Council archive · source document
RFI - Amended design plans · 51993.564.01
Plans and drawings: the text below has words only, no drawings.
Very large file (12.6 MB): may take a few minutes to open.
DANYA COOK TOWN PLANNING
Appendix B
Amended Design Plans
Prepared by Suncoast Building Design
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 12 pages
Page 2
PROPOSED ADDITIONS & ALTERATIONS
TO EXISTING RESIDENCE
Noakes
1/10 Sunseeker Cl
Noosaville
0 1m 5m
Revision Proposed Residence Address Client Scale
This plan shall remain the sole property of Suncoast Building Design and must not be 1/10 Sunseeker Cl Noakes
given, lent, hired out or otherwise disposed of or copied without the written permission of Rev A - 27.06.23 - Proposed Gazebo in leiu of Alfresco
Suncoast Building Design.
Noosaville
Drawn Page No.
Note: all dimensions/engineer details and relevant information to be checked and
confirmed by builder /client. Suncoast Building Design does not take any responsibility MM/SB 1
after drawings have been checked and confirmed by builder/client or construction has Suite 7 / 10 Grebe St, Peregian Beach mob: 0401565629
commenced. [email protected] Job No. Date Stage Drawing
www.suncoastbuildingdesign.com.au mob: 0491289102
20.141 27.06.23 DA Approval Cover Page
Page 3
owner responsibility notes:
-it is the responsibility of the owner to provide all weather access to building site
-it is the responsibility of the owner to undertake tree removal, including obtaining associated permits, and
to provide a site clear of any vegetation
site notes: or debris to satisfaction of builder prior to commencement of site works
-position of dwelling to be confirmed by client prior to any -it is the responsibility of the owner to undertake removal of any site spoil/stock piles to the satisfaction of
site works the builder prior to commencement
-all storm water, down pipes, rain water tanks & site of building works or a variation will be incurred for associated costs
drainage to be sized & located by the hydraulic - any walls constructed on the boundary, will require the client/s
consultant/plumber in accordance with ncc vol 2 3.1.3.5 to remove the boundary fence prior to construction
& 3.5.2 and qdc mp4.2/local planning scheme house
code
-builder to ensure that actual sewer line and manhole
positions match those as shown -based on local authority
9
78
1.
documents. any discrepancies must be brought to the note: all windows and gates opening into pool enclosure to comply with pool safety requirements (all louvres
attention of builder and resolved prior to commencement max, 100mm blades) pool fencing to specialist contractors specifications - plans shown indicative only.
T1
of construction
-builder to determine appropriate platforming method on pool fencing must comply with australian standard as 1926.1 & qdc part 3.4.
site prior to commencement of any works. finished floor fencing to be minimum 1200mm high with self-closing gate as per requirements. provide resuscitation sign.
level is to be above the minimum level as per local provide pool fencing certificate(s).
authorities requirements & to comply with ncc vol 2
3.1.2.3 pool safety barriers must comply with the building act 1975, building regulation 2006, qdc mp3.4 -
-the finished surface immediately surrounding the swimming & pool barriers and australian standards as 1926.1 & as 1926.2.
buildings to comply with ncc vol2, 3.1.3.
-surface drainage is to discharge evenly within the site
and without nuisance to adjoining properties.
-all sub-floor areas must be graded to avoid the ponding
of water.
-cut and fill batters not to exceed a maximum slope as
per ncc table 3.1.1.1 for the site specific soil type, refer 231°46'10"
also to ncc clause 3.2.2.4 for slab edge support on 35.002
sloping sites.
-1000 maximum high timber retaining walls with 65∅ ag
pipe behind (to discharge to stormwater line) and
granular backfill behind, to be wholly contained within the
site only if indicated on the plans.
'0"
1°7
-the height of fences, including the height of retaining
0
.50
17
walls are not to exceed 2.0m above finished ground level,
12
only if indicated on the plans and to local authority
approval.
all proposed finished floor levels to be checked and
verified
4
on site to comply with minimum building requirements,
14
4.940
2.
5 2.140
flood levels 68
322°56'15"
2.
UNIT 2
13.501
5
and local council regulations, prior to construction NEIGHBOURING DWELLING 04
2.
25
4
2.
