Council archive · source document
SUPERSEDED Compiled Approved Plans - 51901.3604.02
Plans and drawings: the text below has words only, no drawings.
Very large file (25.5 MB): may take a few minutes to open.
Original PDF page 8, section 1. The text section number identifies this passage in the reader.
rev date issued details
Working Drawings
A 28.10.19 NV Building Approval
legend
AC - # aircon. unit
BAL- # balustrade
CLA- # cladding
CLG- # ceiling type
DP- # downpipe
DR- # drain
FLF- # floor finish
G-# gates
HC hose cock A B C D E F G H
HR - # handrails
LFT - # lift
MTL - # metal work
6,180 6,020 6,180 4,130 6,770 2,400 3,800
PT - # painted finish
PBL - # pebbles
REN - # render
RFS - # roof system
T- # tile type
SO - # stone
SCN - # screen D13
SOF - # soffits
STA - # stairs 4.6
STR - # structure
SW sewer RFS-02
MSC# miscellaneous item roof level RL: TBC
refer to schedules for details
NOTE: all structural elements; including
all slabs, columns, beams, footings and
framing; to be in accordance with
engineer's design and detail.
SCN-03 REN-01 SCN-03 REN-01 REN-01 SCN-03 SCN-04
second level RL: TBC
CLA-01
REN-01
STR-02 lounge ceiling RL: 5,900
MTL-02 RFS-06 MSC-01
REN-01 reception ceiling RL: 5,400
2,600
500
LNG-02
3,000
D03 W06a
MSC-06 MSC-06
REN-02
planter D01 T-03 T-03
ground floor RL: 2,400
STR-01
D19
4.9
A Section
1.7 Scale 1:100
H G F E D C B A
3,800 2,400 6,770 4,130 6,180 6,020 5,904
REN-01 existing building existing building
STR-02
roof RL: 6,000
MTL-02 REN-01 REN-01 REN-01 REN-01
ceiling RL: 5,400
2,600
600
600
SCN-02 open SCN-02 open
3,000
3,000
MSC-06
MSC-07 T-03 REN-02 REN-02
REN-02 ground floor RL: 2,400
B Section
1.7 Scale 1:100
-
APPROVED PLAN
7 6 5 4 3 2 1
51901.3604.2
5,400 6,900 1,200 2,200 5,150 3,600
NOOSA COUNCIL
24 MARCH 2020
-
existing building SCN-04
existing building
D14 C
MTL-02
4.12
REN-01
MTL-03
A A
roof RL: 7,100 15
14
13
12
11
10
987654321
STR-02
1,100
1
2
3
4
5
6
PT-01 CLA-01 7
8
9
10
11
12
13
roof RL: 6,000 B 14
15 B
REN-01
ceiling RL: 5,400
SCN-01 LNG-01 C
600
REN-02
3,000
REN-01 G-03
SCN-03 W03 W04
MSC-08
T-01 REN-01
ground floor RL: 2,400
C Section
1.7 Scale 1:100
0. Keyplan
Scale
a: suite 6, 8 kingfisher drive, peregian beach, qld 4573
p: (07) 5471 3033 Scale ??? Culgoa Resort Stage 2 - Entry Alteration Scale 1:100 @A1
sparks architects www.sparksarchitects.com
5 Quamby Pl, Noosa Heads QLD 4567 Culgoa Point Beach Resort 106 NV Sections WD 3.1
sparks architects pty. ltd. abn 89 124 611 721
qld architect's registration No. 3974 project client job no. drawn drawing dwg no.
GSPublisherVersion 443.1.1.0
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
SUPERSEDED Compiled Approved Plans - 51901.3604.02.pdfRelated documentApplication case desk ↗
About this file
- File size
- 25.5 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.