Council archive · source document
Approved Plans OPW18-0080 · OPW18/0080
Plans and drawings: the text below has words only, no drawings.
00
43 RE-SHAPE EXISTING JETTY -
EXISTING 'Y' HEAD AREA: 12.69m2
NOOSA COUNCIL
GENERAL NOTES
PROPOSED 'T' HEAD AREA: 10.32m 2
(AREA TO BE ADDED) (AREA TO BE REMOVED) APPROVED PLAN
DO NOT SCALE PLANS, USE WRITTEN DIMENSIONS ONLY. IF IN DOUBT, ASK. approx 0.277m 2 approx 0.8m 2
THE OWNER/BUILDER SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS, LEVELS,
45
OPW18/0080 21 MAY 2018
24
SETBACKS AND SPECIFICATIONS PRIOR RO COMMENCING WORKS OR ORDERING 34
00
LAWN / GROUND COVER
MATERIALS AND SHALL BE RESPONSIBLE FOR ENSURING THAT ALL BUILDING WORKS
24
CONFORM TO THE NATIONAL CONSTRUCTION CODE OF AUSTRALIA, CURRENT
CANAL
00
AUSTRALIAN STANDARDS, BUILDING REGULATIONS AND TOWN PLANNING
45
00
REQUIREMENTS, REPORT ANY DISCREPANCIES TO THIS OFFICE.
ALL WORKS SHALL COMPLY WITH BUT NOT LIMITED TO THE BUILDING CODE OF
AUSTRALIAN AND THE AUSTRALIAN STANDARDS LISTED IN NOTE 4.
1 x BOAT LIFTING DEVICE
AS 1288 - 2006 GLASS IN BUILDINGS - SELECTION AND INSTALLATION 3.0m WIDE
AS 1562 - 2006 DESIGN AND INSTALLATION OF SHEET ROOF AND WALL CLADDING
AS 1684 - 2010 NATIONAL TIMBER FRAMING CODE LAWN / GROUND COVER
AS 2049 - 2002 ROOF TILES GARDEN BED
AS 2050 - 2002 INSTALLATION OF ROOF TILES
AS 2870 - 2011 RESIDENTIAL SLAB AND FOOTINGS - CONSTRUCTION PROPOSED ENTERTAINING DECK
HARD PAVEMENT 22.5m2
AS/NZS 2904 - 1998 DAMP-PROOF COURSES AND FLASHINGS
AS 3600 - 2010 CONCRETE STRUCTURES
94
22.8 / 90m2 = 25%
WORKS WITHIN THE
00
AS 3660 - 2004 BARRIERS FOR SUBTERRANEAN TERMITES
AS 3700 - 2011 MASONRY IN BUILDINGS
AS 3740 - 2010 WATERPROOFING OF WET AREAS IN RESIDENTIAL BUILDINGS PROPERTY AREEXISTING
NOT PART
AS 3786 - 2004 SMOKE ALARMS TERRACE
OF THIS PERMIT.
AS 4055 - 2012 WIND LOADINGS FOR HOUSING Lawn / Ground cover
AS 4100 - 2012 STEEL STRUCTURES
THESE PLANS SHALL BE READ IN CONJUNCTION WITH ANY SOIL, STRUCTURAL AND
CIVIL ENGINEERING COMPUTIONS AND DRAWINGS.
ALL BUILDINGS SHALL BE PROTECTED AGAINST TERMITE ATTACK IN ACCORDANCE
WITH AS 3660.1 AND A DURABLE NOTICE SHALL BE PLACED IN THE METER BOX
INDICATING TYPE OF BARRIER AND REQUIRED PERIODICAL INSPECTIONS.
