Council archive · source document
Planning Report & Code Assessment · MCU15/0014
Attached to the e-mail MCU15/0014 Development Application.
Specific Outcomes Probable solutions Proposal - 50% on the ground floor and 30% for the upper storey(s), or 40% for all storeys for a building of 2 or more storeys; c) for other classes with the Detached Housing Zone, does not exceed—40%; d) for the Semi-Attached Housing Zone does not exceed 40%; e) for the Attached Housing Zone does not exceed 40%; f) for the Visitor Mixed Use Zone does not exceed 40%; or g) for the Shire Business Centre Zone in Precincts E1, E2, E6 and E7 does not exceed 50%. O12 For the Semi-Attached Housing Not applicable Zone buildings do not exceed a plot ratio of 0.45:1 O13 For the Attached Housing Zone the Not applicable maximum gross floor area is equivalent to the maximum allowable population in persons multiplied by 40m2. O14 For the Visitor Mixed Use Zone, the Complies maximum gross floor area equals the The proposed gross floor area does not allowable population in persons exceed the maximum allowable. multiplied by 40m2, provided that the gross floor area does not exceed 13,600m2. O15 For the Business Centre Zone, Not applicable outside of the Mary Street/Thomas Street Precinct the maximum plot ratio is — a) 0.8:1 for site areas up to and including 2,000m2; plus b) 0.3:1 for the balance portion of the site area in excess of 2000m2. O16 Within the Shire Business Centre Not applicable Zone, the maximum plot ratio for development within the following precincts is — a) Precincts B1 and B2 combined- 0.5:1; b) Precinct B3- 0.8; c) Precinct E1- 0.6; d) Precinct E2- 0.6; e) Precinct E3- 0.6; f) Precinct E4- 0.6; g) Precinct E5- 0.6 h) Precinct E6- 0.6; i) Precinct E7- 0.6; j) Precinct RES- 0.6; and k) Precinct REC/MU- 0.1. Flooding and drainage O17 Buildings and other works are S17.1 For new buildings or structures Complies designed and sited to— or additions more than 50m2 gross floor Development will comply with the a) provide flood free access to premises area to an existing building or structure, minimum floor level requirements. Refer and flood free habitable areas; floor levels for habitable rooms are not to the accompanying Architectural Plans. b) allow only minor, short term and less than the specified minimum floor infrequent flooding of non-habitable levels areas; AND c) ensure drainage does not adversely S17.2 Where Council infrastructure is Complies impact upon other premises; and available— Drainage will flow to existing drainage d) ensure filling or excavation does not any drainage (including buildings and infrastructure. adversely impact upon other premises yards) flows to that infrastructure; and by— the infrastructure has the capacity to i) causing ponding on the site or accept any additional loading; nearby land; AND ii) increasing flooding, which S17.3 for Residential Uses - Complies – Alternative solution adversely affects the safety or use of where slab on ground construction is Refer section 7.5.1 of planning report.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Planning Report & Code Assessment.pdfRelated documentApplication case desk ↗
About this file
- File size
- 1.2 MB (small file)
- File type
No other editions are linked here.