Council archive · source document
20150426 - Engineering Drawings · 132007.2062
Attached to the e-mail OPW16/0050 - Operational Works Application 1 of 2.
THICKNES “ WATER LEVEL ——} rw a 2 > “ TT Pd 8 TT ——1/S|2 EXTRA TYPICAL. - 350 MAX ° 16 REFER PLAN = WATERPROOF < HEIGHT H_ | THICKNESS T LS CEMENT RENDER, pL COPING BEAM 1000 - |500 200 a7 REINFORCEMENT 1500 - 2000 250 ' AS DETAILED AS DETAILED. 150 PLACED CENTRALLY. 350 MAX 4/512 300 MAX 3/512 350 MAX fp 275 MIN REFER PLAN WATER LEVEL} 75 WATER LEVEL ws F42 MESH 25 COVER TO OUTSIDE FACE HEIGHT H 500 LAP Sl2 AT 300 | 600 MIN 200 MIN 2/5|2 —>r REINFORCEMENT AS DETAILED 50 COVER TO WATER FACE REMAINING DETAILS AS BEFORE. REINFORCEMENT AS I=— DETAILED 50 COVER TO WATER FACE. REMAINING DETAILS AS PER ABOVE. IN GROUND DETAIL OUT OF GROUND DETAIL COPING BEAM TYPE A POOL CONSTRUCTION SPECIFICATION |. WORKMANSHIP € MATERIALS TO BE IN ACCORDANCE WITH AS2783 CONCRETE SWIMMING POOL CODE AND LOCAL AUTHORITY'S REQUIREMENTS. 2. POOL FILLING € SOIL BACKFILLING NOT TO BE CARRIED OUT UNTIL WALLS ¢ FLOOR HAVE REACHED DESIGN STRENGTH. 3. 50mm LAYER OF 22mm GRAVEL TO BE PLACED UNDER POOL FLOOR. 4. ALL CONCRETE TO BE PRESSURE APPLIED BY 'PRESSURECRETE' METHOD WITH AN AVERAGE COMPRESSIVE STRENGTH OF 32MPa AT 28 DAYS. RIENMAC ery ito ABN. 52 010 666 430 AC.N. 010 666 430 CONSULTING CIVIL & STRUCTURAL ENGINEERS SUNSHINE COAST OFFICE: ALL CONCRETE ON PLAN TO BE 300mm RADIUS UNLESS NOTED OTHERWISE. ALL REINFORCEMENT TO BE HOT ROLLED DEFORMED BARS 'S' é 'Y', SUITE 5, FIRST FLOOR, SAINT CIRINO, [37 BRISBANE ROAD, (PO BOx 144) MOOLOOLABA @LD 4557 P:- (07) 5478 250d F:- (07) 5444 lI58 Email:- info@rienmac. biz [email protected]! Web:- www.rienmac. bi: 400 000 000 | a SS THICKNE POOL FOOTING DETAIL FOR FLOOR <G00_IN GROUND R:\rienmacfiles\Rienmac\15\Large\15330 - Lt 219 Corsair Cr, Sunrise Bch - Steve-Dianne Selby - Des Crawford\15330.dwg, Model, 26/11/2015 9:24:05 AM, L Roth, Rienmac Pty Ltd, CutePDF Writer, A3, 1:100 7. CROSS RODS NOT NOTED TO BE SI2 @ 300 CRS. 8. ALL BARS TO HAVE A SPLICE LENGTH OF 600mm, UNO. 9. MAIN REINFORCEMENT TO HAVE 65mm COVER TO GROUND FACE. WHERE A SECOND LAYER OF REINFORCEMENT IS USED COVER IS TO BE 40mm TO WATER FACE, COVER TO TOP STEEL OF COPING TO 25mm FROM TOP OF CONCRETE. COVER TO BOTTOM STEEL IN COPING IS TO BE 40mm FROM BOTTOM OF CONCRETE. 10. SPLICES IN ADJACENT REINFORCEMENT BARS TO BE STAGGERED. ll, DEEP END TO HAVE AT LEAST 0.3m OF FIRM, NATURAL SOIL OR EQUIVALENT RETAINING WALL, ETC AS SUPPORT. 12. SUPPORTING SOIL TO BE SOUND NATURAL SOIL OR WELL COMPACTED FILLING WITH BEARING CAPACITY AT ANY DEPTH NOT LESS THAN l00kPa. 13. DESIGN TO BE MODIFIED IF EXCESS GROUND WATER IS ENCOUNTERED DURING EXCAVATION. 14. ALL DIMENSIONS ON SITE PLAN SHOWING THE POSITION OF THE POOL ARE TO THE WATER FACE. I5. POOL OWNER TO BE INFORMED THAT AN ELEMENT OF RISK TO THE POOL STRUCTURE IS INVOLVED IF THE POOL IS EMPTIED. CLIENT: CONNETIVITY PTY LTD PROJECT: PROPOSED UNITS LOT 219 CORSAIR CRESENT SUNRISE BEACH @LD 4567 REAL PROPERTY DESCRIPTION # COUNCIL: LOT 219, RP 135364 PARISH OF WEYBA, COUNTY OF MARCH SUNSHINE COAST REGIONAL COUNCIL DRAWING TITLE: PETER RIENECKER - RPEQ 2088 DETAILS Designed: PLR Drawn: LR SCALES: 1:20 Engineer: PLR |DATE: 25 MAY [5 pamsion Hom Riemnec Coiling Engreers [JOB NUMBER DWG No. |_ISSUE DO NOT SCALE OFF DRAWINGS, | A3 |SHEET le OF 21 |CHECKED: — PLR
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
20150426 - Engineering Drawings.pdfRelated documentApplication case desk ↗
20150426 - Engineering Drawings.pdfRelated documentApplication case desk ↗
About this file
- File size
- 2.9 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.