Approved Plan - MCU20-0111
Plans and drawings
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawn -
NOTES
APPROVED PLAN 1. ENSURE CLEAR ACCESSIBLE PATH OF TRAVEL IS MAINTAINED IN
MCU20/0111 ACCORDANCE WITH AS1428.1 REQUIREMENTS
2. NEW CONSTRUCTION TO COMPLY WITH BCA SECTION J ENERGY
NOOSA COUNCIL EFFICIENCY REQUIREMENTS. CONFIRM WITH CERTIFIER.
3. ENSURE FOOD PREPARATION AREAS COMPLY WITH RELEVANT
21 JANUARY 2021 STATUTORY REQUIREMENTS.
-
90 90 90 90 90 90 90
1900 2015 2000 2000 3000 2000 10525
STORE COLD ROOM DRY STORE BAR FOYER
90 90
6295 6635
KITCHEN TENANCY (COS)
4780 1515
TO ALIGN WITH COL (COS) OPEN
LINE OF JETTY BELOW
NEW AUTOMATIC SLIDING DOOR.
PROVIDE DOOR THRESHOLD
STRIP TO COMPLY WITH B A B A
AS1428.1 CLAUSE 7. ENSURE EXTEND EXISTING AWNING ROOF TO
MINIMUM 850MM CLEAR COVER NEW DOORWAYS. REPLACE
OPENING. BOWED TIMBER IN EXISTING
AWNING.
NEW LINTEL OVER TO ROOF TO BE EXTENDED PREVIOUS EXTENT OF EXISTING
STRUCTURAL ENG. SPEC. TO COVER NEW AWNING
DECK AREA RELOCATED AUTOMATIC
PORTION OF BUILDING
SLIDING DOOR. CONFIRM NEW REPLACE BOWED TIMBER IN
LOCATION ON SITE. ENSURE EXISTING AWNING.
EXTEND EXISTING WALL & ROOF FULL COMPLIANCE WITH
OVER TO COVER NEW COLD PREVIOUS EXTENT OF
AS1428.1 REQUIREMENTS & ROOF
ROOM. EXTERNAL CLADDINGS TO BCA FIRE EGRESS
MATCH EXISTING. REQUIREMENTS.
AWNING OVER
FALL
EXISTING ROOF UNDER AWNING ROOF EXTENSION EXISTING AWNING ROOF
90
D01 W03 DP
90
DP LINE OF ROOF OVER DP DP
90
COL EXISTING EAVE GUTTER
1000
NOT IN SCOPE
RELOCATED DOOR
W06 W04
510 90
DRY STR
FOYER
2120
EXISTING EAVE GUTTER
DRY
2310
COLD ROOM
FOYER DP
NEW ROOF
COLD STORE
SERVERY
3500
NOT IN SCOPE
EXIST. ROOM
1300
FALL
BAR
BAR
ESCAPE
PATH
90
FIRE
STORE EXISTING AMENITIES
FALL
90
W05 DP
300 500
DP EXISTING ROOF
1100
1000
NOT IN SCOPE
SINK
90
90
1020 650
600 BENCH EXISTING DOWNPIPE
1560
CONFIRM COMPLIANCE OF ONTO ROOF BELOW
1670
EXISTING ENTRY DOOR WITH
500 BENCH
NEW DOWNPIPE CERTIFIER. PROVIDE
2970
KITCHEN COL COL THRESHOLD STRIP TO
NEW DP
EXISTING EAVE GUTTER
AS1428.1 REQUIREMENTS
90
90
DP DP
90
D02
1300
FALL
700 BENCH CONFIRM FIRE SEPARATION
SERVERY
STORE(COS)
REQUIREMENTS TO
FALL
90
STORE
FALL
NEIGHBOURING BUILDING
2175
WITH CERTIFIER PRIOR TO
NOT IN SCOPE
NOT IN SCOPE
600 SERVERY
NEW FLOOR FINISHES TO ENTIRE HEAT LAMPS OVER CONSTRUCTION
Restaurant CENTRE TO CLIENT'S
FUNCTION NEW ROOF
SELECTION. ENSURE A D03 REUSE EXISTING EXHAUST
CONTINUOUS ACCESSIBLE PATH
E
RIDGE OVER COL HOOD - DETAIL BY
NC
OF TRAVEL IN ACCORDANCE WITH OTHERS
FE
90
AS1428.1 CLAUSE 7.
