g®

 

6.90

EL/0.8

eo

/ ‘SWI300

5.39

7,89

es) TRANSFORMER

Open Channels drain to here

ILSW/450

 

   

ILSW/450

     
  

hom

6.23

      
     

Client

Stockwell Development Group Pty Ltd

 

 

Project

Noosa Civic, Noosaville

 

Detail and Level Survey of part
of Part of Lot 3 on SP246584

Original Lot 29 on MCH390

Parish of Tewantin

County of March

Local Authority : Noosa Shire

 

 

Horizontal Datum (MGA94)

 

 

Datum for Levels (AHD Derived)

56522
Located in Production Street
RL 7.30m
Contour Interval - 0.25m

 

 

_ Sheet Layout
So \

 

 

 

 

 

 

 

 

 

 

 

Mery ZY
Z
LEGEND

Bore Water Line — Wwa— Electricity Pole EP
Fence (internal) =§5 ——v—— Electricity Connection Box ECB
Fence (External) Parking Sign PS
Gas Main —G— Pole Mounted Transformer PMT
Overhead Power —v— Sewerage Manhole SMH
Sewerage Pipe —_s— Stormwater Manhole SWM
Stormwater Drain =—-SW— Telecom Connection Box TCB

Telecom Cable —_7— Telecom Manhole TMH
Underground Power ——UE — Fire Hydrant FH

Town Water —wW— Gully Trap GT
Tree Line oY V™ Water Meter WM
Kerb K Water Valve Ww
Channel Cc Floor Level FL
Crown of Road CR Invert Level Stormwater /LSW
Edge of Bitumen B Ground Level GL
Gas Valve GV Surface Level SL
Electricity Light Pole ELP Water Tap Wr
Electricity Manhole EMH Down Pipe DP.
Power Pole PP Street Sign SS
Traffic Sign TS Lip ZL
Telecom Pillar TCP Water Manhole WMH
Roof Level RL Invert Level Sewer ILS
Flag Pole FLG Elec Stay Pole SE
Under Slab Level USC Traffic Light 7L
Grease Trap GIR Traffic Light Camera TLC
Gutter Level GUT Surface Level Tiles SLT

 

Notes and Disclaimers -

Every endeavour has been made to identify and measure the accurate location
and depth of utility services however existing records obtained from the relevant
authorities may be incomplete or inaccurate. There may be no physical evidence
of the existence of a service and may be of nonconductive materials and therefore
not traceable. In this instance it was not practical to physically expose services for
visual identification and measurement. Services information compiled and shown
on this survey are subject to the limitations outlined above.

The positions and dimensions of property boundaries have been compiled from
Identification survey 1S274197.

 

Bennett & Francis Pty. Ltd.

Surveying, Cartography, Computing,
Mapping, Town Planning.
ACN. 053 307 172

100 Ipswich Road,
Woolloongabba Q 4102
Phone (07) 3239 5444
http://www.bfsurveys.com.au

 

 

 

 

 

1:200
0 2 4 8 l2 I6 20
METRES.
Drawn ~=SRH Date 07/06/2019
F.W. SRH Checked JPMW
FB. 18-01 Approved Date
JPMW 07/06/2019

 

 

PLAN REF. © 2019. All rights reserved.

034389 41 Bennett and Francis
. ABN 49 446 453 598

Rev.

 

 

 

 

V:\034389\ACADatal03438941.dwg Sheet2 of 6

 
Log in to download the original file

RFI - Appendix G SWMP by MPN Consulting.pdf · 5.3 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.