8
67
5,3
2.
sewerage to local council design roof water to
7
82
77
1.
discharge into rainwater tank and overflow into EXISTING 216.6 m2 7.594
existing council system 7.626 9
6.947 95
7.607 7.591 6 1.
28
2
50
3
37
6 2.
9. 6. 387
6.41
0 0 2.
0
66 43 EXISTING PARTY WALL EXISTING PARTY WALL
note: built-to-boundary allotments only - 2. 2.
150
5 6 5
612.54963
2.544 21
surveyor setout required, and certificate to be submitted 8.
1
48 7. 7.
2.
7.619
to building certifier prior to final approval. ensure no PROPOSED 54
4 7.6117.6
7.61115
2.
encroachment over boundary, including gutter GAZEBO
1
43 2.543 2.551
2. 4
2.162
7
70 70
14.9 m2 8. 8.
UNIT 1
224°20'5
7,926
8 "
34
note: all windows and gates opening into SUBJECT DWELLING
5 69
50 .5
1
46
2. 2.
17 17.496
pool enclosure to comply with pool safety 0
8.
19
2. 2 2. 1
requirements (all louvres max, 100mm blades) pool FF
L
fencing to specialist contractors specifications - plans 7 3
FFL:2.40 4.936 4.9
4.824
shown indicative only. 65 .6
2 9 71
7. 6.9817 6.763 2.
48 1.965 2.050
5
00
46
3 2.
7.623 54 7.585 7.574
2.
all existing sewers and easements on site
1,5
should be located prior to construction
4.900
36 4.902
328°0'0"
66
4.679
4.947 4.947 PROPOSED CARPORT 4
64
2.
30.5 m2
2,3
note: original detail land survey 0
2.
54
undertaken by: Cadcon 33 9
0
47 1
46
1.2 m2
2. 8
32.6
5" 5.171 2.
43
2.1 m2 2. 0
2.
48 2.
40
34'2 5.186
75°
5,18
3
37
1.982 2.062 83
1.
4
4.947 4.937 4.934
1,6
2.059
5"
5,
3
9
41
3.22
°0'4
2. 1.981
16
342
1
2 9
36 83
328°0'0"
2. 1.
6.000
2.065
2 3
39 22 1.980
2. 2.
5 3.
28 22
N 2.
LARGE TREES TO FRONT CORNER 2.090 10°1'2 3
OF SITE TO BE REMOVED 0"
5
1.989 83
2.080 1.
3.223
3.838 38°1'5 6.000
5"
2.0
73 1.974
52°2'17" 52°2'55"
2.062
2
2.006 2.061 837
4
1.947 11..83
8 1.939 .843 1
82 83 T2
1.887 1.1.933 1 1. 08
7
2 1.
5 7 1
82 81
1 82
6 80 .80 8 1. 1. 1.
81 1. 1 67
1. 1.
SITE AREA SCHEDULE:
SITE AREA: 740.5m2 (total)
SITE COVER: EXISTING 222.4m2 (30.03%)
EXISTING DEMO - 5.89m2 0"
PROPOSED ADDITION 3.3m2
5'3
2°4
6 26
PROPOSED CARPORT 30.5m2 .49
29
PROPOSED GAZEBO 14.9m2
PROPOSED TOTAL 48.7m2
PROPOSED TOTAL INC. EXISTING 265.21m2 (35.81%)
hws
COUNCIL: NOOSA COUNCIL hws
m/b
0 1m 5m
Revision Proposed Residence Address Client Scale
This plan shall remain the sole property of Suncoast Building Design and must not be 1/10 Sunseeker Cl Noakes 1:200
given, lent, hired out or otherwise disposed of or copied without the written permission of Rev A - 27.06.23 - Proposed Gazebo in leiu of Alfresco
Suncoast Building Design.
Noosaville
Drawn Page No.
Note: all dimensions/engineer details and relevant information to be checked and
confirmed by builder /client. Suncoast Building Design does not take any responsibility MM/SB 2
after drawings have been checked and confirmed by builder/client or construction has Suite 7 / 10 Grebe St, Peregian Beach mob: 0401565629
commenced. [email protected] Job No. Date Stage Drawing
www.suncoastbuildingdesign.com.au mob: 0491289102
20.141 27.06.23 DA Approval Site Plan
Page 4
UNIT 2
NEIGHBOURING DWELLING
EXISTING PARTY WALL EXISTING PARTY WALL
KITCHEN
DINING
LOUNGE
BED 1
b
a
0 1m 5m
Revision Proposed Residence Address Client Scale
This plan shall remain the sole property of Suncoast Building Design and must not be 1/10 Sunseeker Cl Noakes 1:100
given, lent, hired out or otherwise disposed of or copied without the written permission of Rev A - 27.06.23 - Proposed Gazebo in leiu of Alfresco
Suncoast Building Design.
