Bushfire Hazard Assess Lot 9 on RP225312 — 100 Cooyar Street, Noosa Heads ment & Management Plan v2 NCES REF: J000542 APPENDIX 5 — RADIANT HEAT BARRIER CALCULATION Fire Danger Index 48 Vegetation classification Woodland Understorey fuel load 16.8 t/ha Total fuel load 24.3 t/ha Vegetation height nla Effective slope 1° Site slope 1° Distance to vegetation 30.6 m Flame width 100 m Windspeed va Heat of combustion 18,600 ki/kg Flame temperature 1,200 K Actual barrier height 2.5m Rate of spread Flame length Flame angle Panel height Elevation of receiver Effective barrier height Fire intensity Transmissivity Viewfactor Radiant heat flux Viewfactor of barrier Adjusted viewfactor 1.03 km/h 9.65 m 80° 3.5m 4.22m 2.5m 13,017 kW/m O.8139999999999999 0.1474 13.41 kW/m? 0.0373 © 2023 46