Original source · versioned page text
Bushfire Report
Ecological Natural Area Management 1 Executive Summary A house to be established at 411 Black Pinch Rd, Cootharaba, Queensland in the Noosa Council jurisdiction is mapped in a Potential Bushfire Impact Buffer area on The Noosa Plan Bushfire Overlay and Queensland Potential Bushfire Intensity mapping. Therefore, the house is deemed to potentially be in a Bushfire Prone Area and an assessment of the bushfire risk to the building and a bushfire risk management plan is required. Assessment of Bushfire Prone Area As the house is mapped in a Potential Bushfire Impact Buffer area on The Noosa Plan Bushfire Overlay and Queensland Potential Bushfire Intensity mapping: • The house is deemed to be in a Bushfire Prone Area. As the the house is in a Bushfire Prone Area, an assessment of the Bushfire Attack Level using Australian Standard AS3959 Construction of buildings in bushfire prone areas is required to be conducted as specified by the Queensland Building Act and the bushfire requirements of the National Construction Code. Assessment of the Bushfire Attack Level The Bushfire Attack Level (BAL) for the house using Method 2 of Australian Standard AS3959 Construction of buildings in bushfire prone areas was assessed as: • BAL 12.5 for all building elevations. Assessment of vegetation clearing • No clearing of vegetation with conservation significance is required for bushfire risk mitigation in this plan Recommendations Recommendations for the Noosa Plan Bushfire Overlay Code As the house location is in a Potential bushfire Impact Buffer area, it is recommended that: • The house is sited in a low hazard area in the lot and achieves a setback of 10 metres from any retained vegetation. As the house location is in a Potential bushfire Impact Buffer area and a reliable reticulated water supply is not available, It is recommended that: • The premises to have a minimum water supply capacity of 5,000 litres dedicated for fire fighting purposes which is sourced from a separate tank, a reserve section in the bottom part of the main water supply tank, a swimming pool installed immediately upon construction or a permanent dam. Recommendations for Australian Standard AS3959 Australian Standard AS3959 Construction of buildings in bushfire-prone areas specifies Deemed to Satisfy bushfire resistant methodologies based on the assessed Bushfire Attack Level. It is recommended that: • The building solution for all building elevations to address the Deemed to Satisfy requirements of Sections 3 and 5 of Australian Standard AS3959-2018 Construction of buildings in bushfire-prone areas. Bushfire Risk Assessment and Management Plan for a house at 411 Black Pinch Rd, Cootharaba December 2021 5
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.