Restaurant
L
NG
FUNCTION CENTRE
AL
TENANCY
TI
W
IS
282m2 59m2
EX
T
OR
NEW COLUMN TO
PP
SU
ENG. DETAIL &
SPEC.
OF
NEW FLOOR FINISHES TO
RO
TENANCY TO CLIENT'S EXISTING ROOF
W
OF
SELECTION. ENSURE A
NE
NEW BEAM OVER COL BEAM OVER NEW ROOF
RO
CONTINUOUS ACCESSIBLE
COL PATH OF TRAVEL IN
NG
COL COL COL COL COL
ACCORDANCE WITH
RI
OU
FALL
AS1428.1 CLAUSE 7.
NEW TIMBER CEILING
HB
IG
JOISTS OVER TO ENG.
NE
EXISTING
FALL TO
SPEC.
MATCH
M
26
NG
.
ST
TI
DI
EXISTING TENANCY
IS
EL ENSURE DOOR THRESHOLDS
EX
AV
TR COMPLY WITH AS1428.1 WITH
IT NOT IN SCOPE
EX ADDITION OF NEW FLOOR
W07 COVERINGS
RELOCATED DOOR RELOCATED DOOR
LI
NE
W01 W02
OF
7° FALL
2580
JE
DECK AREA PRIVATE DECK
COS
TT
NEW AWNING ROOF
Y
72m2 10.5m2
BE
LO
90MM STUD WALL WITH
W
WEATHERBOARD CLADDING
ROOF OVER TO MATCH EXISTING DP
DP DP DP DP
DP NEW EAVE GUTTER DP DP
EXISTING EAVE GUTTER
ENSURE AT LEAST ONE DOORWAY NEW MIN 1M HIGH GLASS
NEW DOWNPIPES DRAINING
PROVIDES ACCESSIBLE B A BALUSTRADE TO MATCH
TO RIVER BELOW B A
WHEELCHAIR ACCESS TO DECK EXISTING. ENSURE
AREA IN ACCORDANCE WITH BCA COMPLIANCE WITH BCA
D3. CONFIRM ON SITE & WITH REQUIREMENTS LOCATE FASCIA/GUTTER TO
CERTIFIER. ENSURE DOWNPIPES CLEAR
TIMBER POSTS BELOW IN
NEW AWNING ROOF OVER EXISTING GLASS STRAIGHT RUN (NO BENDS)
BALUSTRADE
PROPOSED ROOF LAYOUT PLAN
NEW STAINLESS STEEL AWNING
SUPPORT POSTS FIXED TO TOP
OF EXISTING PIERS
SCALE 1:100
PROPOSED FLOOR LAYOUT
SCALE 1:100
5m
1m
SCALE 1:100
COPYRIGHT: NOTES: CLIENT: DRAWING TITLE:
THIS DRAWING AND THE INFORMATION SHOWN HEREON IS * ALL WORK TO BE DONE IN ACCORDANCE WITH B.C.A. & QUADRANT HOLDINGS PROPOSED FLOOR & ROOF
THE PROPERTY OF T.O.Z. PTY LTD AND MAY NOT BE USED
FOR ANY OTHER PURPOSE THAN THAT FOR WHICH THIS
ANY OTHER AUTHORITY HAVING JURISDICTION OVER THE
WORKS & PAY ALL FEES.
LAYOUTS
DRAWING IS SUPPLIED. ANY OTHER USE, COPYING OR -
REPRODUCTION OF ALL OR ANY PART OF THIS DRAWING IS * ALL RELEVANT DIMENSIONS TO BE CHECKED ON SITE -
PROJECT:
DATE: 03/06/20
PROHIBITED WITHOUT THE WRITTEN CONSENT OF T.O.Z. PTY. PRIOR TO COMMENCING ANY WORK. NO ALLOWANCE WILL
-
ALTERATIONS & ADDITIONS
LTD. BE MADE FOR FAILURE TO DO THIS
LOT 388 MCH839039 1:100
N
SCALE:
-
O
* THESE DRAWINGS TO BE READ IN CONJUCTION WITH NOOSA HARBOUR MARINA VILLAGE
R
CONSULTANTS DRAWINGS.
B - CLIENT AMENDMENTS 01/07/20 DRAWING No: 2260-A03
T
TEWANTIN, QLD
H
A - FOR INFORMATION 26/06/20
AMENDMENT: ISSUE: B
GSPublisherVersion 0.0.100.100