE, CONNECTED TO SUBFLOOR.
FRAMING ANCHORS (LEGS
Kot BET) t/2arod oe meg a our 2
~te) FACE. END OF SHEATHED SECTION.
©) NAILING PLATES OR FRAMING ANCHOR NAILS
(LEGS NOT BENT) TO EITHER END OF METHOD A METHOD B
NOGGING 672 Brame NAILS EACH FACE 4/3.050| 5.0 | 3.6 | 2.5 | 3.6 | 3.0 22 NOTE: FOR PLYWOOD FIXED TO BOTH SIDES OF THE WALL, SEE
OR 2/No 14 TYPE I7 BATTEN SCREWS : 1
EITHER END. 6/3.050| 6.6 |4.7|3.4 |5.0 | 4.2} 31 \_ LAUSE 8.3.6.5. JD
fonornm NOGEING. | 4733301 5.6 | 4.0 |28 | 4.0 13.3] 25 SE
: eee jee {ee = : PLY BRACING WALL DETAILS
6/3,330} 7.4 153 )3.7 15.5 |46) 3.5 RIENMAC PTY LTD
BOLTS THE BOTTOM OF ALL BRACING WALLS ARE TO BE A.B.N. 52 010 666 430 A.C.N. 010 666 430
FIXED TO THE FLOOR FRAMING AS PER TABLE 51 Ua NUNES
Mo 64 | 4l [26 [43 | 3.0] 2.0 6.23 AND 8.24 OF ASI664.2. SUNSHINE COAST OFFICE:
SUITE 5, FIRST FLOOR,
MI2 7.6/4.9 }31 | 5.1 3.6) 2.5 SAINT. CIRINO,
Mée | 13 |80]51 }84 | 5.4) 4.0 (oO oe
M ABA 4557
BATTEN SCREAS eSherivity ry LTD
NAILED OR BOLTED
BRACING WALL. AS PER TABLE, Net 9.7 16.9149 16.9 | 4.9] 3.6 eROLECT.
PROPOSED UNITS
3/No 4) (3, | 9.2 |66 19.8 | 7.4] 5.4
TYPE |7

 

 

(f) RAFTERS FOR CEILING
JOISTS.

      
   
   

FRAMING ANCHOR (LEGS
NOT BENT) 6/2.8mmo
NAILS EACH FACE.
gs
N

BRACING WALL.

 

XN

6.5 |46)3.3 |49 |4 3.1

 

 

 

 

 

 

 

 

R:\rienmacfiles\Rienmac\15\Large\15330 - Lt 219 Corsair Cr, Sunrise Bch - Steve-Dianne Selby - Des Crawford\15330.dwg, Model,
26/11/2015 9:25:34 AM, L Roth, Rienmac Pty Ltd, CutePDF Writer, A3, 1:100

 

LOT 219 CORSAIR CRESENT
SUNRISE BEACH @LD 4567

REAL PROPERTY DESCRIPTION # COUNCIL:
LOT 219,

PARISH OF WEYBA, COUNTY OF MARCH
SUNSHINE COAST REGIONAL COUNCIL
DRAWING TITLE:

BRACING # TIEDOWN DETAILS

RP 135364

 

 

 

Designed: PLR Drawn: LR
SCALES:
Engineer: PLR |DATE: 25 MAY [5

 

15330

520| A

 

 

 

 

 

 

 

rin he Cand Sy Eee wt | JOB NUMBER DWG No. | ISSUE
PETER RIENECKER - RPEQ@ 2088 DO NOT SCALE OFF DRAWINGS, | A3 |SHEET 20 OF 21 |CHECKED: PLR

 

 

Page 21

 

APPENDIX A

 

REQUIREMENTS FOR SITE DRAINAGE,

 

 

 

 

LAYOUT FOR WET SITE

 

v

TO OUTFALL

 

2 c«—-—-
S
ola DQ
Oe} =)
Wx Ss
O/~
y efi
AX
Vv
TO OUTFALL
ae
8 Ke
s/s
2
Fe
Yv ~
B. DRAINAGE
TO OUTFALL TO OUTFALL

A, TYPICAL DRAINAGE LAYOUT

 

 

 

 

 

L TO OUTFALL
C. DRAINAGE LAYOUT FOR CUT & FILL SITE

 

 

THE SITE MUST BE
ACCORDANCE WITH THE ABOVE PRINCIPLES

2. PROVISION OF PAVING, SURFACE GUTTERING OR UNDERGROUND PIPING WILL

DRAINAGE.

4. DRAINAGE

R:\rienmacfiles\Rienmac\15\Large\15330 - Lt 219 Corsair Cr, Sunrise Bch - Steve-Dianne Selby - Des Crawford\15330.dwg, Model,
26/11/2015 9:25:52 AM, L Roth, Rienmac Pty Ltd, CutePDF Writer, A3, 1:100

 
   

— > 7 La cot
Ve
\
\
) GROUND OUTSIDE
~~ ) RESIDENCE TO FALL TO

EARTH DRAIN AT 1:100

EARTH DRAIN REQUIRED IF
FACE IS LIKELY TO SCOUR

N\-

~~ EARTH DRAIN

(FALL 1:100)

SLAB CAST ABOVE GROUND
LEVEL TO SUIT DRAINAGE
CONDITIONS AND FALLS TO
SEWERS AS PER LOCAL
AUTHORITY ORDINANCES.