Noosaville
Drawn Page No.
Note: all dimensions/engineer details and relevant information to be checked and
confirmed by builder /client. Suncoast Building Design does not take any responsibility MM/SB 3
after drawings have been checked and confirmed by builder/client or construction has Suite 7 / 10 Grebe St, Peregian Beach mob: 0401565629
commenced. [email protected] Job No. Date Stage Drawing
www.suncoastbuildingdesign.com.au mob: 0491289102
20.141 27.06.23 DA Approval Ground Floor Existing
Page 5
UNIT 2
NEIGHBOURING DWELLING
EXISTING PARTY WALL EXISTING PARTY WALL
KITCHEN
DINING
LOUNGE
BED 1
demolition notes:
- all demolition works shall be under the supervision of the
demolishing contractor or experienced foreman.
demolition shall commence at the roof working down
- all structures to be sured and propped and precautions
taken to avoid danger from collapse when structure is removed
b
a
- no wall or structure is to be left unattended or unsupported
in a way it may collapse or become in any way dangerous
- all temporary openings to be weatherproofed by builder
- any materials to be reused are to be stored on site so as not
to interfere with other trades
- all redundant underground services to be removed from
ground, cap services at suitable termination locations.
0 1m 5m
Revision Proposed Residence Address Client Scale
This plan shall remain the sole property of Suncoast Building Design and must not be 1/10 Sunseeker Cl Noakes 1:100
given, lent, hired out or otherwise disposed of or copied without the written permission of Rev A - 27.06.23 - Proposed Gazebo in leiu of Alfresco
Suncoast Building Design.
Noosaville
Drawn Page No.
Note: all dimensions/engineer details and relevant information to be checked and
confirmed by builder /client. Suncoast Building Design does not take any responsibility MM/SB 4
after drawings have been checked and confirmed by builder/client or construction has Suite 7 / 10 Grebe St, Peregian Beach mob: 0401565629
commenced. [email protected] Job No. Date Stage Drawing
www.suncoastbuildingdesign.com.au mob: 0491289102
20.141 27.06.23 DA Approval Demolition Plan
Page 6
2
3 1
4
project notes:
-
UNIT 2
NEIGHBOURING DWELLING
5,3
77
EXISTING PARTY WALL EXISTING PARTY WALL
FR BUILT IN STORAGE
0
150
KITCHEN
3,801 SITTING
GAZEBO DINING ENTRY
7,926
2135 stacker
LOUNGE
PDR 2109
FFL:2.40
770
00
1,5
c
820
WM/DR
LINEN
CARPORT
ROBE
BED 1
16
770
1,8
WIR ENS
ROBE
5,12
37
0
1,6
5,
12
8
b
a
0 1m 5m
Revision Proposed Residence Address Client Scale
This plan shall remain the sole property of Suncoast Building Design and must not be 1/10 Sunseeker Cl Noakes 1:100
given, lent, hired out or otherwise disposed of or copied without the written permission of Rev A - 27.06.23 - Proposed Gazebo in leiu of Alfresco
Suncoast Building Design.
Noosaville
Drawn Page No.
