Skip to the record
Noosa's #1 Council Tracker.

Original source · versioned page text

Bushfire Hazard Assessment & Management Plan v4 - 7 Triller Court, Pomona

Attached to the e-mail RAL21/0022 - 7 Triller Court_ Pomona - Response to Further Advice Matters & Change to app (1 Lot into 4).

of 47

Page text read automatically using OCR, there may be inaccuracies

Plans and drawings: the text below has words only, no drawings.

Log in to see the plans as drawn
Table of Contents
1.    Scope.......................................................................................................................................3
2. Introduction .............................................................................................................................3
3.    Where Do These Guidelines Apply? ...........................................................................................3
4. Water Supply Specification........................................................................................................4
      Figure 1 – Reticulated Hydrant System.....................................................................................................4
      Figure 2 – Use of Hydrant System............................................................................................................4
      Figure 3 – Hydrant Markers.....................................................................................................................5
      Figure 5 – Marker/directional arrow spacing detail..................................................................................5
      Figure 4 – Hydrant marker posts..............................................................................................................5
      Figure 6 – Location of cats eyes on a sealed roadway...............................................................................5
      Figure 6 – Hydrant System design to minimum standards........................................................................6
5.    Vehicle Access Requirements................................................................................................... 6
      Figure 7 – Vehicle Turning Provisions......................................................................................................7


                                                                             Glossary of Terms
      In this document, the terms are limited to the meanings described below.
        Building:                    A building is a fixed structure that is wholly or partly enclosed by walls or is roofed.

        Structure:                   For this document refer to definition of a Building.
        Fire Truck:                  A vehicle used to combat a fire. A typical fire truck (a pumper) is approximately 2.5m wide, 7.7m long
                                     and it is typically used in urban residential areas. Further specifications of fire trucks and larger trucks are
                                     available from the QFES if design solutions are required for specific situations.

        Hydrant:                     An assembly installed on a branch from a water pipeline, which provides a valved outlet to permit a supply
                                     of water to be taken from the pipeline for fire fighting. These include above and below ground hydrants.
        QFES:                        Queensland Fire and Emergency Services.
        Material Change              As per the Planning Act 2016
        of Use:
        Reconfiguration              As per the Planning Act 2016
        of a Lot:
        Reticulated                  Is a permanent infrastructure provided to deliver treated water to lots from an Urban Utility Authority
        Water Supply:                through a system of pipes, mains, control valves etc. for household or industrial use. It will supply
                                     uninterrupted water at a positive pressure for fire fighting purposes.
        Road or                      Construction which is specifically designed for all vehicle travel (may or may not include a sealed top
        Carriageway:                 surface layer).
        A Constructed                For the purpose of defining widths, includes the part of the road reserve set aside for traffic and also
        Road:                        includes roll-over kerbs but does not include the remaining part of the road reserve.
        Trafficable                  Refers to that width of the constructed road that is unimpeded by encroachments such as street furniture or
        Width:                       landscaping, and is available for free movement of fire trucks.


                             © State of Queensland (Queensland Fire and Emergency Services) 2019
                             The Queensland Government, acting through the Queensland Fire and Emergency Services (QFES), supports and encourages the dissemination and exchange of publicly
                             funded information and endorses the use of the Australian Governments Open Access and Licensing Framework (AusGOAL).
                             All Queensland Fire and Emergency Services material in this document – except the QFES logo, any material protected by a trademark, and unless otherwise noted – is
licensed under a Creative Commons Attribution 4.0 licence.
The Queensland Fire and Emergency Services has undertaken reasonable enquiries to identify material owned by third parties and secure permission for its reproduction. Permission may need to be
obtained from third parties to re-use their material.
Written requests relating to the copyright in this document should be addressed to:
Intellectual Property Coordinator
Legal Services, Ministerial and Executive Services
Public Safety Business Agency
GPO Box 9879, Brisbane 4001
EM: [email protected]

Disclaimer
To the extent possible under applicable law, the material in this document is supplied as-is and as-available, and makes no representations or warranties of any kind whether express, implied, statutory,
or otherwise. This includes, without limitation, warranties of title, merchantability, fitness for a particular purpose, non-infringement, absence of latent or other defects, accuracy, or the presence or
absence of errors, whether or not known or discoverable. Where disclaimers of warranties are not allowed in full or in part, this disclaimer may not apply.
To the extent possible under applicable law, neither the Queensland Government or the Queensland Fire and Emergency Services will be liable to you on any legal ground (including, without limitation,
negligence) or otherwise for any direct, special, indirect, incidental, consequential, punitive, exemplary, or other losses, costs, expenses, or damages arising out of the use of the material in this
document. Where a limitation of liability is not allowed in full or in part, this limitation may not apply.

2                                                                                             - Public -                                               Fire Hydrant Guidelines (Effective: 03/2019)
Log in to download the original file

Bushfire Hazard Assessment & Management Plan v4 - 7 Triller Court, Pomona.pdf · 4.1 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.