Appendix 5 - Air quality assessment report

of 35

Page text shows just the words. Original shows the document exactly as it was published.

                               Averaging Time,            Ambient Pollutant
          Pollutant                                                                                             Station
                                  Statistic             Concentration (µg/m3)
                            24 hours, 70th percentile                  22.4
                           Maximum Annual Average                      18.5
                              24-hr, 70th percentile                   47.1
         Total Xylenes                                                                                        Springwood
                           Maximum Annual Average                      41.3



4.8          Emission Parameters
Fugitive emissions from refuelling areas have been modelled as volume sources (one per rank of
bowsers, total of 4) at a height of 1.0 m above ground with horizontal and vertical dispersion values
of 1.0 m. Vent stack emission parameters for the petrol vent have been modelled with the following
parameters:

⚫ Diameter (m) – 0.1;
⚫ Velocity (m/s) – 0.1;
⚫ Temperature – Ambient; and
⚫ Height (m) – 4.


5            Summary of Assumptions
Below is a list of key assumptions considered in the modelling:

⚫ It is assumed that 40 kL bulk tanker deliveries occur continuously throughout the day (24/7). In
    reality, tanker deliveries would likely occur a few times a week only;

⚫ all fuel handling is considered to be petrol providing a conservative emissions generation
    procedure (i.e., petrol has a higher volatility than diesel);

⚫ for tank filling, a maximum fuel delivery of 40 kL/hour has been considered;
⚫ worst case CAPCOA “whoosh” emissions adopted to represent slightly higher volatility of
    Australian fuels;



5.1          Modelling Results
Table 4.4 presents the predicted maximum concentrations at the adjacent residential receptors. The
results of the modelling show compliance with the air quality goals at all discrete receptors. The
highest pollutant concentrations are predicted at 4.5m above ground (second storey of nearest
dwellings). Figures 4.8 and 4.9 presents the predicted ground level and first floor concentrations of
odour.




                                                                                                                              Page 29 of 35
                                                        Belo Developments- Air Quality Assessment - Proposed Service Station, Noosaville
                                                                                    /Network/Projects/4694.2/Reporting/4694.2-AirReport02.odt
Log in to download the original file

Appendix 5 - Air quality assessment report.pdf · 3.8 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.