20200466 - GIA Plans Previously Reviewed by Glen Conforti.pdf
AC OVER
EF
TV 850
0 EF
140
BATH
AC OVER
400
ENS
0
140
0
BED 2 140
BED 1
MSB
400
D
S D
900
3W S S
ENTRY
VOID 3W
TO
GROUND
FLOOR
ELECTRICAL- FIRST FLOOR
1 1 : 50
ELECTRICAL LEGEND
ELECTRICAL SWITCH LOCATION - SINGLE POWER POINT GENERAL NOTES
- RECESSED LOW VOLTAGE CEILING LED DOWNLIGHT - DOUBLE POWER POINT - ALL LOW GPO'S 100MM OFF FLOOR
- ALL LIGHT SWITCHES 1000MM OFF FLOOR
- EXTERNAL GRADE SUITABLE, WALL MOUNTED LIGHT - ALLOW FOR REVERSE CYCLE SPLIT SYSTEM AIR
600 HIGH FROM FLOOR UNLESS NOTED OTHERWISE C6 - C6 DATA CABLE & POINT CONDITIONING, UNITS CONCEALED WITHING BULKHEADS AS
DETAILED, REFER TO REFLECTED CEILING PLANS FOR UNIT
- SURFACE MOUNTED LED WALL LIGHT LOCATIONS. ZONE 1- BED 1, ZONE 2- BED 2, ZONE 3- OFFICE
USB - USB CHARGER WITH DOUBLE POWER POINT COMBO (STANDARD WALL MOUNTED SPLIT SYSTEM UNIT), ZONE 4-
- LOW VOLTAGE ADJUSTABLE ANGLE GARDEN LIGHT BED 3, ZONE 5- ENSUITE, ZONE 6- LIVING/ DINING. EXTERNAL
ON SPIKE WITH AUTOMATIC TIMER AND SUNDOWN CONDENSOR UNITS LOCATED UNDER ENSUITE TO
SENSOR TV - TELEVISION POINT CABLE AND FREE TO AIR UNDERCROFT
- ELECTRICIAN TO GROUP WHERE APPROPRIATE LED
- RECESSED LOW VOLTAGE FLOOR LIGHT FITTINGS ONTO REQUIRED NUMBER OF DRIVERS AND TO
T
- TELEPHONE POINT ALLOW FOR POSSIBLE ADDITINAL FUTURE LIGHT FITTINGS
- RECESSED CONTINUOUS LENGTH STRIP LED LOW - BACK TO BASE INTRUDER ALARM SYSTEM WITH PET
VOLTAGE LIGHT IN RECESSED POWDERCOATED WP - WATERPROOF FIXTURE FRIENDLY INTERNAL MOTION SENSORS, AUDIBLE ALARM AND
ALUMINIUM CHANNEL WITH DIFFUSER EXTERNAL STROBE LIGHT
EF - EXHAUST FAN - 3 PHASE MAINS POWER TO BE PROVIDED FROM ROAD
- CEILING PENDANT LIGHT
MSB - SWITCH BOARD AIR CONDITIONING NOTES
S - SMOKE DETECTOR HARD WIRED AND
INTERCONNECTED TO AUSTRALIAN STANDARDS AND - A/C REGISTERS AND POSITIONS ARE INDICATIVE ONLY -
QUEENSLAND REQUIREMENTS - INTERCOM MECHANICAL CONTRACTOR TO LIASE WITH BUILDER / CLIENT
TO DETERMINE FINAL POSITION AND EXTENT OF GRILLES AND
- LOW VOLTAGE LED ADJUSTABLE ANGLE WALL TWIN A/C UNITS REQUIRED.
SPOT LIGHT - BUILDER TO ALLOW FOR THE CONSTRUCTION AND FINISHING
- 1500 DIA. CEILING FAN OFF OF REQUIRED BULKHEADS TO HOUSE A/C UNITS.
- LOW VOLTAGE SURFACE MOUNTED CEILING LED - FINAL EXTENT OF BUKHEADS TO BE DETERMINED ONSITE
DIRECTIONAL LIGHT 1500 WITH A/C CONTRACTOR / BUILDER AND CLIENT.
D - ADJUSTMENTS TO JOINERY UNITS DUE TO A/C BULKHEADS
- LIGHT DIMMER COMPATIBLE WITH LED LIGHTS AND ACCESS PANELS MAYBE REQUIRED AFTER FINAL
EXTENT DETERMINED.
no. description date
HINCKFUSS RESIDENCE ELECTRICAL PLAN date 21.10.2020
WD 7.01
e. [email protected]
drawn by Author
LITTLE COVE COURT- APARTMENT 8, 2 PANDANUS STREET, NOOSA HEADS PRELIMINARY- WORKING DRAWINGS p. 0447 494 202
checked by Checker scale @ a3 As indicated
a. p.o.box 365, noosaville, qld 4566
[OCR of page images]
AC OVER
— ee ©
Do \
7 \ BATH A é
COVER / a
a
4¥ 7 ~f ENS O71 /
R ) y
an \
\ QO Errol /
~~ 7 / Q 40 / \
~
/ ~ / ! ! \ BED 1
| LZ \
/ a Dy |
/ «<q !
