Council archive · source document
Development Application - Part 2 of 2 - Plans · OPW12/0093
Plans and drawings: the text below has words only, no drawings.
-
Deve!or)ment Counter
Illiiliiilimj (i
80480580 j
Tewantin ~
THIS IS THE NEXT PART OF A
MULTIPLE PART RECORD
Part &Of ~
t5 6Z311~~,,J2’’’\I’’’’
,I)~\ IIC?,Y.’,.-.-.~
II
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 2 pages
Page 2
oPt<)!d.; OD90.
-"
GENERAL NOTES
1. All WORK IS TO COMPLY WITH THE QUEENSLAND PLUMBING &: DRAINAGE ACT
2002 ANO LOCAL AUTHORITY REQUIREMENTS.
2. THESE DRAWINGS ARE DIAGRAMMATIC ONLY. USE DIMENSIONED BUILDING
CONSTRUCTION PLANS FOR ANY SET OUT REQUIREMENTS.
3. OBTAIN APPROVAILS FROM All AUTHORITIES HAVING JURISDICTION AND PAY
All FEES DUE.
4. THE CONTRACTOR IS TO VISIT THE SITE TO BE FULLY AWARE OF EXISTING
SERVICES AND SITE CONDITIONS PRIOR TO COMMENCEMENT OF WORK. ANY
CLAIM FOR VARIATION ON THE BASIS OF LACK OF KNOWLEDGE WILL NOT BE
ACCEPTED.
5. ENSURE INVERT LEVELS AND MINIMUM COVER IS ACHIEVABLE PRIOR TO
COMMENCEMENT OF WORK ON SITE.
6. All PLUMBING AND DRAINAGE SERVICES THAT PENETRATE FIRE RATED WALLS
AND FLOORS MUST BE INSTALLED TO COMPLY WITH THE REQUIRED FIRE
RESISTANCE LEVEL.
STORMWATER NOTES
1. All STORMWATER DRAINAGE SHAILL BE 1001.11.111 AND BE INSTALLED AT 1:100
MINIMUM GRADE (UNO).
2. OOWNPIPES TO HAVE MINIMUM CROSS SECTlONAIL AREA EQUAIL TO 100MM
3.
(UNO).
ROOF GUTTERS AND DOWNPIPES TO FULLY COMPLY WITH THE REQUIREMENTS
OF AS/NZS3500.3.
- SITE PHOTO
NTS
MATERIALS
,
,
1. WATER SERVICES -
TO AS/NZS 3500 >
2. SANITARY DRAINAGE -
PVC CLASS DWV
3. SANITARY PLUMBING -
PVC CLASS DWV
4. DOWNPIPES -
PVC CLASS DWV(UNO)
5. STORMWATER UP TO 300MM -
PVC CLASS SW HEAVY (UNO)
6. STORMWATER OVER 300MM -
CONCRETE (RUBBER RING JOINT) CL.3/FRC
(SUPERTlTE) CLASS 2
,
7. SUBSOIL DRAINAGE -
100MM PERFORATED PVC IN FILTER SOCK (UNO) Development Counter
8. FIRE SERVICES ABOVE GROUND ONE STEEL "FIRE PLUS" MEDIUM
III
-
’".~~’:<.’
.
.
9. FIRE SERVICES BELOW GROUND -
PVC-M (BLUE RHINO) \ 1 19 APR 2012
(/ ’~’:
10. TRADE WASTE INGROUND
11. TRADE WASTE ABOVE GROUND
-
HOPE OR VITRIFIED CLAY
-
HOPE OR POLYPROPYLENE
,
,
"-----1
1
1
’.~ .,i,;’;’.
