                                                                                                                                               NEW CEILING JOISTS TO STRUCTURAL ENG. SPEC
                                                                                                                                               BETWEEN EXISTING ROOF BEAMS (190x35 LVL @
                                                                                                                                               600CTRS NOMINAL - CONFIRM WITH ENGINEER)


                                                                                                                                               EXISTING ROOF STRUCTURE (CONFIRM
                                                                                                                                               ON SITE)
                                        EXISTING RIDGE 7.150 (ASSUMED)

                                                                                                                                                                                                                                                                                                                                                              COS
                                                                                     PROVIDE CEILING BATTS TO
                                                                                     RENOVATED AREAS IN ACCORDANCE                                                                                                                                                                              EXISTING JACK RAFTERS TO BE REMOVED
                                                                                     WITH BCA SECTION J REQUIREMENTS
                                                                                     (CONFIRM WITH CERTIFIER)
                                                                                                                                                                                                                                                                                                EXISTING STEEL ROOF BEAM (CONFIRM ON
                                                                                                                                                                                                                                                                                                SITE)                                                                      POLISHED S/S CHS POST SUPPORTING
                                                                                     EXISTING ROOF SHEETING TO REMAIN                                                                                                                                                                                                                                                      FASCIA BEAM ABOVE TO STRUCTURAL
                                                                                                                                                                                                                                                                                                ROOF SHEETING TO MATCH EXISTING                                            ENG. DETAIL & SPEC.
                                                                                                                                               SELECTED CEILING LINING
                                                                                                                                                                                                                                                                                7°              WITH FOIL FACED BLANKET UNDER

                                                                                     EXISTING AWNING TO BE EXTENDED.                           EXISTING ROOF STRUCTURE (CONFIRM
                                                                                     DETAIL TO MATCH EXISTING.                                 ON SITE)                                                                                                                                         GUTTER TO MATCH EXISTING                                                   POLISHED S/S CIRCULAR PLATE AS
                                                                                                                                                                                                                                                                                                                                                                           CAPPING TO EXISTING TIMBER POST




                                                                                                                                                                                                                                                                                                                                       TO MATCH
                                 5150




                                                                                                                                                                                                                                                                                                                                        EXISTING
                                                                                                                                               PROVIDE CEILING BATTS TO                                                                                                                         FASCIA BEAM TO STRUCTURAL ENG.
                                                                                                                                               RENOVATED AREAS IN ACCORDANCE                                                                                                                    SPEC.
                                                                                                                                               WITH BCA SECTION J REQUIREMENTS                                                                                                                                                                                             POLISHED S/S TUBE WELDED TO TOP
                                                                                                                                               (CONFIRM WITH CERTIFIER)                                                                                                                                                                                                    CAP. HEIGHT TO MATCH EXISTING
                                                                                                                                                                                                                                                                                                NEW RAFTERS TO STRUCTURAL ENG.                                             DETAIL ON PIER (COS).
                                                                                                                                                                                                                                                                                                SPEC.
                                                                                     NEW DOORWAY IN EXISTING WALL.                             EXISTING POSTS & ROOF BEAM
                                                                                     PROVIDE LINTEL OVER TO STRUCTURAL                                                                                                                                                                          SELECTED EAVE LINING (CONFIRM                                              S/S FLAT BAR WELDED TO CAPPING
                                                                                     ENG. SPEC.                                                                                                                                                                                                 WITH CLIENT)                                                               PIECE, INSERTED INTO CENTRE OF
                                                                                                                                               NEW DOOR AS SCHEDULED                                                                                                                                                                                                       EXISTING TIMBER POST

                                                                                                                             SERVICE HALLWAY                        Restaurant
                                                                                                                                                                     FUNCTION CENTRE                                                                                     DECK
                                                                                     THRESHOLD STRIPS AT CHANGES IN                                                                                                                                                                                                                                                        S/S BOLTS THROUGH POST
                                                                                     FLOOR FINISH TO COMPLY WITH                               NEW FLOOR FINISH TO CLIENT'S                                                                                                                     NEW STAINLESS STEEL POST &
                                                                                     AS1428.1 CLAUSE 7                                         SELECTION. ENSURE A CONTINUOUS                                                                                                                   CAPPING AS DETAILED
                                                                                                                                               ACCESSIBLE PATH OF TRAVEL IN
                                                                                                                                               ACCORDANCE WITH AS1428.1 CLAUSE                                                                                                                                                                                             EXISTING TIMBER POST
                                                                                                                                               7.                                                                                                                                               EXISTING GLASS BALUSTRADE
                                        EXISTING FLOOR LEVEL 2.000 (ASSUMED)
                                                                                                                                                                                                                                                                                                NEW GUTTER DISCHARGING TO RIVER

                                                                                                                                                                                                                                                                                                EXISTING POST

                                                                                                                                                                                                                                                                                                EXISTING BI-FOLD DOORS

                                                                                                                                                                                                                                                                                                EXISTING TIMBER PIERS                                 AWNING POST FIXING
                                                                                                                                                                                                                                                                                                                                                      SCALE         1:10




                                             SECTION A-A
                                             SCALE          1:50




                                                                                     ROOF SHEETING OVER TO MATCH EXISTING,
                                                                                     WITH FOIL FACED BLANKET UNDER

                                        EXISTING RIDGE 7.150 (ASSUMED)                                                                                                                                                                                                                          NEW ROOF BEAM TO STRUCTURAL ENG.
                                                                                                                                                                                                                                                                                                SPEC.
                                                                                     TRUSS ROOF TO MANUFACTURER'S
                                                                                     SPECIFICATIONS

                                                                                                                                                                                                                                                                                                NEW ROOF BEAM TO STRUCTURAL ENG.
                                                                                                                                                                                                                                                                                                SPEC.


