Column 1                                        Column 2
Specific Solutions                              Probable Solutions


Flooding and Drainage                            S5.1 For new buildings or structures or
                                                          additions of more than 50m2 gross
O5      Buildings and other works are                     floor area to an existing building or
      designed and sited to—                              structure, floor levels for habitable
   a) provide flood free access to                        rooms are—
      premises and flood free habitable             a)  for  areas where minimum floor levels
      areas;                                            are    available—not less than the
                                                        specified level;
   b) allow only minor, short term and
                                                    b) for areas where flood modelling is
      infrequent flooding of non-habitable
                                                        available—a minimum of 500mm
      areas;
                                                        above the modelled flood level; and
   c) ensure carparking areas can be                c) for areas where flood modelling is not
      adequately drained;                               available, a minimum of 500mm
   d) ensure drainage does not adversely                above the highest known flood level;
      impact upon other premises; and
                                                 AND
   e) ensure filling or excavation does not
      adversely       impact     upon     other S5.2 Where Council infrastructure is
      premises by—                                      available—
            i. causing ponding of water on          a) any drainage (from buildings and
                 the site or nearby land;               land) flows to that infrastructure; and
            ii. increasing flooding, which          b) the infrastructure has the capacity to
                 adversely affects the safety           accept any additional loading;
                 or use of any land upstream     AND
                 and downstream; and
            iii. adversely affecting the flow S5.3 For Residential Uses—
                 of water in any overland flow      a) where slab on ground construction is
                                                     used, filling does not extend more than
                 path.
                                                    1m beyond the building footprint and
                                                     access to car parking areas, measured
                                                    from outer walls of the building; or
                                                    b) the design consists of a suspended
                                                     floor construction;

                                               AND

                                               S5.4    Car parking and maneuvering areas
                                                       are constructed at a level that
                                                       permits the parking area to drain
                                                       from the site by gravity means,
                                                       without the need for mechanical
                                                       pumping; or

                                                S5.5   Basements for residential uses have
                                                       flood immunity above the Q100
                                                       where    alternative   means     to
                                                       mechanical pumping are used to
                                                       achieve such immunity; or

                                                S5.6   Basements for non-residential uses
                                                       have flood immunity above the
                                                       Q100 that may be achieved by


                                                                                            36

Used in these records

About this file

File size
28.0 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Attachment 1- Noosa on Weyba Locality Code Final MCU12_0208.pdf · 28.0 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.