Skip to the record
For the highest quality transcripts.

Council archive · source document

Development Assessment Report · MCU26/0067

of 57

Text shows just the words. Original shows the document exactly as it was published.

Check the original when the exact wording matters.

paving material or fencing are examples of delineating a
waste storage area. The locking of the area is not
preferred and should be avoided.

Water management

PO6                                                        AO6                                                     Complies
Waste storage areas are designed to contain and            The waste storage area is constructed of                The site is fully developed and provided with
appropriately dispose of leakage from bins and             impermeable and durable surfaces and:                   waste storage facilities.
wastewater from bin washing.                               (a) is bunded and graded so that washwater and
                                                                bin leakage are drained to the sewer or an on-
                                                                site effluent disposal system via a gully within
                                                                the storage area;
                                                           (b) has a bund wall with a maximum height of 100
                                                                millimetres;
                                                           (c) is serviced by a conveniently located hosecock
                                                                and backflow prevention device, and
                                                                connected to a water supply; and
                                                           (d) is roofed or otherwise covered if the storage
                                                                area is—
                                                                (i)   more than 1m2; or
                                                                (ii) storing wet waste; or
                                                                (iii) storing other waste with a high potential
                                                                      to cause pollution if washed or leaked
                                                                      from the bins, including waste oil or
                                                                      putrescibles.

Safety and protection of infrastructure when demolishing or removing buildings
PO7                                                        AO7.1                                                   Not Applicable
Demolition, removal, relocation or associated works        Infrastructure including reticulated water, sewerage,   The development does not involve demolishing or
do not result in:                                          stormwater, and electricity are protected from          removing buildings.
(a) 'live' or 'active' infrastructure that may present     damage and made safe to the standard required by
     risk to people using the site or surrounding          the regulatory authority.
     areas; or
(b) damage to infrastructure or other works.               AO7.2
                                                           Infrastructure is disconnected, capped or sealed
Editor's note— An approval will be required from           including:
Council's Building and Plumbing Services for               (a) electricity meters are removed and electrical
decommissioning plumbing apparatus including:                    wires disconnected;
(a)   sanitary drains or reticulated water supply; and
(b)   septic tanks, holding tanks or on-site treatment
                                                           (b) telephone lines are disconnected; and
      systems.                                             (c) data cables are disconnected and removed.

                                                           AO7.3

Used in these records

About this file

File size
3.6 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Development Assessment Report.pdf · 3.6 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.