SHOULD BE WELL PLANNED TO AVOID CONGESTION OF LOADING AREAS AND TRAINED TRAFFIC MANAGEMENT PERSONNEL
SHOULD BE USED TO SUPERVISE LOADING/UNLOADING AREAS. IF THIS BUILDING CONTAINS TIMBER FLOORS WHICH HAVE AN APPLIED FINISH. AREAS WHERE FINISHES ARE APPLIED SHOULD
BUSY CONSTRUCTION AND DEMOLITION SITES PRESENT A RISK OF COLLISION WHERE DELIVERIES AND OTHER TRAFFIC ARE BE KEPT WELL VENTILATED DURING SANDING AND APPLICATION AND FOR A PERIOD AFTER INSTALLATION. PERSONAL
MOVING WITHIN THE SITE. A TRAFFIC MANAGEMENT PLAN SUPERVISED BY TRAINED TRAFFIC MANAGEMENT PERSONNEL PROTECTIVE EQUIPMENT MAY ALSO BE REQUIRED. THE MANUFACTURER’S RECOMMENDATIONS FOR USE MUST BE CAREFULLY
W O R K P L A C E H E A L T H A N D S A F E T Y N O T I F I C A T I O N S: SHOULD BE ADOPTED FOR THE WORK SITE. CONSIDERED AT ALL TIMES.
1. FALLS, SLIPS, TRIPS 4. SERVICES 7. CONFINED SPACES
A) WORKING AT HEIGHTS DURING CONSTRUCTION RUPTURE OF SERVICES DURING EXCAVATION OR OTHER ACTIVITY CREATES A VARIETY OF RISKS INCLUDING RELEASE OF EXCAVATION
HAZARDOUS MATERIAL. EXISTING SERVICES ARE LOCATED ON OR AROUND THIS SITE. W H E R E K N O W N , THESE ARE IDENTIFIED
WHEREVER POSSIBLE, COMPONENTS FOR THIS BUILDING SHOULD BE PREFABRICATED OFF-SITE OR AT GROUND LEVEL TO ON THE PLANS BUT THE EXACT LOCATION AND EXTENT OF SERVICES MAY VARY FROM THAT INDICATED. SERVICES SHOULD BE CONSTRUCTION OF THIS BUILDING AND SOME MAINTENANCE ON THE BUILDING WILL REQUIRE EXCAVATION AND INSTALLATION
MINIMISE THE RISK OF WORKERS FALLING MORE THAN TWO METRES . HOWEVER, CONSTRUCTION OF THIS BUILDING WILL LOCATED USING AN APPROPRIATE SERVICE (SUCH AS DIAL BEFORE YOU DIG), APPROPRIATE EXCAVATION PRACTICE SHOULD BE OF ITEMS WITHIN EXCAVATIONS. WHERE PRACTICAL, INSTALLATION SHOULD BE CARRIED OUT USING METHODS WHICH DO NOT
REQUIRE WORKERS TO BE WORKING AT HEIGHTS WHERE A FALL IN EXCESS OF TWO METRES IS POSSIBLE AND INJURY IS LIKELY USED AND, WHERE NECESSARY, SPECIALIST CONTRACTORS SHOULD BE USED . REQUIRE WORKERS TO ENTER THE EXCAVATION. WHERE THIS IS NOT PRACTICAL, ADEQUATE SUPPORT FOR THE EXCAVATED
TO RESULT FROM SUCH A FALL. THE BUILDER SHOULD PROVIDE A SUITABLE BARRIER WHEREVER A PERSON IS REQUIRED TO UNDERGROUND POWER LINES ARE LOCATED IN OR AROUND THIS SITE. ALL UNDERGROUND POWER LINES MUST BE AREA SHOULD BE PROVIDED TO PREVENT COLLAPSE. WARNING SIGNS AND BARRIERS TO PREVENT ACCIDENTAL OR
WORK IN A SITUATION WHERE FALLING MORE THAN TWO METRES IS A POSSIBILITY. DISCONNECTED OR CAREFULLY LOCATED AND ADEQUATE WARNING SIGNS USED PRIOR TO ANY CONSTRUCTION , UNAUTHORISED ACCESS TO ALL EXCAVATIONS SHOULD BE PROVIDED .
MAINTENANCE OR DEMOLITION COMMENCING .
