05 OF 07
120°48'20" 120°48'20"
EMT L 2m2 2.0 SITE AREA (LOT 1) 3037m2
(SP 197517) 47.889
124.17 123.82 123.76 123.46 123.46 123.22 122.95 122.77 122.56 122.31 AREA GROUND MEZZ
FLOOR FLOOR
2.0 123.59 123.17 EXISTING TENANCY 1 323.0m2 132.6m2
30°47'20" 123.93
LANDSCAPE122.89122.77
122.94 TENANCY 2 321.2m2 133.0m2
30°47'20"
124.26 2.829 122.47
TENANCY 3 491.3m2 192.2m2
BUFFER
10.001
123.45
255°48'30" 123.11 123
124.11 122.82 476.4m2 122 TOTAL 1135.5m2 457.8m2
122.35 GRAND TOTAL 1593.3m2
1 24
RETAINING WALL RETAINING WALL
SPOON DRAIN TO ENGINEERS 123.63 TO ENGINEERS TOTAL SITE COVER 40.7% 1236.3m2
TO 124.06 DETAILS Vegetation DETAILS SPOON DRAIN
ENGINEERS 123.36 TO ENGINEERS
DETAILS
124.17 DETAILS
123.19
124.17 124.12 Buffer
SPOON DRAIN TO ENGINEERS DETAILS
122.60 LANDSCAPE REQUIRED 15.6 % 455.5m2
8.351 123.94 123.69
SHW
124.05 123.14
MV VAN
300°47' 5400L x 3000W
18 122.80 LANDSCAPE PROVIDED 23.4 % 712.4m2
TURNING BAY
SF
2490 7308 5400L x 2500W
TYPICAL EXISTING LANDSCAPE 476.4m2
WC
ACCESSIBLE
920
SPOON DRAIN TO ENGINEERS DETAILS
CARPARK AMENITIES
RETAINING WALL 17
5400L x 2400W 6308
19 NEW LANDSCAPE 236.0m2
TO ENGINEERS STAFF 5400L x 2500W 123.03
DETAILS 123.50 D
SPOON DRAIN TO ENGINEERS DETAILS
CARPARK TYPICAL SCREEN
5400L x 2400W
16 CARPARK CAR PARKING REQUIRED 21
STAFF 20 122.71 122.45 05 OF 07
16.901 CARPARK 123.11 5400L x 2500W
122.83 CAR PARKING PROVIDED 21
30°47'20" 5400L x 2400W
15 123.173
12
TYPICAL
CARPARK
UP
STAFF 21 121.89 121 MOTOR BIKES REQUIRED 8
CARPARK 5400L x 2500W
122 121.86 121.83
MEZZ 3
ARTICULATED VEHICLE
TYPICAL
14
5400L x 2400W 122.31 CARPARK
120.99 MOTOR BIKES PROVIDED 8
121.93 RETAINING WALL
STAFF 192.2m2 121.76 TO ENGINEERS
LOADING BAY
CARPARK
190000x3500
FFL 125.4 120.84
13
DETAILS BICYCLES REQUIRED 5
120°47' 2000
5400L x 2400W
STAFF
8.12 CARPARK
121.95
121.82
121.78
BICYCLES PROVIDED 5
122.06
BOLLARDS
SPOON DRAIN
TO 12
ENGINEERS 5400L x 2400W
DETAILS STAFF
1968
2000
CARPARK
TENANCY 3
3 .95
11
5400L x 2400W
°27'22
STAFF
122.75 CARPARK
491.3m2 120.81
FFL 122.1
4# 2500L x 1200W
4# 2500L x 1200W
121.89
SPOON DRAIN TO ENGINEERS DETAILS
(to be confirmed by engineers)
BIKE PARKS
BIKE PARKS
0"
5400L x 2400W 7908 121.60
MOTOR
MOTOR
210°47'15"
STAFF
(72.414)
CARPARK 10 121.82 121.66 120.73
200mm
DOWN
121.75
STEP
123.10
5400L x 2400W 9
STAFF 121.61
CARPARK
TAYLOR
123 121.78
1332
5# ACCESS TO STAFF
BIKE
RACKS
AREA, MOTORBIKES
& BIKE RACKS
1 C
RETAINING WALL 5400L x 2500W
TO ENGINEERS TYPICAL
SP324340
BOLLARDS
DETAILS 1330 CARPARK 8
TENANCY 2 05 OF 07
3x3m MIN POROUS PAVED 121.58 121.42
120.76
STAFF RECREATIONAL
5400L x 2500W
TYPICAL
321.2m2
SPOON DRAIN TO ENGINEERS DETAILS
9100
AREA (COVERED 121.64 FFL 121.9
121
CARPARK 7
OUTDOOR TABLE & (to be confirmed by engineers)
SEATING) 121.62 121.42
COURT
5400L x 2500W
TYPICAL 120.64
3252 CARPARK 6 121.57
ACCESSIBLE
1.8m HIGH 5400L x 2500W
MEZZ 2 AMENITIES
FENCE
TYPICAL 121.72 133.0m2 MV VAN
CARPARK 5 FFL 125.2
200mm
DOWN
WC
LOT 1
SCREEN
STEP
SF
5400L x 2500W
3037m2 UP 920
EMT 97517)
TYPICAL SHW
(SP1
122.38 CARPARK 4 121.39
121.48 120.66
F 69
5400L x 2500W
0"
TYPICAL
120.56
6 Lorraine Avenue
3
CARPARK 3
22°28'4
2
122.22
m2
121.67
B Marcoola Beach, QLD, 4573
BOLLARDS
121.48
33.8
5400L x 2500W
TYPICAL
TENANCY 1 07 5448 8500
05 OF 07 CARPARK 2 323.0m2 [email protected]
5400L x 2400W 121.63 FFL 121.7 www.buildingsuncoastgreen.com.au
ACCESSIBLE
CARPARK 1
(to be confirmed by engineers) QBCC Licence No. 65942
121.52
PROPOSED 121.84 5400L x 2400W
BOLLARD
MEZZ 1 121.08 ACCESSIBLE
AMENITIES
T
S
R
25.10.22
14.10.22
12.10.22
ADDED FENCE & SLIDING GATES
PANEL COLOUR CHANGES
CLIENTS / CIVIL CHANGES
SB
SB
SB
DJ
DJ
DJ
SHARED AREA 120.54
LANDSCAPE
4102
132.6m2 Q
P
O
28.09.22
01.09.22
25.08.22
CLIENTS / PLANNERS CHANGES
CLIENTS CHANGES / 3D VIEW
DEBBIES CHANGES
SB
SB
SB
DJ
DJ
DJ
SCREENED FFL 125.0 120.43 N 24.08.22 NEW DESIGN ISSUED SB DJ
MV VAN
236.0m2 34 0. 121.65
1.8m HIGH BIN ENCLOSURE WC
M
L
16.06.22
14.06.22
ELEVATION NOTES ADDED
REAR BUILDING ALTERED RFI
SB
SB
DJ
DJ
SCREEN
FENCE 2# 2100 x 1500 & BIN K 13.06.22 RP PLAN SITE BOUNDARIES ALTERED SB DJ
1
2° 96
00
WASH DOWN AREA
UP 12 :0.3 P
Dia t:RC 920
SF
120.51 J
H-I
06.06.22
21.04.22
RFI CHANGES