SAFETY GLAZING TO BE USED IN THE FOLLOWINGS CASES -
EXISTING
46
i) ALL ROOMS - WITHIN 500mm VERTICAL OF THE FLOOR
00
ii) BATHROOMS - WITHIN 1500mm VERTICAL OF THE BATH BASE POOL
iii) FULLY GLAZED DOORS
iv) SHOWER SCREENS
v) WITHIN 300mm OF A DOOR AND <1200mm ABOVE FLOOR LEVEL
vi) WINDOW SIZES ARE NOMINAL ONLY, ACTUAL SIZES WILL VARY
WITH MANUFACTURER, AND ARE TO BE VERIFIED WITH SAME. FLASHING ALL ROUND.
STORMWATER TO BE TAKEN TO ON SITE STORAGE OF PROVIDED, THEN THE LEGAL
POINT OF DISCHARGE AS DETERMINED BY THE RELEVANT AUTHORITY.
TILED DECKS OVER LIVABLE AREAS ARE TO BE, IN THE FOLLOWING ORDER OVER THE
FLOOR JOISTS : 19mm COMPRESSED FIBRE CEMENT SHEET, WITH ONE LAYER OF
PARCHEM EMERPROOF 750 WITH A SECOND LAYER OF SAND SEED WITH A DFT OF
1300 MICRON, INSTALLED TO MANUF. SPECIFICATIONS, AND FLOOR TILES OVER, ALL
CORNERS TO HAVE 20mm MASTIC SEALANT UNDER THE PARCHEM EMERPROOF 750.
FOOTINGS ARE TO BE WHOLLY WITHIN TITLE BOUNDARIES AND ARE NOT TO ENCROACH
EASEMENTS. IT IS RECOMMENDED THAT WHERE BUILDINGS ARE TO BE LOCATED IN EXISTING
CLOSE PROXIMITY OF BOUNDARIES, A CHECK SURVEY BE CONDUCTED BY A LICENSED
SURVEYOR.
RESIDENCE
ALL STEELWORK IN MASONRY TO BE HOT DIP GALVANISED.
ALL WET AREAS TO COMPLY WITH BCA 3.8.1.2 AND AS 3740. SPLASH BACKS SHALL
BE IMPERVIOUS FOR 150mm ABOVE SINKS, TROUGHS AND HAND BASINS WITHIN
75mm OF THE WALL.
PROVIDE WALL TIES AT 600mm SPACINGS BOTH VERTICAL AND HORIZONTAL AND
WITHIN 300mm OF ARTICULATION JOINTS. BRICK TIES TO BE STAINLESS STEEL.
SUB-FLOOR VENTILATION MINIMUM 7500mm/sq FOR EXTERNAL WALLS AND
1500mm/sq FOR INTERNAL WALLS BELOW BEARER.
EXISTING
GARAGE
THERMAL INSULATION TO BE PROVIDED TO ACHIEVE MINIMUM REQUIREMENTS AS
SPECIFIED BY LICENSED ASSESSOR.
STAIR REQUIREMENTS : MIN. TREAD 240mm, MIN. RISER 115mm, MAX. RISER 190mm,
SPACE BETWEEN OPEN TREADS MAX. 125mm. TREADS TO BE NON SLIP SURFACE.
BALUSTRADES : MIN. 1000mm ABOVE LANDINGS WITH MAX. OPENING OF 125mm AND
IN ACCORDANCE WITH BCA 3.9.2
FOR STAINLESS STEEL BALUSTRADE, REFER TO Table 3.9.2.1 (WIRE BALUSTRADE EXISTING
CONSTRUCTION - REQUIRED WIRE TENSION AMD MAXIMUM PERMISSIBLE
DEFLECTION) OF THE BCA.
SITE PLAN DRIVEWAY
GE
THE BUILDER SHALL TAKE ALL STEPS NECESSARY TO ENSURE THE STABILITY OF SCALE : 1 : 200
EXISTING AND NEW STRUCTURES THROUGH-OUT CONSTRUCTION.
