GOOD SHEPHERD LUTHERAN COLLEGE Odyssey Consulting Group Lot 30 on SP170751 Conceptual Stormwater Management Plan 115 Eumundi Noosa Road, Noosaville Project No: K4277 3.3.2 Coefficient of Runoff The post development coefficient of runoff (C year) was determined based on the fraction impervious 2 (fi) method as specified in QUDM. The proposed development has a total impervious area of 4,513 m 1 which equates to a fraction impervious value of 0.9. Using a one hour, ten year rainfall intensity ( I10) of 72.3 mm/hr, a C10 value of 0.88 has been adopted for the post development scenario. With reference to QUDM Table 4.05.3, applying the frequency factors for the standard storms of 2, 10, 20 and 100 years results in the following post development coefficients of runoff as shown in Table 5. Table 5: Post Development Catchment Impervious Properties 2 2 Catchment Impervious Area (m ) Catchment Area (m ) Fraction Impervious C10 A 3,220 3,578 0.90 0.88 B 1,292 1,436 0.90 0.88 With reference to QUDM Table 4.05.2, by applying the frequency factors for the standard storms of 2, 5, 10, 20, 50 and 100 years result in the following pre development coefficients of runoff as shown in Table 6. Table 6: Post Development Coefficients of Runoff Catchment 2 5 10 20 100 A&B 0.75 0.84 0.88 0.92 1.06 3.3.3 Time of Concentration Both post development catchments will have a standard time of concentration of five (5) minutes for paved areas. 3.3.4 Design Flow Rates Design storm flow rates have been calculated for standard storms with an ARI of 2, 5, 10, 20, 50 and 100 years for the post development case using design rainfall intensities from the Bureau of Meteorology. The Rational Method (Q = 2.78 x 10-3 CIA) has been used to calculate the required design flow rates for the subject site. The calculated post development peak flows for this subject site are presented in Table 7. Table 7: Catchment A - Post Development Peak Flow Rates Catchment A Average Recurrence ARI 2 5 10 20 100 Interval Coefficient of Runoff C 0.75 0.84 0.88 0.92 1.06 Average Rainfall Intensity I 164.1 201.6 223.0 252.6 320.6 (mm/h) Area of Catchment (ha) A 0.358 0.358 0.358 0.358 0.358 3 Peak Flow Rate (m /s) Q 0.122 0.168 0.195 0.232 0.337 Catchment B Average Recurrence ARI 2 5 10 20 100 Interval Coefficient of Runoff C 0.75 0.84 0.88 0.92 1.06 Average Rainfall Intensity I 164.1 201.6 223.0 252.6 320.6 (mm/h) Area of Catchment (ha) A 0.144 0.144 0.144 0.144 0.144 3 Peak Flow Rate (m /s) Q 0.049 0.067 0.078 0.093 0.135 K4277-0002-C 05 November 2018 Page 5 of 16
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.