Skip to the record
Search everything, all in one place.

Council archive · source document

OPW16/0150 - Approved Plans

of 2

Plans and drawings: the text below has words only, no drawings.

Log in to see the plans as drawn
                                                                                                                                                                                                                -

                                                                                                                                                                                          NOOSA COUNCIL
                                                                                                                                                                                          APPROVED PLAN
                                                                                                                                                                                       OPW16/0150 29 JUL 2016
                                                                                                                                                                                                                        LINDSAY CONSULTING PTY
                                                                                                                                                                                                                                           LTD




                                                                                                                                                                                           STREET
                                                                                                                        EXISTING FOOTPATH
                                                                                EXISTING SEWER LINE




                                                                                                                                                                                           HENDERSON
Saw cuts every 4.5m
crs and Key Joints
every 3 saw cut.



                                                                                                      SMH
                                                                                                      SL35.80
                                                                                                      IL 34.36


                                                                                                                                                                                                        DRIVEWAY
                                                                                                                                                                                                        LONGSECTION 1




                                                                                                                                            5600mm at Kerb to match existing
      New Concrete




                                                     4600mm to match existing
      driveway 125mm thick.
      SL72 fabric centrally
                                                                                                      New Concrete
                                                                                                      driveway 125mm thick.
                                                                                                      SL72 fabric centrally
                                                                                                                                                                                            Builder to confirm if
                                                                                                                                                                                            any re-instate of kerb
                                                                                                                                                                                            and channel is
                                                                                                                                                                                            required.



                                                                                                                                                                               600mm landscape
                                                               Existing Neighbouring
                                                               Timber retaining wall                                                                                           strip
              Existing timber retaining wall to be
              replaced with new Blockwork




                                                                                                                        EXISTING FOOTPATH
              retaining wall to builders             Existing Water meter
              specifications and continue out to
              the footpath.

                                                                                                                                                                                 All AHD levels provided are
                                                                                                                                                                                 existing levels provided by
                                                                                                                                                                                 owner.
Full text of the other 1 page

Page 2

                                                                                                                  -

                                                                                                           NOOSA COUNCIL
                                             125mm THICK CONCRETE                                          APPROVED PLAN
                                                     DRIVEWAY, N25
                                                                                                        OPW16/0150 29 JUL 2016
Existing Sewer Main Dia 150 UPVC
                                                                                                                                 LINDSAY CONSULTING PTY
                                                                                                                                                    LTD

    UIL 34.36. Depth of pipe 1.44m.
630mm of cover between underside
         of concrete and top of pipe.


                                                                      ALL SERVICES HAVE BEEN LOCATED
                                                                     BY ALL UNDER GROUND PIPE & CABLE
                                                                           LOCATORS AND CONFIRMED BY
            TOK 34.83                                                              RELEVANT SERVICES


                                        SM

Used in these records

About this file

File size
215 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

OPW16_0150 - Approved Plans.pdf · 215 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.