GOOD SHEPHERD LUTHERAN COLLEGE Odyssey Consulting Group Lot 30 on SP170751 Conceptual Stormwater Management Plan 115 Eumundi Noosa Road, Noosaville Project No: K4277 Figure 3: Mitigated Post Development Catchment Q100 Flow Rates Catchment A will be collected by a detention tank to mitigate flows to less than that of the pre development scenario and will discharge to a LPOD on Eumundi Noosa Road. With reference to Figure 3 the detention arrangement can be seen to effectively mitigate the post development flows in all storm events for the proposed site. 3 The hydraulic analysis using the DRAINS model has determined that a minimum of 126 m of storage is required for runoff attenuation and is to be provided in the form of a detention tank located within the open space area. Refer to Odyssey Consulting Group, Stormwater Management Plan (Ref: K4277/P007/D) and Odyssey Consulting Group, Stormwater Detention and Bio retention Details (Ref: K4277/P010/C) included as Appendix F, for details of the tank arrangement, indicative location and preliminary stormwater layout. The final location onsite and construction levels will be determined at detailed design stage. A copy of the DRAINS model used in this report can be made available to Council upon request. 5.0 WATER QUALITY ASSESSMENT 5.1 Background The development of land has the potential to increase the pollutant loads within stormwater runoff and downstream watercourses. During the construction phase of the development disturbance to the vegetation on the site has the potential to significantly increase sediment loads entering downstream watercourses. The operational phase of the development will increase the density of residential land use potentially increasing the amount of sediments and nutrients washing from the site. The following sections describe the predicted increase in pollutant loads generated by the proposed development and treatment devices to mitigate the potential increases. In accordance with industry guidelines suspended solids, nitrogen and phosphorus will be targeted for reduction during the operational phase of the development. K4277-0002-C 05 November 2018 Page 9 of 16
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.