                 G                                                   H                     J

                                                                                                                                                                     BOUNDARIES AND SETBACKS
                                                                                                                                                                     Boundary distances and setbacks to existing
                                                                                                                                                                     buildings and extension are based on the previous
                                                                                                                                   Living Plate
                                                                                                                                                                     plans. Prior to construction the position of existing
                                                                                                                                         26170                       building and proposed extension shall be
                                                                                                      Form new parapet over                                          confirmed on site.
                                                                                                      existing wall as required
                      Existing roof framing to remain.
                                                                                                      to builders specification.                                     "AS CONSTRUCTED" DRAWINGS
                                                                                                      Existing corner window                                         Existing residence drawings have been prepared to
                                                                                                      hood to remain.                                                reflect the "As Constructed" condition of the building.
                                                                                                                                                                     The author was not engaged to supply accurate survey
                                                                                                                                                                     of the buildings or architectural elements of the
                                                                                                                                                                     residence, nor assess the structural design of footings,
                                                                                                                                                                     framing or bracing.
                                                                                                                                                                     These drawings have been prepared from visible
                                                                                                                                                                     elements, some site measurements and the previous
                                                                                                                                                                     house plans. Not all architectural elements and
                                                                                                                                                                     structural elements were visible or accessible for
                                                                                                                                                                     measurement. Fixings and member sizes are "as
                                                                                                                                                                     constructed"

                                                                                                                                                                     NOTE - CONTOUR SURVEY
         2570




                                                                                                                                                                     Site levels and other existing features and information
                                                                                                                                                                     have been obtained from original house plan survey
                                                                                     Existing corner fixed glass to remain.                                          done to arbitary datum and then converted to match
                                                                                                                                                                     contours on council web site. (No survey has been
                                                                                                                                                                     undertaken on site to establish the position or levels)

                                                                                     Existing sloping wall to be
                                                                                     removed & make good.

                                      Living                                   700

                                                                                                                         Planter tubs with built in
                                                                         220         480                                 drainage along front of
                                                                                                                         Living to builders spec.
                      Raise floor 300mm
                      to match Dining to




                                                                                                                   150
                      builders specification.
                                                                                                                                   Living Floor
                                                                                                                                         23600
         300




                                                                                                                   300
                                                                         700




                                                                                                                           Garage Entry Plate
                                                                                                                                       23300




                                                                                                                   250
                      Existing HJ 245 88 floor joists strengthened
                      with plywood for contilever to remain.                                                  Conceal steel beams with
                                                                                                              FC clad over timber frame.
                      Existing HJ 245 88 floor joists to remain.

                      Conceal steel beams with                                                                New Steel I beam to support
                      FC clad over timber frame.                                                              planter boxes to engineers detail.
                      Existing 310UB45 to remain.


                                      Carport
                                                                                                                                                                                                                                  NOOSA COUNCIL
                                      Section 4                                                                                                                                                                                   APPROVED PLAN
                                      1 : 20                                                                                                                                                                                 132003.220763.1 12 MAR2024




                                                                                                                                                                                      plans2go
Proposed Residence                                                                                                                                    PETER COOKE                               concept to                                   Postal Address :
                                                Job No       2366                                   Design               PC                                                                                                                    28 Kawanna St
                                                             10                                                                                       BUILDING DESIGNER
Kerrie McCartney                                Sht. no                                                                                               QBSA Lic : 81626                                                                         Mudjimba 4564
                                                Date         27-11-23                               Rev    C                                                                                                                                  Email Address :
2-512 David Low Way                                                                                                                                                                                                                [email protected]
                                                Drawn        PC                                                                                       Plans2go Pty Ltd
Castaways Beach                                                                                     Status Finishes                                   0428 842316                         building application                     www.plans2go.blogspot.com

Used in these records

About this file

File size
3.7 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Approved Plan - 132003 220763.2. (As Published)pdf.pdf · 3.7 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.