E D C B A E D C B A
3700 12360 9890 3258 3700 12360 9890 3258
RESHAPED GROUND LINE RESHAPED GROUND LINE
EXISTING RETAINING WALL EXISTING RETAINING WALL
MRS
EG EG
PITCHING POINT PITCHING POINT
RL 13.400 RL 13.400 DP DP DP DP RB1
RB1 RB1 SCR2 SCR2
SC RB1 RB1 RB1
3000
3000
FLOOR LEVEL FLOOR LEVEL
RL 10.400 RL 10.400
01 NORTH ELEVATION 04 SOUTH ELEVATION
- SCALE 1:100 - DRIVEWAY AISLE SCALE 1:100
A B C D E 04 03 02 01
3258 9890 12360 3700 5680 5620 5680
RESHAPED GROUND LINE
EXISTING RETAINING WALL
RESHAPED GROUND LINE
OUTLINE OF EXISTING
RETAINING WALL SHOWN
DASHED
5° FALL 5° FALL
EC
PITCHING POINT PITCHING POINT EG EG
RL 13.400 RL 13.400 SC
SCR2 SCR2 RB1 RB1 RB1
COURTYARD
RB2 RB1 RB1
SCR1
3000
3000
MULCH
GREEN WASTE DRIVEWAY STORE &
RB1 STORE AISLE CARPORT
FLOOR LEVEL FLOOR LEVEL DP DP
RL 10.400 RL 10.400
02 SOUTH ELEVATION 05 EAST ELEVATION
- SCALE 1:100 - SCALE 1:100
A B C D E 01 02 03 04
3258 9890 12360 3700 5680 5620 5680
ROOF FRAMING TO
RESHAPED GROUND LINE STRUCTURAL ENGINEERS
RESHAPED GROUND LINE DETAILS & SELECTED METAL
EXISTING RETAINING WALL ROOFING OVER BATTENS
5° FALL EXISTING 5° FALL
RETAINING WALL EC
MC
PITCHING POINT PITCHING POINT EG EG
EG EG
RL 13.400 RB1 RB1 RB1 RB1 RL 13.400
SC SC
RB2 RB1
CARPORT MULCH SCR1
3000
3000
STORE RB2 RB1 DRIVEWAY
RB1 RB1
AISLE
COURTYARD
DP DP DP DP DP DP
FLOOR LEVEL FLOOR LEVEL
RL 10.400 RL 10.400
03 NORTH ELEVATION 06 WEST ELEVATION
- DRIVEWAY AISLE SCALE 1:100 - SCALE 1:100
EXTERNAL FINISHES LEGEND
CODE ITEM DESCRIPTION
MRS METAL ROOF SHEET LYSAGHT 0.48bmt KLIP-LOK PROFILE COLORBOND - WOODLAND GREY
EG METAL EAVES GUTTER FOLDED HALF ROUND METAL GUTTER WITH COLORBOND - WOODLAND GREY
EXPOSED UNDERSIDE SUPPORT BRACKETS
RB1 RENDERED BLOCKWORK BLOCKWORK WALLS WITH APPLIED SMOOTH COLORBOND - WOODLAND GREY
SET RENDER FINISH
RB2 RENDERED BLOCKWORK BLOCKWORK WALLS WITH APPLIED SMOOTH COLORBOND - FLINT GREY
SET RENDER FINISH
DRAFT
DP DOWNPIPE UPVC DOWNPIPE WITH PAINT FINISH - REFER TO MATCH WALL COLOUR ADJACENT
HYDRUALIC ENGINEERS SIZE REQUIREMENT
SCR1 SCREEN VERTICAL POWDERCOATED ALUMINIUM SCREEN DULUX POWDERCOAT - WOODLAND GREY
SATIN
SCR2 SCREEN HORIZONTAL POWDERCOATED ALUMINIUM DULUX POWDERCOAT - WOODLAND GREY
SCREEN SATIN
SC STEEL COLUMN NOM. 90 x 90mm STEEL COLUMN, PAINT FINISH DULUX MONUMENT SATIN 2729067S
NOTE:
ALL ALUMINIUM FRAMED WINDOWS & DOORS TO BE DULUX POWDERCOATS MONUMENT BUILDING APPROVAL
NOT FOR CONSTRUCTION
CHECKED : ………………………………..………..
