Project Job No. 91485

 

WALL TYPE "A"

f7—— Slab Fabric

500 t-> 500

 

Slab Fabric

 

 

 

 

lab

 

 

dl

N12 @ 400mm Ctrs.

Longitudinal reinforcement N12 @ 400
a except on top of clean-out blocks

 

 

&

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  

 

 

 

 

 

 

 

 

 

 

 

Uo LI
L ol Longitudinal reinforcement N12 @ 400
Lol ke ——-ssmm Cover LVI except on top of clean-out blocks
_— Lap bars min.450mm. ls. 55mm Cover
H 5
. ory]
Clean-out blocks K— N12 @ 400mm with 5 cover (V-bars) N12 @ 400mm Ctrs.
Lal | N12 @ 400mm with 55 top cover (X-bars) TS
vd Lap bars min.600mm
CL ‘ J 200 i
4 7
0 U : N12 @ 400mm with 55 cover (V-bars)
N12. @ 400mm Cts. _-7 Hiean-out blocks
300, | | "
le | | N12 @ 400mm with 55 top cover (X-bars)
I! BO. jo wv
i< al dds CL en = - | Ros
fp hy
450)
WALLS 0.8m,1.0m or 1.2m HIGH |
Mw
350
es B
1

 

WALLS OVER 1.2m and up to 1.8m HIGH

7 Slab Fabric

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Clean-

 

WALL TYPE "A"
Suspended Siab Section

Suspended Slab as per details

by STA Consulting Engineers
r Cy

Job No.91485
Longitudinal reinforcement N12's @ 400

 

N12 @ 400mm Ctrs.

H Lap bars min.450mm

 

4

 

1

 

 

blocks
N

 

{LJ
I} —— K-bars with 55 cover

  

 

 

i
Ne 7 V-bars with 55 cover
vy ele

 

 

 

 

 

 

 

X-bars with 55 cover |

Kay >I |
ee

WALLS OVER 1.8m and up to 3.4m HIGH

 

 

Base Sizes for Wall Type *

\ 7 A

Slab as per
—— Foundation Cross Section

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Base Width Height of block Height of block] Height of block X&-bars
=A "BT 150 Series 200 Series 300 Series & K-bars
Vi Lor ral reinforcement N12's @ 400 V-bars.
800 800 800 N12 -
is N12 @ 400mm Cus. 1000 900 1000 N12 ;
H [I Lap bars min.450mm 1200 1000 1200 N12 :
it 1400 1100 1400 N12 :
[. ] 1600 1200 1600 N12 :
LT Il jement NY12's @ 400 1800 1400 1800 N12 -
i except on top of clean-out blocks
MI oreo 2000 1600 1400 600 N12 N12 -
Clean-out blocks | sh K-bars with 55 cover nes ork 2200 4800 4400 800 Ni2 M
Hele} emer | 2400 “2000 1600 800 N16 N12
\ :
VOLT . a x 2600 2100 1600 1000 N16 N16
300 —
Ba \ 7 t 2800 2200 1800 4000 N16 N16
iy [ee separa Lan 56 cover 3000 2400 2000 4000 N16 @ 200) N16 @ 200
Kas > 3200 2600 2000 1200 N16 @ 200] N16 @ 200
B 3400 2800 - 2000 4200 N16 @ 200] N16 @ 200)
WALLS OVER 1.8m and up to 3.4m HIGH
ALL BARS ARE TO BE AT 400 Ctrs. UNLESS OTHERWISE STATED
Design Company . . .
SOILTEST AUSTRALIA ENGINEERING SERVICES PTY LTD STA Builder Builders Client
Suite 1, 848 Boundary Ra, Richlands, Qld, 4077 Bob & Sheryl Hedges NIA

ACN 109 233 123 Fax (07) 33759299 Ph.1300 731523 ALETANCE

PO Box 6354, St Lucia Qld 4067

 

Client Order Number: N/A

 

 

 

Used in these records

About this file

File size
2.8 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Original Application Part 17 - Structural Plans [As Published].pdf · 2.8 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.