Note: all dimensions/engineer details and relevant information to be checked and
confirmed by builder /client. Suncoast Building Design does not take any responsibility MM/SB 5
after drawings have been checked and confirmed by builder/client or construction has Suite 7 / 10 Grebe St, Peregian Beach mob: 0401565629
commenced. [email protected] Job No. Date Stage Drawing
www.suncoastbuildingdesign.com.au mob: 0491289102
20.141 27.06.23 DA Approval Ground Floor Plan
Page 7
UNIT 2
NEIGHBOURING DWELLING
EXISTING PARTY WALL EXISTING PARTY WALL
80
745
FR BUILT IN STORAGE
1,182
2,9
2,840
3,320
2,240
4,090
4,090
3,100
5,745
90
2135 stacker
900
250
2109
5,0
00
90
770
c
1,170
90
850
1,053
820
WM/DR
5,380
90
5,080
LINEN
90
ROBE
3,740
2,980
2,740
770
2,230
6,000
ROBE
250
250
250
14,830 90 3,050 90 2,890 220
3,600 250 10,980 90 1,800 250 4,200 1,800
300
3,600 250 4,510 90 90 4,300 90 1,600 90 1,800 250 6,000
b
a
0 1m 5m
Revision Proposed Residence Address Client Scale
This plan shall remain the sole property of Suncoast Building Design and must not be 1/10 Sunseeker Cl Noakes 1:100
given, lent, hired out or otherwise disposed of or copied without the written permission of Rev A - 27.06.23 - Proposed Gazebo in leiu of Alfresco
Suncoast Building Design.
Noosaville
Drawn Page No.
Note: all dimensions/engineer details and relevant information to be checked and
confirmed by builder /client. Suncoast Building Design does not take any responsibility MM/SB 6
after drawings have been checked and confirmed by builder/client or construction has Suite 7 / 10 Grebe St, Peregian Beach mob: 0401565629
commenced. [email protected] Job No. Date Stage Drawing
www.suncoastbuildingdesign.com.au mob: 0491289102
20.141 27.06.23 DA Approval Ground Floor Dimension Plan
Page 8
2
3 1
4
project notes:
-
REMOVE DOOR AND REPLACE WITH
1224 SW, INFILL GAP AND MAKE GOOD
REMOVE DECK K S
OR
DW
OSE
OP
PR
NO
c
b
a
0 1m 5m
Revision Proposed Residence Address Client Scale
This plan shall remain the sole property of Suncoast Building Design and must not be 1/10 Sunseeker Cl Noakes 1:100
given, lent, hired out or otherwise disposed of or copied without the written permission of Rev A - 27.06.23 - Proposed Gazebo in leiu of Alfresco
Suncoast Building Design.
Noosaville
Drawn Page No.
Note: all dimensions/engineer details and relevant information to be checked and
confirmed by builder /client. Suncoast Building Design does not take any responsibility MM/SB 7
after drawings have been checked and confirmed by builder/client or construction has Suite 7 / 10 Grebe St, Peregian Beach mob: 0401565629
commenced. [email protected] Job No. Date Stage Drawing
www.suncoastbuildingdesign.com.au mob: 0491289102
20.141 27.06.23 DA Approval First Floor Plan
Page 9
notes:
3.5.1.2 Corrosion protection and compatibility
requirements for roofing
(a)Metal sheet roofing must be protected from
corrosion in accordance with Table 3.5.1.1.
(b)Where different metals are used in a roofing
system, including flashings, fasteners, guttering,
downpipes, etc., they must be compatible with each
other as described in Tables 3.5.1.2a to 3.5.1.2d and
(i)no lead materials can be used upstream from
aluminium/zinc coated materials; and
(ii)no lead materials can be used on roofs that form
part of a potable (drinking) water catchment area; and
(iii)no copper materials can be used upstream from
galvanised coated materials.
3.5.3.2 Materials
Gutters, downpipes and flashings must—
(a)be manufactured in accordance with AS/NZS 2179.1
for metal; and
(b)be manufactured in accordance with AS 1273 for
UPVC components; and
(c)be compatible with all upstream roofing materials in
accordance with 3.5.1.2(b); and
(d)not contain any lead if used on a roof forming part
of a potable water catchment area.
3.5.3.4 Installation of gutters
(a)Gutters must be installed with a fall of not less than
—
(i)1:500 for eaves gutters, unless fixed to metal fascias;
and
(ii)1:100 for box gutters.
(b)Eaves gutters must be—
(i)supported by brackets securely fixed at stop ends
and at not more than 1.2 m centres; and
(ii)be capable of removing the overflow volume
specified in Table 3.5.3.3a and Table 3.5.3.3b.
20°
FAL (c)Overflow measures in accordance with Table
L 3.5.3.4a
20°
FAL
L 3.5.3.5 Downpipes — size and installation
Downpipes must—
(a)not serve more than 12 m of gutter length for each
down pipe; and
(b)be located as close as possible to valley gutters;
and
00
(c)be selected in accordance with the appropriate
1,5
eaves gutter section as shown in Table 3.5.3.2a to
c Table 3.5.3.2c.
