Council archive · source document
Attachment 1- Noosa on Weyba Locality Code Final MCU12/0208
Very large file (28.0 MB): the whole original can take several minutes to open, especially on a phone. Text is quick to read.
Column 1 Column 2
Specific Solutions Probable Solutions
Flooding and Drainage S5.1 For new buildings or structures or
additions of more than 50m2 gross
O5 Buildings and other works are floor area to an existing building or
designed and sited to— structure, floor levels for habitable
a) provide flood free access to rooms are—
premises and flood free habitable a) for areas where minimum floor levels
areas; are available—not less than the
specified level;
b) allow only minor, short term and
b) for areas where flood modelling is
infrequent flooding of non-habitable
available—a minimum of 500mm
areas;
above the modelled flood level; and
c) ensure carparking areas can be c) for areas where flood modelling is not
adequately drained; available, a minimum of 500mm
d) ensure drainage does not adversely above the highest known flood level;
impact upon other premises; and
AND
e) ensure filling or excavation does not
adversely impact upon other S5.2 Where Council infrastructure is
premises by— available—
i. causing ponding of water on a) any drainage (from buildings and
the site or nearby land; land) flows to that infrastructure; and
ii. increasing flooding, which b) the infrastructure has the capacity to
adversely affects the safety accept any additional loading;
or use of any land upstream AND
and downstream; and
iii. adversely affecting the flow S5.3 For Residential Uses—
of water in any overland flow a) where slab on ground construction is
used, filling does not extend more than
path.
1m beyond the building footprint and
access to car parking areas, measured
from outer walls of the building; or
b) the design consists of a suspended
floor construction;
AND
S5.4 Car parking and maneuvering areas
are constructed at a level that
permits the parking area to drain
from the site by gravity means,
without the need for mechanical
pumping; or
S5.5 Basements for residential uses have
flood immunity above the Q100
where alternative means to
mechanical pumping are used to
achieve such immunity; or
S5.6 Basements for non-residential uses
have flood immunity above the
Q100 that may be achieved by
36
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Attachment 1- Noosa on Weyba Locality Code Final MCU12/0208Related documentApplication case desk ↗
About this file
- File size
- 28.0 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.