Log in to see the plans as drawn TOW: 3.710 North Elevation
1 SCALE 1:50
EXISTING MASONRY WALL TOP: 4.680
TOS: 4.680
TOW: 3.710
TOW: 3.500
FSL: 2.000
TOW: 3.710
EXISTING MASONRY WALL
MIN 1% FALL INTO SUB-SURFACE CHANNEL DRAIN
TBM: 2.000 (ASSUMED)
MIN 1% FALL INTO SUB-SURFACE CHANNEL DRAIN
BENCH SEAT
TBM: 2000 ASSUMED
1000 DEEP (SOUTH END)
A/C A/C
FSL: 1.850 EXISTING DWELLING
POOL
PUMP FSL: 1.600
TOW: 3.740 FSL: 1.700
FSL: 1.850 1800 DEEP
TOS: 4.680
RL: 1.980 FSL: 1.700
TOP: 4.680
FSL: 1.830
LEGEND
RL: 1.700
P-TOP: 100.00 PROPOSED TOP OF SCREENING
TOW: 3.740 P-TOP: 100.00 PROPOSED TOP OF PERGOLA
RL: 1.550 TOW: 3.710
RL: 1.700 P-BOW: 100.00 PROPOSED BOTTOM OF WALL
P-TOW: 100.00 PROPOSED TOP OF WALL
FSL: 1.600
MIN 1% FALL TO PROPOSED PIT DRAIN 100.00 EXISTING SURVEY LEVELS
P-RL: 100.00 PROPOSED LEVELS
TO
TO
TO
W
W
:3
:3
W
:3
.5
.5
P-FFL: 100.00 PROPOSED FINISHED FLOOR LEVELS
00
00
.5
00
P-FSL: 100.00 PROPOSED FINISHED SURFACE LEVELS
100.00 SURVEY CONTOURS
MIN 1% FALL TO PROPOSED PIT DRAIN
For Development Application Only
-
APPROVED PLAN 0418 425 231
Revision Description Date By. Project Address: Sheet:
Scale: 1:75
1/15 Howard Street, Noosaville, QLD, 4566 L06 A
5987.2885.3 A.B.N. 45089234363
Suite 7/10 Thomas St,
NOOSA COUNCIL Noosaville, QLD, 4566 Client Name: Design:
[email protected] Nicole Tooth
27 JANUARY 2022 www.templeoutdoor.com.au
Proud member of:
Landscape Queensland Date: 9/6/21 Project No: 000109 Drawing Stage: For D.A.
AILDM
Noosa Property Hub
A INITIAL SUBMISSION 9/6/21 JB Council: Noosa Drawn By: JB Project Revision:
This design is covered by copyright & may not be reproduced without written permission from the author. The drawing refers to the overall design intent and may require structural engineers certification for construction elements. Intent of work is only shown and these drawings do not imply tactic approval for their structural integrity. No responsibility can be taken for construction, therefore any construction
© 2020 TEMPLE outdoor design & living works must be approved by an engineer and or a registered building certifier. TEMPLE Outdoor Design & Living recommends to use only licensed contractors. Check all measurements onsite prior to quatation or construction. Dial before you dig www.1100.com.au