3.5.1.3 Minimum pitches for metal sheet roofing
profiles
2° FALL
metal roofing 5○ or more will be corrugated custom
orb uno
16
metal roofing between 2○ - 5○ will be trapezoidal
1,8
profile or similar
metal roofing at 1○ will be a concealed fastened
profile or similar
37
5,12
1,6
0
5,
12
8
b
a
0 1m 5m
Revision Proposed Residence Address Client Scale
This plan shall remain the sole property of Suncoast Building Design and must not be 1/10 Sunseeker Cl Noakes 1:100
given, lent, hired out or otherwise disposed of or copied without the written permission of Rev A - 27.06.23 - Proposed Gazebo in leiu of Alfresco
Suncoast Building Design.
Noosaville
Drawn Page No.
Note: all dimensions/engineer details and relevant information to be checked and
confirmed by builder /client. Suncoast Building Design does not take any responsibility MM/SB 8
after drawings have been checked and confirmed by builder/client or construction has Suite 7 / 10 Grebe St, Peregian Beach mob: 0401565629
commenced. [email protected] Job No. Date Stage Drawing
www.suncoastbuildingdesign.com.au mob: 0491289102
20.141 27.06.23 DA Approval Roof Plan
Page 10
notes:
wall cladding to be installed a per manufacturers
spec.
refer to job spec. for all colours/finishes
All openable windows where the floor below the
window is 2m or more above the surface beneath
& has a sill height less than 1.7m from ffl, will be
fitted with a device capable of restricting the
window opening in accordance with ncc 3.9.2.6 &
3.9.2.7
position of external lights & outlets not shown in
elevation
window sizes shown are nominal only & may vary
depending on manufactures specifications and
exact sizes
locations for all heating & cooling units, solar
panels, man holes & whirly birds and the like are
nominal only and subject to change as per final on
site location requirements by relevant supplier
FF - CL (5.100)
all barriers & hand rails to comply with ncc 3.9.2
proposed window to
replace sliding door
o/a height as per existing
FF- FL (2.700)
GF - CL (2.400)
3,088
2,450
UNIT 2
NEIGHBOURING DWELLING
GF - FL (0.000)
Elevation 1
FF - CL (5.100)
NO PROPOSED WORKS
proposed carport
proposed gazebo
FF- FL (2.700)
GF - CL (2.400)
3,117
3,115
2,546
GF - FL (0.000)
Elevation 2
0 1m 5m
Revision Proposed Residence Address Client Scale
This plan shall remain the sole property of Suncoast Building Design and must not be 1/10 Sunseeker Cl Noakes 1:100
given, lent, hired out or otherwise disposed of or copied without the written permission of Rev A - 27.06.23 - Proposed Gazebo in leiu of Alfresco
Suncoast Building Design.
Noosaville
Drawn Page No.
Note: all dimensions/engineer details and relevant information to be checked and
confirmed by builder /client. Suncoast Building Design does not take any responsibility MM/SB 9
after drawings have been checked and confirmed by builder/client or construction has Suite 7 / 10 Grebe St, Peregian Beach mob: 0401565629
commenced. [email protected] Job No. Date Stage Drawing
elevations www.suncoastbuildingdesign.com.au mob: 0491289102
20.141 27.06.23 DA Approval Elevations
Page 11
notes:
wall cladding to be installed a per manufacturers
spec.
refer to job spec. for all colours/finishes
All openable windows where the floor below the
window is 2m or more above the surface beneath
& has a sill height less than 1.7m from ffl, will be
fitted with a device capable of restricting the
window opening in accordance with ncc 3.9.2.6 &
3.9.2.7
position of external lights & outlets not shown in
elevation
window sizes shown are nominal only & may vary
depending on manufactures specifications and
exact sizes
locations for all heating & cooling units, solar
FF - CL (5.100) panels, man holes & whirly birds and the like are
nominal only and subject to change as per final on
site location requirements by relevant supplier
all barriers & hand rails to comply with ncc 3.9.2
NO PROPOSED WORKS
proposed carport
FF- FL (2.700)
GF - CL (2.400)
approx. form n.g.l
3,227
3,040
3,117
UNIT 2
NEIGHBOURING DWELLING
GF - FL (0.000)
Elevation 3
0 1m 5m
Revision Proposed Residence Address Client Scale
This plan shall remain the sole property of Suncoast Building Design and must not be 1/10 Sunseeker Cl Noakes 1:100
given, lent, hired out or otherwise disposed of or copied without the written permission of Rev A - 27.06.23 - Proposed Gazebo in leiu of Alfresco
Suncoast Building Design.