Elo
/ ‘0 > Lo
Jo ~— —|P- 7
| 7
. ~ ENTRY
| r > We Se
“
TO | | <
GROUND x DN | L-
FLOOR [ p07
X ELECTRICAL SWITCH LOCATION WY - SINGLE POWER POINT GENERAL NOTES
O - RECESSED LOW VOLTAGE CEILING LED DOWNLIGHT y - DOUBLE POWER POINT - ALL LOW GPO'S 100MM OFF FLOOR
- ALL LIGHT SWITCHES 1000MM OFF FLOOR
- EXTERNAL GRADE SUITABLE, WALL MOUNTED LIGHT - ALLOW FOR REVERSE CYCLE SPLIT SYSTEM AIR
_ 600 HIGH FROM FLOOR UNLESS NOTED OTHERWISE cI - C6 DATA CABLE & POINT CONDITIONING, UNITS CONCEALED WITHING BULKHEADS AS
DETAILED, REFER TO REFLECTED CEILING PLANS FOR UNIT
Oo - SURFACE MOUNTED LED WALL LIGHT LOCATIONS. ZONE 1- BED 1, ZONE 2- BED 2, ZONE 3- OFFICE
UsB] - USB CHARGER WITH DOUBLE POWER POINT COMBO (STANDARD WALL MOUNTED SPLIT SYSTEM UNIT), ZONE 4-
oO - LOW VOLTAGE ADJUSTABLE ANGLE GARDEN LIGHT BED 3, ZONE 5- ENSUITE, ZONE 6- LIVING/ DINING. EXTERNAL
L ON SPIKE WITH AUTOMATIC TIMER AND SUNDOWN CONDENSOR UNITS LOCATED UNDER ENSUITE TO
SENSOR TV] - TELEVISION POINT CABLE AND FREE TO AIR UNDERCROFT
- ELECTRICIAN TO GROUP WHERE APPROPRIATE LED.
© - RECESSED LOW VOLTAGE FLOOR LIGHT T FITTINGS ONTO REQUIRED NUMBER OF DRIVERS AND TO
vW- TELEPHONE POINT ALLOW FOR POSSIBLE ADDITINAL FUTURE LIGHT FITTINGS
mcmcm - RECESSED CONTINUOUS LENGTH STRIP LED LOW - BACK TO BASE INTRUDER ALARM SYSTEM WITH PET
VOLTAGE LIGHT IN RECESSED POWDERCOATED WP. - WATERPROOF FIXTURE FRIENDLY INTERNAL MOTION SENSORS, AUDIBLE ALARM AND
ALUMINIUM CHANNEL WITH DIFFUSER EXTERNAL STROBE LIGHT
- EXHAUST FAN - 3 PHASE MAINS POWER TO BE PROVIDED FROM ROAD
<> - CEILING PENDANT LIGHT
- SWITCH BOARD AIR CONDITIONING NOTES
- SMOKE DETECTOR HARD WIRED AND
INTERCONNECTED TO AUSTRALIAN STANDARDS AND - A/C REGISTERS AND POSITIONS ARE INDICATIVE ONLY -
QUEENSLAND REQUIREMENTS - INTERCOM MECHANICAL CONTRACTOR TO LIASE WITH BUILDER / CLIENT
TO DETERMINE FINAL POSITION AND EXTENT OF GRILLES AND
Qp - LOW VOLTAGE LED ADJUSTABLE ANGLE WALL TWIN A/C UNITS REQUIRED.
SPOT LIGHT - BUILDER TO ALLOW FOR THE CONSTRUCTION AND FINISHING
- 1500 DIA. CEILING FAN OFF OF REQUIRED BULKHEADS TO HOUSE A/C UNITS.
Q- LOW VOLTAGE SURFACE MOUNTED CEILING LED - FINAL EXTENT OF BUKHEADS TO BE DETERMINED ONSITE
DIRECTIONAL LIGHT WITH A/C CONTRACTOR / BUILDER AND CLIENT.
D - ADJUSTMENTS TO JOINERY UNITS DUE TO A/C BULKHEADS
+ - LIGHT DIMMER COMPATIBLE WITH LED LIGHTS AND ACCESS PANELS MAYBE REQUIRED AFTER FINAL
EXTENT DETERMINED. no. | description |date
FRANKMIACCHIA date 21.10.2020
HINCKFUSS RESIDENCE ELECTRICAL PLAN TUT WD 7.01
LITTLE COVE COURT- APARTMENT 8, 2 PANDANUS STREET, NOOSA HEADS| PRELIMINARY- WORKING DRAWIN poser age 202 om srewney “ner
URT- ’ U ’ - WO G GS e pi pon 36% noosavile, qld 4566 checked by Checker |scale @ a3 As indicated