notes : issue revision log by date issue revision log by date project:
north date: APR 22
1. The designs, drawings and specification are
A FOR APPROVAL TT 19-05-22
PROPOSED MAINTENANCE SHED,
copyright and always remain the property of drawn: TT
Blackburne Jackson Design Pty Ltd. NOOSA SPRINGS
A R C HIT E C T UR E | L A NDS C A P E | INT E R IO R | P ROJECT MA NA G E ME NT checked: LR
2. Before commencing construction: client:
- Verify all dimensions and levels. scale @ A1 : 1:100
- Verify location and levels of all services on site. 37 Aerodrome Rd Maroochydore Qld ALTUM CONSTRUCTIONS scale @ A3 : 1:200
- Verify that floor levels and finished levels will title:
MAINTENANCE SHED -
enable connection to services. P.O. Box 154 Cotton Tree QLD 4558 phone 07 5443 3200 project no. sheet: A1
5753_A04-01_A
3. Do not scale this drawing. email [email protected] fax 07 5443 4030
When in doubt refer to Architects. ELEVATIONS
5753-22-Maintenance Shed.pln printed: Wednesday, 1 June 2022 5:02 pm
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 1 page
Page 2
A B C D E
3258 9890 12360 3700
RESHAPED GROUND LINE
SELECTED METAL ROOF FRAMING TO EXISTING RETAINING WALL
ROOFING OVER STRUCTURAL
BATTENS ENGINEERS DETAILS
PITCHING POINT
RL 13.400
CAR WASH GREEN
BAY MANAGER'S WASTE
RESIDENCE
3000
STORE
DINING LIVING BEDROOM
FLOOR LEVEL
RL 10.400
SLAB AND FOOTINGS TO
STRUCTURAL
ENGINEERS DETAILS
A SECTION
- SCALE 1:100
E D C B A
3700 12360 9890 3258
RESHAPED GROUND LINE
EXISTING RETAINING WALL SELECTED METAL ROOF FRAMING TO
ROOFING OVER STRUCTURAL
BATTENS ENGINEERS DETAILS
PITCHING POINT
RL 13.400
SC SC
MULCH CARPORT MAINTENANCE
3000
STORE VEHICLE PARKING
FLOOR LEVEL
RL 10.400
SLAB AND FOOTINGS TO
STRUCTURAL
ENGINEERS DETAILS
B SECTION
- SCALE 1:100
04 03 02 01
5680 5620 5680
ROOF FRAMING TO
STRUCTURAL ENGINEERS RESHAPED GROUND LINE
DETAILS & SELECTED METAL
ROOFING OVER BATTENS
EXISTING RETAINING WALL
5° FALL 5° FALL
PITCHING POINT EG EG
RL 13.400
MANAGER'S DRIVEWAY MAINTENANCE
RESIDENCE VEHICLE
2900
LDY AISLE
COURTYARD
PARKING
KITCHEN
DP DP
FLOOR LEVEL
RL 10.500
SLAB AND FOOTINGS TO
STRUCTURAL
ENGINEERS DETAILS
DRAFT
C SECTION
- SCALE 1:100
BUILDING APPROVAL
NOT FOR CONSTRUCTION
CHECKED : ………………………………..………..
notes : issue revision log by date issue revision log by date project:
north date: APR 22
1. The designs, drawings and specification are
A FOR APPROVAL TT 19-05-22
PROPOSED MAINTENANCE SHED,
copyright and always remain the property of drawn: TT
Blackburne Jackson Design Pty Ltd. NOOSA SPRINGS
A R C HIT E C T UR E | L A NDS C A P E | INT E R IO R | P ROJECT MA NA G E ME NT checked: LR
2. Before commencing construction: client:
- Verify all dimensions and levels. scale @ A1 : 1:100
- Verify location and levels of all services on site. 37 Aerodrome Rd Maroochydore Qld ALTUM CONSTRUCTIONS scale @ A3 : 1:200
- Verify that floor levels and finished levels will title:
MAINTENANCE SHED -
enable connection to services. P.O. Box 154 Cotton Tree QLD 4558 phone 07 5443 3200 project no. sheet: A1
5753_A05-01_A
3. Do not scale this drawing. email [email protected] fax 07 5443 4030
When in doubt refer to Architects. SECTIONS
5753-22-Maintenance Shed.pln printed: Wednesday, 1 June 2022 5:03 pm
Used in these records
Plans - GIA.pdfRelated documentApplication case desk ↗
About this file
- File size
- 980 KB (small file)
- File type
No other editions are linked here.