                                                                                                                                                                                                                                                                                                ROOF SHEETING TO MATCH EXISTING
                                                                                                                                                                                                                                                                                                WITH FOIL FACED BLANKET UNDER
                                                                                                                                                                                            PROVIDE INSULATION TO NEW STRUCTURE
                                                                                                                                                                                            IN ACCORDANCE WITH BCA SECTION J                                                    7°
                                                                                                                                                                                            REQUIREMENTS (CONFIRM WITH CERTIFIER)
                                                                                                                                                                                                                                                                                                GUTTER TO MATCH EXISTING

                                                                                                                                                                                            STUD WALL WITH WEATHERBOARD LINING
                                 5150




                                                                                                                                                                                                                                                                                                FASCIA BEAM TO STRUCTURAL ENG.
                                                                                                                                                                                                                                                                                                SPEC.


                                                                                                                                                                                                                                                                                                NEW RAFTERS TO STRUCTURAL ENG.
                                                                                                                                                                                                                                                                                                SPEC.
                                                                                     EXISTING WEATHERBOARD LINING                                                                           NEW TIMBER STUD WALL INSIDE EXISTING
                                                                                                                                                                                            FENCE. ENSURE CONTINUOUS MEMBRANE
                                                                                                                                                                                            IS PROVIDED AROUND BUILDING ENVELOPE                                                                SELECTED EAVE LINING (CONFIRM
                                                                                     NEW STUD WALL WITH WEATHERBOARD                                                                                                                                                                            WITH CLIENT)
                                                                                     LINING
                                                                                                                                                                                            NEW POST TO STRUCTURAL ENG.             Restaurant
                                                                                                                                                             STORE                          SPEC                                      FUNCTION CENTRE                    DECK
                                                                                                                                                                                            NEW FLOOR FINISH TO CLIENT'S                                                                        NEW STAINLESS STEEL POST &
                                                                                                                                                                                            SELECTION. ENSURE A CONTINUOUS                                                                      CAPPING AS DETAILED
                                                                                                                                                                                            ACCESSIBLE PATH OF TRAVEL IN
                                                                                                                                                                                            ACCORDANCE WITH AS1428.1 CLAUSE 7.
                                                                                                                                                                                                                                                                                                EXISTING GLASS BALUSTRADE
                                        EXISTING FLOOR LEVEL 2.000 (ASSUMED)

                                                                                                                                                                                                                                                                                                EXISTING POST


                                                                                                                                                                                                                                                                                                REOLCATED BI-FOLD DOORS

                                                                                                                                                                                                                                                                                                EXISTING TIMBER PIERS

                                                                                                                                                                                                                                                                                                                                                                                                              -
                                                                                                                                                                                                                                                                                                                                                                                           APPROVED PLAN
                                                                                                                                                                                                                                                                                                                                                                                              MCU20/0111
                                             SECTION B-B                                                                                                                                                                                                                                                                                                                                   NOOSA COUNCIL
                                             SCALE          1:50
                                                                                                                                                                                                                                                                                                                                                                                           21 JANUARY 2021
                                                                                                                                                                                                                                                                                                                                                                                                             -




 COPYRIGHT:                                                              NOTES:                                                                                                                                                                                                                                                                    CLIENT:                                        DRAWING TITLE:
 THIS DRAWING AND THE INFORMATION SHOWN HEREON IS                        * ALL WORK TO BE DONE IN ACCORDANCE WITH B.C.A. &                                                                                                                                                                                                                         QUADRANT HOLDINGS                              SECTIONS A-A & B-B
 THE PROPERTY OF T.O.Z. PTY LTD AND MAY NOT BE USED                      ANY OTHER AUTHORITY HAVING JURISDICTION OVER THE
 FOR ANY OTHER PURPOSE THAN THAT FOR WHICH THIS                          WORKS & PAY ALL FEES.
 DRAWING IS SUPPLIED. ANY OTHER USE, COPYING OR                                                                                                                                                                                                         -
 REPRODUCTION OF ALL OR ANY PART OF THIS DRAWING IS                      * ALL RELEVANT DIMENSIONS TO BE CHECKED ON SITE                                                                                                                                -
                                                                                                                                                                                                                                                                                                                                                   PROJECT:
                                                                                                                                                                                                                                                                                                                                                                                                  DATE:           03/06/20
 PROHIBITED WITHOUT THE WRITTEN CONSENT OF T.O.Z. PTY.                   PRIOR TO COMMENCING ANY WORK. NO ALLOWANCE WILL
                                                                                                                                                                                                                                                        -
                                                                                                                                                                                                                                                                                                                                                   ALTERATIONS & ADDITIONS
 LTD.                                                                    BE MADE FOR FAILURE TO DO THIS
                                                                                                                                                                                                                                                        -                                                                                          LOT 388 MCH839039                              SCALE:          1:50, 1:10
                                                                         * THESE DRAWINGS TO BE READ IN CONJUCTION WITH
                                                                         CONSULTANTS DRAWINGS.
                                                                                                                                                                                                                                                        B - CLIENT AMENDMENTS        01/07/20                                                      NOOSA HARBOUR MARINA VILLAGE                   DRAWING No:     2260-A05
                                                                                                                                                                                                                                                        A - FOR INFORMATION          26/06/20                                                      TEWANTIN, QLD
                                                                                                                                                                                                                                                        AMENDMENT:                                                                                                                                ISSUE:          B
GSPublisherVersion 0.0.100.100
Log in to download the original file

Approved Plan - MCU20-0111.pdf · 3.1 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.