Log in to see the plans as drawn A B C D E F G
2,300 5,910 2,800 8,590 8,180
REN BLK hood MR AFW CS FC REN BLK AFW FG AFWhood AFD AFW CS REN WT TIM AFW REN BLK AFW CS REN TD PF PF FSC
flue
MASTER
MASTER BED
ENS
T.O.W R.L 16.230
FFL 15.910 FFL 15.910
UPPER LEVEL UPPER LEVEL
STUDY/ PTY KITCHEN DINING
PDR T.O.W R.L 14.830
T.O.W R.L 14.530 GARAGE retractable awning
NGL
BINS DRIVE WAY
FFL 12.970 NGL
FFL 12.970
MAIN LEVEL TD MAIN LEVEL
ABBYS
BATHROOM
ROOM
FFL 10.770 FFL 10.770
LOWER LEVEL EXISTING LOWER LEVEL
POOL FFL R.L 10.070
SOUTH ELEVATION NGL
SCALE 1:100 @ A3
WD.60% Work In Progress
issue issue / amendment
11.08.22 LF AB JH
EXT. FINISHES LEGEND FCA fibre cement awning. PF compliant pool fencing
issue date
client
drawn by
AS aluminium screen. FC fibre cement ext. cladding. PW parapet wall. Ingrid & Nick Hutton
project
AL aluminium louvres, refer sched. FG fascia gutter. PS patio slab. Hutton Plover St
location
ASD aluminium sliding door. FT1 floor tile (no refers to type). PV photovoltaic cells. 24 Plover St Peregian Beach
AFD aluminium framed door. fire fireplace RWT rain water tank. SOUTH ELEVATION
aluminium framed window. flue kit silicone butt jointed glass.
SOUTH ELEVATION 3D
AFW flue SBJ
Aboda Lee Foster • director Scott Falconer • director
Design p - 0424 620 247 p - 0431 267 157
Group e - [email protected]
BA sun control battens, refer detail. GS garage slab. SP structural post, refer engineer. the aboda design group trust
e - [email protected]
Level 2 1794 David Low Way Coolum Beach,
SCALE N.T.S. ABN 56 266 884 746 Q. 4573. PO box 2449 Noosa Heads Q 4567
BAL1 balustrade-(no refers to type). HWS hot water service. SF structural footing, ref. eng. t/a aboda design group • BSA License -150580097 • www.aboda.com.au
• This drawing is to be read in conjunction with engineers drawings & reports • Construction
BLK masonry blockwork. HR handrail. TIM timber cladding. to comply with all relevant SAA & NCC Codes & standard Bldg By-law 1975 & as amended •
Copyright for design & drawings remain the property of the authors • Verify all dimensions on
- site prior to commencement of any works • These drawings are not to be used for scaling.
C carpet LPG LPG gas bottle. TD timber deck. APPROVED PLAN scale as shown @ A3 issue
TF timber floor. drawing no.
CS concrete slab. NGL NRG board
MCU22/0016 WD.
timber framed door
WD.502
TFD
down pipe. metal roof - (no refers to type).
NOOSA COUNCIL
DP MR1
driveway slab. natural ground line.
VER vergola. 60%
16 AUGUST 2022
DS NGL