I
Tewantin
1,;~!i~J
ABBREVIATIONS 0 0’ 1
DP DOWNPIPE
h
, r-_
,I ~
e
HV
EXISTING
HYDRANT VALVE
--J
tii
IC
10
INSPECTION CHAMBER
INSPECTION OPENING
l ~
10S INSPECTION OPENING TO SURFACE
==
\
~
MH MANHOLE n
\ o
SW
UNO
STORMWATER
UNLESS NOTED OTHERWISE \ ~
LEGEND
~ r- r- r A 20l03I12 a.IENT
llLJ " ISSUE DATE REVISION STArus
STORMWATER ,
EXIST SEWER s ian bradford
EXIST STORMWATER sw
, plurnblng consultants
EXIST WATER w , ptyltcf
. .IF..(07)......3815
, ian bradford ::c;:~~
, plumbing eonaulunu p aaACH CWS’73
pty Itd .
E._Gape com.a.
.W.www~
BSA LICENCE NUMBER:-1121367
LICENCE CLASS:- HYDRAULIC SERVICES DESIGN
( \ (Including on site wastewater management)
) ( \
PROJECT
STORMWATER DRAINAGE ALTERATIONS
TELSTRA TELEPHONE EXCHANGE
\
\, ~ 30 WYANDRA STREET. NOOSA HEADS
l1TlE
HYDRAULIC SERVICES
~ COVER SHEET
REV
Cl DWGNO
SITE PLAN
~~~f:!R
,
=
McTAGGART PLUMBING
1:100 PLAN FOR DETAILS)
12027"1 A
PTYLTD
’~,
A2 SCALE AS NOTED SHEET 1 OF 2
Page 3
eDP STORMWATER CALCULATIONS
ROOF AlREA = 340m’
RAINFAll INTENSllY (1 IN 20 YR) -
251mm/hr.
ESTIMATED FLOW = 24 UTRES/SECOND
SW DRAINAGE THROUGH WAll TO UNDERCROFT
1
1 / EXISTING 100mm’ DOWNPIPES
L CONNECT TO NEW 15011
p~ ( STORMWATER DRAINAGE
FOR EACH DP)
(lYPlCAL
"-
1 1
"-
1
"-
’-- _ _
_1. _
___1 18
"-
1
o 0"-
SW DRAINAGE SUSPENDED BELOW
"-)’~ 1
FLOOR IN UNDERCROFT ~ 1
"- 1
"-~ SW DRAINAGE THROUGH WAll
AND DROPS ON OUTSIDE WALL
TO RUN INGROUND
l
\
600’ GRATED GULLY PIT
t:i
~
"- ~
o
z
"-
~
"-
"-
SW DRAINAGE ABOVE DOORS 600’ GRATED GULLY PIT
DROPPER TO RUN BELOW
"-~ EXCAVATE UNDER EXISTING PATH
VENTILATION GRILL
"- TO AllOW INSTAll OF 15011
STORMWATER DRAINAGE ALL-
SW DRAINAGE DROPS TO RUN "- TO SUNSHINE COAST REGIONAL
INGROUND COUNCIL APPROVAL
"-
"- ESTIMATED FLOW 24
L1TRES/SECOND
"- 15011 CONNECTS TO EXISTING
"- KERB GULLY CONNECTION TO BE
All TO SUNSHINE COAST
"- REGIONAL COUNCIL APPROVAL
A 2003/12 CUENT
ISSUE DATE REVISION STATUS
ian bradford
plumbing consultants
ptyltd
. PIF..(07)U4ISI’IS
. 11.0112654588
. P080X3M
plumbing consultants ___04573
pty Itd ..-..0-
.W.www~
BSA LICENCE NUMBER:-1121367
LICENCE CLASS:- HYDRAULIC SERVICES DESIGN
(including on site wastewater management)
PROJECT
STORMWATER DRAINAGE ALTERATIONS
TELSTRA TELEPHONE EXCHANGE
30 WYANORA STREET, NOOSA HEADS
TITlE
HYDRAULIC SERVICES
PART SITE PLAN
~~!SITE PLAN
REV
CUENT OWGNO
McTAGGART PLUMBING
12027.2 A
PTYLTD
A2 SCALE 1:100 U.N.O. SHEET2 OF 2