Noosaville
Drawn Page No.
Note: all dimensions/engineer details and relevant information to be checked and
confirmed by builder /client. Suncoast Building Design does not take any responsibility MM/SB 10
after drawings have been checked and confirmed by builder/client or construction has Suite 7 / 10 Grebe St, Peregian Beach mob: 0401565629
commenced. [email protected] Job No. Date Stage Drawing
www.suncoastbuildingdesign.com.au mob: 0491289102
20.141 27.06.23 DA Approval Elevations
Page 12
DANYA COOK TOWN PLANNING
Appendix C
Turning Manoeuvre Plan for the B99
Prepared by Contour Consulting Engineers Pty Ltd
Page 13
O SE
CL
R
KE
EE
NS
0 10 20 30 40 50m
SU
SCALE 1:1000 A3
UNIT 1
SUBJECT DWELLING
UNIT 2
EXISTING NEIGHBOURING
DWELLING
SU
SU
NS
NS
EE
EE
KE
KE
RC
RC
LO
LO
SE
SE
REVERSE DRIVE
SCALE: 1:200 (A3)
5.2
FRONT WHEELS (GREEN)
0.95 3.05
B99 Vehicle (Realistic min radius) (2004)
Overall Length 5.200m
Overall Width 1.940m
Overall Body Height 2.200m
Min Body Ground Clearance 0.312m
Track Width 1.840m 300mm CLEARANCE (BLUE)
Lock-to-lock time 4.00s VEHICLE BODY (RED)
Curb to Curb Turning Radius 6.250m
FORWARD DRIVE VEHICLE PROFILE TURNING PATH LEGEND
SCALE: 1:200 (A3)
CONTOUR
SUNSHINE COAST OFFICE NORTH LAKES OFFICE
A.B.N. 62 117 061 659
PLAN DETAILS:
Designed:
Drawn:
Checked:
Vert. Datum:
PB
SF
PB
AHD
PLAN AMENDMENTS:
Rev
A
B
Date
26-06-23
28-06-23
Comment
ISSUE FOR APPOVAL
SITE PLAN UPDATED
Alt Chkd RPEQ
SF
SF
PB
PB
BT
BT
TRAFFIC ASSESSMENT VEHICLE TURN PATH PLAN
AT 1/10 SUNSEEKER CLOSE, NOOSAVILLE
PLAN TITLE:
Suite 512 & 513, Level 5
Tower 2, 55 Plaza Pde
Maroochydore, Qld 4558
Suite 5i, Bld 5, Level 1
2 - 4 Flinders Parade,
North Lakes, Qld 4509 ISO 9001 UKAS
Hori. Datum:
Date:
MGA GDA 2020
JUNE 2023 FOR ROGER & CAROLYN NOAKES FOR APPROVAL - NOT FOR CONSTRUCTIO
MANAGEMENT
...................... This plan is Copyright. Other than for the purposes of and subject to the conditions prescribed under the Copyright Act, no part of it may in any form or by
Ph. (07) 5493 9777
www.ContourCE.com.au
[email protected]
Trading name of SN Registrars (Holdings) Ltd
SYSTEMS
Quality Assured International 3rd Party Accredited
8327 - RPEQ:-
(FOR & ON BEHALF OF CONTOUR C/E PTY LTD)
any means be reproduced, stored in a retrieval system or transmitted without the prior written permission of Contour Consulting Engineers. The plan shall not
be used for construction without prior written approval.
PLAN No: 3537 - SK01 REVISION: B
FILE LOCATION: C:\12DS\DATA\CCE2K16DC01\03537 - 1 - 10 SUNSEEKER CLOSE, NOOSAVILLE_31204\DESIGN - CIVIL\AUTOCAD\SKETCHES\3537 - SK01.DWG
Used in these records
RFI - Amended design plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 12.6 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.