DENOTES LOCATION OF SMOKE DETECTORS (refer electrical layout plans), A
R S
TO BE HARD WIRED WITH EMERGENCY BACK-UP AND COMPLY WITH AS 3786. O R
PROVIDE LIFT OFF HINGES, OPEN OUT DOOR OR MIN 1200mm CLEARANCE FROM DOOR
TO PAN IN WATER CLOSETS.
N CH ATE 20
EXHAUST FANS FROM SANITARY COMPARTMENTS ARE TO BE DUCTED EXTERNALLY
E
A W 1 04
OR TO A VENTED ROOF SPACE IN COMPLIANCE WITH AS 1668.2
A 9
THESE NOTES ARE NEITHER EXHAUSTIVE NOR A SUBSTITUTE FOR REGULATIONS,
N 0TH OS RP 8.9 m²
STATUTORY REQUIREMENTS, BUILDING PRACTICE OR CONTRACTUAL OBLIGATIONS.
3 NO 8 3 79
THESE PLANS ARE PROTECTED BY COPY RIGHT AND ARE THE PROPERTY OF THE t 7 E A : 6253
AUTHOR. Lo AR
iD
: 1
3
Option G
DRAWING TITLE:
GENERAL NOTES: CLIENT NAME: David & Debbie Weeks
Use written dimensions only. DO NOT scale drawings. Contractors to verify all Site Plan SITE ADDRESS: 30 The Anchorage, Noosaville
dimensions and levels on site prior to commencing works and shop drawings.
Site location is Category N3 or to engineer's requirements.
These drawings are to be read in conjunction with engineer's design and Feb 2017 DRAWING No:
A001
ISSUE: H DATE: 21/05/2018 DATE:
details, the accompanying building specification and schedule of finishes.
Ph 0403 191 223 www.natanidesign.com qbcc 1243419 SCALE: 1 : 200 SHEET SIZE: A3
If in doubt, please request clarification. DO NOT ASSUME.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 1 page
Page 2
-
NOOSA COUNCIL
B C
APPROVED PLAN
A105 A105 OPW18/0080 21 MAY 2018
A
A105
D
A105
WORKS WITHIN THE
Existing Terrace PROPERTY ARE NOT PART
Planter Existing Pool OF THIS PERMIT.
very low hedge
Planter
very low hedge
DO
Planter Pool trough
WN
(pebbles)
8
Planting 7 Buil
shrubs & 6 t-in
Sea
ground cover 5 t
4
Drainage point
Existing pandanus Sitting WORKS WITHIN THE
flood water to enter and
freely drain away
DO
Deck PROPERTY ARE toNOT
Engineer'sPART
design Lawn
3D View 1
WN
3
2 OF THIS PERMIT. Lawn / Ground cover
1
Existing fence
Existing fence
1000
Lawn Lawn
Lawn / Ground cover
340
Lawn / Ground cover
Balustrade
timber handrail Setback to deck Revetment wall
Jetty
N
1 Boat lift device
3.0m wide
Gate
WORKS WITHIN THE
PROPERTY ARE NOT PART
OF THIS PERMIT.
3D View 2
SITTING DECK
Option G
DRAWING TITLE:
GENERAL NOTES: CLIENT NAME: David & Debbie Weeks
Use written dimensions only. DO NOT scale drawings. Contractors to verify all Sitting Deck SITE ADDRESS: 30 The Anchorage, Noosaville
dimensions and levels on site prior to commencing works and shop drawings.
Site location is Category N3 or to engineer's requirements.
These drawings are to be read in conjunction with engineer's design and Feb 2017 DRAWING No:
A101
ISSUE: H DATE: 21/05/2018 DATE:
details, the accompanying building specification and schedule of finishes.
Ph 0403 191 223 www.natanidesign.com qbcc 1243419 SCALE: As indicatedSHEET SIZE: A3
If in doubt, please request clarification. DO NOT ASSUME.
Used in these records
Approved Plans OPW18-0080.pdfRelated documentApplication case desk ↗
About this file
- File size
- 397 KB (small file)
- File type
No other editions are linked here.