DURING OPERATION OR MAINTENANCE OVERHEAD POWER LINES ARE NEAR OR ON THIS SITE. THESE POSE A RISK OF ELECTROCUTION IF STRUCK OR APPROACHED ENCLOSED SPACES
BY LIFTING DEVICES OR OTHER PLANT AND PERSONS WORKING ABOVE GROUND LEVEL. WHERE THERE IS A DANGER OF THIS
(FOR HOUSES OR OTHER LOW -RISE BUILDINGS WHERE SCAFFOLDING IS APPROPRIATE) OCCURRING, POWER LINES SHOULD BE, WHERE PRACTICAL, DISCONNECTED OR RELOCATED. WHERE THIS IS NOT PRACTICAL ENCLOSED SPACES WITHIN THIS BUILDING MAY PRESENT A RISK TO PERSONS ENTERING FOR CONSTRUCTION , MAINTENANCE
ADEQUATE WARNING IN THE FORM OF BRIGHT COLOURED TAPE OR SIGNAGE SHOULD BE USED OR A PROTECTIVE BARRIER OR ANY OTHER PURPOSE. THE DESIGN DOCUMENTATION CALLS FOR WARNING SIGNS AND BARRIERS TO UNAUTHORISED
CLEANING AND MAINTENANCE OF WINDOWS , WALLS, ROOF OR OTHER COMPONENTS OF THIS BUILDING WILL REQUIRE PROVIDED. ACCESS. THESE SHOULD BE MAINTAINED THROUGHOUT THE LIFE OF THE BUILDING. WHERE WORKERS ARE REQUIRED TO
PERSONS TO BE SITUATED WHERE A FALL FROM A HEIGHT IN EXCESS OF TWO METRES IS POSSIBLE. WHERE THIS TYPE OF ENTER ENCLOSED SPACES, AIR TESTING EQUIPMENT AND PERSONAL PROTECTIVE EQUIPMENT SHOULD BE PROVIDED.
ACTIVITY IS REQUIRED , SCAFFOLDING, LADDERS OR TRESTLES SHOULD BE USED IN ACCORDANCE WITH RELEVANT CODES OF 5. MANUAL TASKS
PRACTICE, REGULATIONS OR LEGISLATION. SMALL SPACES
COMPONENTS WITHIN THIS DESIGN WITH A MASS IN EXCESS OF 25KG SHOULD BE LIFTED BY TWO OR MORE WORKERS OR BY
B) SLIPPERY OR UNEVEN SURFACES MECHANICAL LIFTING DEVICE. WHERE THIS IS NOT PRACTICAL, SUPPLIERS OR FABRICATORS SHOULD BE REQUIRED TO LIMIT SOME SMALL SPACES WITHIN THIS BUILDING WILL REQUIRE ACCESS BY CONSTRUCTION OR MAINTENANCE WORKERS .
THE COMPONENT MASS. THE DESIGN DOCUMENTATION CALLS FOR WARNING SIGNS AND BARRIERS TO UNAUTHORISED ACCESS . THESE SHOULD BE
FLOOR FINISHES ALL MATERIAL PACKAGING , BUILDING AND MAINTENANCE COMPONENTS SHOULD CLEARLY SHOW THE TOTAL MASS OF MAINTAINED THROUGHOUT THE LIFE OF THE BUILDING. WHERE WORKERS ARE REQUIRED TO ENTER SMALL SPACES THEY
PACKAGES AND WHERE PRACTICAL ALL ITEMS SHOULD BE STORED ON SITE IN A WAY WHICH MINIMISES BENDING BEFORE SHOULD BE SCHEDULED SO THAT ACCESS IS FOR SHORT PERIODS. MANUAL LIFTING AND OTHER MANUAL ACTIVITY SHOULD BE
THE OWNER IS RESPONSIBLE FOR THE SELECTION OF SURFACE FINISHES IN THE PEDESTRIAN TRAFFICABLE AREAS OF THIS LIFTING. ADVICE SHOULD BE PROVIDED ON SAFE LIFTING METHODS IN ALL AREAS WHERE LIFTING MAY OCCUR . RESTRICTED IN SMALL SPACES.
BUILDING. SURFACES SHOULD BE SELECTED IN ACCORDANCE WITH AS HB 197:1999 AND AS/NZ 4586:2004. CONSTRUCTION, MAINTENANCE AND DEMOLITION OF THIS BUILDING WILL REQUIRE THE USE OF PORTABLE TOOLS AND
EQUIPMENT. THESE SHOULD BE FULLY MAINTAINED IN ACCORDANCE WITH MANUFACTURER ’S SPECIFICATIONS AND NOT USED 8. PUBLIC ACCESS
STEPS, LOOSE OBJECTS AND UNEVEN SURFACES WHERE FAULTY OR (IN THE CASE OF ELECTRICAL EQUIPMENT ) NOT CARRYING A CURRENT ELECTRICAL SAFETY TAG. ALL
SAFETY GUARDS OR DEVICES SHOULD BE REGULARLY CHECKED AND PERSONAL PROTECTIVE EQUIPMENT SHOULD BE USED IN PUBLIC ACCESS TO CONSTRUCTION AND DEMOLITION SITES AND TO AREAS UNDER MAINTENANCE CAUSES RISK TO WORKERS
DUE TO DESIGN RESTRICTIONS FOR THIS BUILDING, STEPS AND/OR RAMPS ARE INCLUDED IN THE BUILDING WHICH MAY BE A ACCORDANCE WITH MANUFACTURER’S SPECIFICATION. AND PUBLIC. WARNING SIGNS AND SECURE BARRIERS TO UNAUTHORISED ACCESS SHOULD BE PROVIDED. WHERE ELECTRICAL
HAZARD TO WORKERS CARRYING OBJECTS OR OTHERWISE OCCUPIED. STEPS SHOULD BE CLEARLY MARKED WITH BOTH INSTALLATIONS, EXCAVATIONS, PLANT OR LOOSE MATERIALS ARE PRESENT THEY SHOULD BE SECURED WHEN NOT FULLY
VISUAL AND TACTILE WARNING DURING CONSTRUCTION , MAINTENANCE, DEMOLITION AND AT ALL TIMES WHEN THE BUILDING 6. HAZARDOUS SUBSTANCES SUPERVISED.