SO GRADED AND DRAINED THAT THE WATER IS SHED FROM THE BUILDING PLATFORM IN

- ALL ASSIST IN ACHIEVING GOOD

3. GOOD DRAINAGE MUST BE MAINTAINED THROUGHOUT CONSTRUCTION AS WELL AS AFTER PRACTICAL COMPLETION

MUST NOT BE DIRECTED AT AN ADJACENT LOT IN A CONCENTRATED FORM.

COMPACTED CUT
MATERIAL

CHECK a on

 

APPENDIX B SITE PREPARATION AND EARTHWORKS.

 

 

 

BANK WIDTH [800mm OR AS FOLLOWS FOR VARIOUS SOIL TYPES
WELL GRADED GRANULAR FILLS.

  
  
    

A- 1.5 d - WEATHERED ROCK :
B- 2.0 d - CLAYS : SILTY, SANDY AND GRAVELLY CLAYS
C- 3.0 d - SILTS : SANDS AND SOFT CLAYS

FLOOR SLAB

 

 

|
DRAINAGE SYSTEM
REFER APPENDIX A

 

WHERE 'd' EXCEEDS |200mm, REFER TO ENGINEER FOR
RE-APPRAISAL OF FOOTING AND SLAB DESIGN,

CAN NOT BE ATTAINED DUE TO SITE CONSTRAINTS
ETAINING WALL AND/OR PIERS TO NATURAL GROUND.

WHERE BANK WIDTHS SPECIFIED ABOVE
REFER TO ENGINEER FOR DESIGN OF

 
 

NOTES:-

 

 

THE CONFINES OF THE BUILDING SITE ARE TO BE RIPPED AND ALL VEGETATION REMOVED FROM
THE BUILDING AREA. GRUB HOLES ARE TO BE BACKFILLED AND COMPACTED AS INDICATED IN NOTE
2.

    

2. WHERE SLAB AND FOOTINGS ARE TO BE FOUNDED IN FILL, BUILDING PLATFORMS SHALL BE BUILT
UP IN LAYERS AND COMPACTED TO ATTAIN A MINIMUM UNIFORM FIELD DENSITY OF 98% STANDARD
COMPACTION FOR COHESIVE FILL MATERIAL AND A MINIMUM DENSITY INDEX OF 70% RELATIVE TO TEST
E6.1 FOR GRANULAR (NON-COHESIVE) FILL MATERIAL.

3. SOIL MOISTURE CONTENT SHOULD BE MAINTAINED NEAR OPTIMUM DURING COMPACTION, SMOOTH
DRUM ROLLERS MAY BE USED FOR GRANULAR FILLS, VIBRATING SHEEPFOOT ROLLERS ARE

RECOMMENDED FOR CLAYS.

THE QUALITY OF COMPACTION SHOULD BE TESTED BY A RECOGNISED TESTING AUTHORITY - IT IS THE
BUILDER'S RESPONSIBILITY TO ENSURE THAT THE TES

 

ACROSS THE WHOLE PLATFORM

 

RIENMAC ery ito

ABN. 52 010 666 430 AC.N. 010 666 430
CONSULTING CIVIL &
STRUCTURAL ENGINEERS

SUNSHINE COAST OFFICE:
SUITE 5, FIRST FLOOR,
SAINT CIRINO, F
[37 BRISBANE ROAD, Email
(PO BOx 144)
MOOLOOLABA QLD 4557

 

P:- (07) 5478 250d
(07) 5444 |I5q
[email protected]
[email protected]!
Web:- www.rienmac. bi:

 

CLIENT:
CONNETIVITY PTY LTD
PROJECT:

PROPOSED UNITS

LOT 219 CORSAIR CRESENT
SUNRISE BEACH @LD 4567

REAL PROPERTY DESCRIPTION # COUNCIL:
LOT 219, RP 135364

PARISH OF WEYBA, COUNTY OF MARCH
SUNSHINE COAST REGIONAL COUNCIL
DRAWING TITLE:

APPENDIX A é B

 

 

 

 

 

 

 

 

JILDE TY TO ENSURE THAT THE TEST (or TESTS) GIVE AN ACCURATE INDICATION Designed: PLR Drawn: LR
OF THE QUALITY AND DEGREE OF COMPACTION OF THE FILL THROUGHOUT THE ENTIRE DEPTH AND SCALES:
Engineer: PLR |DATE: 25 MAY [5
Inet ote eis mitt wttn | JOB NUMBER DWG No.| ISSUE
PETER RIENECKER — RPEQ 20881 [po nor scace ofr prawnes. | AS [SHEET 21 OF 2 (CHECKED: PLR

 

 

 

 

 

Used in these records

About this file

File size
2.9 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

20150426 - Engineering Drawings.pdf · 2.9 MB (large file)