Original source · versioned page text
Approved Reference Documents - 132001.210127.3
Very large file (23.3 MB): the original may take a few minutes to open or download. The page text below is quick to read.
Fire Safety Strategy – Bushfire Fire Spread Prevention 100 Cooyar Street, Noosa Heads QLD 4567 ▪ The Fire Engineering Assessment contained within this document is specific to this project. The findings and outcomes of this report shall not be used outside the scope of this project. ▪ The analysis is limited to the assessment of single / accidental fires as intended by the BCA. The fire scenarios investigated within this document may be representative of intentional fires caused by an opportunistic arsonist; however multiple fires, severe acts of malice intent, terrorism, sabotage, or by wilful interference with fire and life safety systems are considered outside the scope of this assessment. 1.5 Assumptions The primary assumptions used to prepare this Fire Safety Strategy Report are outlined below. Assumptions are based on practices nominated in the International Fire Engineering Guidelines and incorporate practical simplifications to maintain a simple analysis that is representative of a real fire and life safety situation. Assumptions are: ▪ Only one fire will occur at a time. In the event of a fire within the building. ▪ All essential services, equipment services and strategies will be maintained to the operational capacity to which they were designed and will correctly function during a fire situation. ▪ Prevention of arson, sabotage, and acts of malice are considered to be addressed by security systems and management procedures for the facility. ▪ Occupants will become aware of the fire through fire cues from the alarm system, respond to the cue, cope with the cue and attempt to avoid the fire, as intended by the BCA for safe evacuation. ▪ All other components of the building not addressed within this document will be installed to the requirements of the Deemed-to-Satisfy provisions of the Building Code of Australia applicable at the time of design. 1.6 Building Characteristics The project involves the development of the existing RACF located in Noosa the location of which is depicted in Figure 1. P a g e 7 | 18 Pro Project Number: WBFE965-001-2023 Date: 22/03/2023
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.