                                                                                                                                                                                         UNIT 2
                                                                                                                                                                                 NEIGHBOURING DWELLING




                                                                                                                                                           EXISTING PARTY WALL                                                       EXISTING PARTY WALL




                                                                                                                                                                                                                    KITCHEN
                                                                                                                                                                                    DINING




                                                                                                                                                       LOUNGE




                                                                                                                                                                                                   BED 1




    demolition notes:
    - all demolition works shall be under the supervision of the
      demolishing contractor or experienced foreman.
      demolition shall commence at the roof working down
    - all structures to be sured and propped and precautions
      taken to avoid danger from collapse when structure is removed
                                                                                                                                                                                                                 b
                                                                                                                                                       a




    - no wall or structure is to be left unattended or unsupported
      in a way it may collapse or become in any way dangerous
    - all temporary openings to be weatherproofed by builder
    - any materials to be reused are to be stored on site so as not
      to interfere with other trades
    - all redundant underground services to be removed from
      ground, cap services at suitable termination locations.

                                                                                                                                                                                                                                                                                                       0         1m                     5m




                                                                                              Revision                                                                                                                                                     Proposed Residence Address              Client             Scale
This plan shall remain the sole property of Suncoast Building Design and must not be                                                                                                                                                                       1/10 Sunseeker Cl                       Noakes             1:100
given, lent, hired out or otherwise disposed of or copied without the written permission of   Rev A - 27.06.23 - Proposed Gazebo in leiu of Alfresco
Suncoast Building Design.
                                                                                                                                                                                                                                                           Noosaville
                                                                                                                                                                                                                                                                                                   Drawn              Page No.
Note: all dimensions/engineer details and relevant information to be checked and
confirmed by builder /client. Suncoast Building Design does not take any responsibility                                                                                                                                                                                                             MM/SB              4
after drawings have been checked and confirmed by builder/client or construction has                                                                                                          Suite 7 / 10 Grebe St, Peregian Beach   mob: 0401565629
commenced.                                                                                                                                                                                   [email protected]                           Job No.                      Date       Stage              Drawing
                                                                                                                                                                                             www.suncoastbuildingdesign.com.au       mob: 0491289102
                                                                                                                                                                                                                                                           20.141                       27.06.23   DA Approval        Demolition Plan

Used in these records

About this file

File size
12.6 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

RFI - Amended design plans.pdf · 12.6 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.