Council archive · source document
Information Request MCU26 0001 · MCU26/0001
c. avoid box profiles/parapets; and
d. do not create opportunities for overlooking the private open space or internal spaces
of neighbourhood properties.
Information Required
5. Revise plans and suitably demonstrate compliance with Performance Outcome PO17
of the High Density Residential Zone Code. This may include but not be limited to:
5.1. Reduction to the size of the rooftop terrace so that the usable outdoor area is
located toward the centre of the roof, away from the site boundaries, thereby
limiting potential overlooking and visual intrusion.
5.2. Providing a view line assessment (plan and section-based diagrams) illustrating
sightlines between the rooftop terrace and the adjoining residential properties’
private open space, to assist in determining the extent of overlooking and whether
additional screening or design amendments are required.
Issue – Stormwater
The proposed drainage design includes a new stormwater pit (Structure 2/1) abutting the new
crossover, connecting into an existing stormwater pit (Structure 1/1). Structure 1/1 appears to
be in poor condition (Figure 1). Council has concerns the new stormwater pit (Structure 2/1)
may be damaged by vehicles accessing the development (Figure 2).
Figure 1 - Existing Pit (Structure 1/1) Figure 2 - Crossover & Structure 2/1
Information Required
6. Provide a revised drainage design in accordance with PO3 & PO4 of the Water Quality
and Drainage Code including;
a. Replacement of structure 1/1 in accordance with the Noosa Plan Planning Scheme
Policy 6 Engineering Design Standards
b. Removal or relocation of structure 2/1 to provide a minimum 1m of separation to
the driveway crossover in accordance with Standard Drawing RS-049
Issue – Existing Infrastructure
An existing stormwater pipe traverses the property connecting to the upstream drainage
network.
The Basement Architectural Plan (DA2.01 Rev B) prepared by Blackwood shows the pipe
within a 0.79m wide corridor measured from the basement to the property boundary.
Earthworks sections (C102 Rev A) prepared by Recor do not show the service. It’s unclear if
the service has been accurately located and appropriately protected.
Page 4 of 6
Document Set ID: 24510032
Version: 3, Version Date: 02/03/2026
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Information Request MCU26 0001.pdfRelated documentApplication case desk ↗
About this file
- File size
- 348 KB (small file)
- File type
No other editions are linked here.