OPERATES AS A WORKPLACE .
BUILDING OWNERS AND OCCUPIERS SHOULD MONITOR THE PEDESTRIAN ACCESS WAYS AND IN PARTICULAR ACCESS TO AREAS ASBESTOS 9. OPERATIONAL USE OF BUILDING
WHERE MAINTENANCE IS ROUTINELY CARRIED OUT TO ENSURE THAT SURFACES HAVE NOT MOVED OR CRACKED SO THAT THEY IF THIS BUILDING WAS CONSTRUCTED PRIOR TO 1986 AND THEREFORE IS LIKELY TO CONTAIN A S B E S T O S EITHER IN CLADDING
BECOME UNEVEN AND PRESENT A TRIP HAZARD . SPILLS, LOOSE MATERIAL, STRAY OBJECTS OR ANY OTHER MATTER THAT MAY MATERIAL OR IN FIRE RETARDANT INSULATION MATERIAL. THE BUILDER SHOULD CHECK AND, IF NECESSARY , TAKE THIS BUILDING HAS BEEN DESIGNED AS A RESIDENTIAL BUILDING. IF IT, AT A LATER DATE, IS USED OR INTENDED TO BE USED AS
CAUSE A SLIP OR TRIP HAZARD SHOULD BE CLEANED OR REMOVED FROM ACCESS WAYS. APPROPRIATE ACTION BEFORE DEMOLISHING, CUTTING, SANDING, DRILLING OR OTHERWISE DISTURBING THE EXISTING A WORKPLACE , THE PROVISIONS OF THE WORK HEALTH AND SAFETY ACT 2011 OR SUBSEQUENT REPLACEMENT ACT SHOULD
CONTRACTORS SHOULD BE REQUIRED TO MAINTAIN A TIDY WORK SITE DURING CONSTRUCTION , MAINTENANCE OR STRUCTURE. BE APPLIED TO THE NEW USE.
DEMOLITION TO REDUCE THE RISK OF TRIPS AND FALLS IN THE WORKPLACE . MATERIALS FOR CONSTRUCTION OR
MAINTENANCE SHOULD BE STORED IN DESIGNATED AREAS AWAY FROM ACCESS WAYS AND WORK AREAS. POWDERED MATERIALS 10. OTHER HIGH RISK ACTIVITY
2. FALLING OBJECTS MANY MATERIALS USED IN THE CONSTRUCTION OF THIS BUILDING CAN CAUSE HARM IF INHALED IN POWDERED FORM . ALL ELECTRICAL WORK SHOULD BE CARRIED OUT IN ACCORDANCE WITH CODE OF PRACTICE: MANAGING ELECTRICAL RISKS AT
PERSONS WORKING ON OR IN THE BUILDING DURING CONSTRUCTION , OPERATIONAL MAINTENANCE OR DEMOLITION SHOULD THE WORKPLACE, AS/NZ 3012 AND ALL LICENSING REQUIREMENTS .
LOOSE MATERIALS OR SMALL OBJECTS ENSURE GOOD VENTILATION AND WEAR PERSONAL PROTECTIVE EQUIPMENT INCLUDING PROTECTION AGAINST INHALATION ALL WORK USING PLANT SHOULD BE CARRIED OUT IN ACCORDANCE WITH CODE OF PRACTICE: MANAGING RISKS OF PLANT AT
WHILE USING POWDERED MATERIAL OR WHEN SANDING, DRILLING, CUTTING OR OTHERWISE DISTURBING OR CREATING THE WORKPLACE.
CONSTRUCTION, MAINTENANCE OR DEMOLITION WORK ON OR AROUND THIS BUILDING IS LIKELY TO INVOLVE PERSONS POWDERED MATERIAL. ALL WORK SHOULD BE CARRIED OUT IN ACCORDANCE WITH CODE OF PRACTICE: MANAGING NOISE AND PREVENTING HEARING
WORKING ABOVE GROUND LEVEL OR ABOVE FLOOR LEVELS. WHERE THIS OCCURS ONE OR MORE OF THE FOLLOWING LOSS AT WORK .
MEASURES SHOULD BE TAKEN TO AVOID OBJECTS FALLING FROM THE AREA WHERE THE WORK IS BEING CARRIED OUT ONTO TREATED TIMBER DUE TO THE HISTORY OF SERIOUS INCIDENTS IT IS RECOMMENDED THAT PARTICULAR CARE BE EXERCISED WHEN
PERSONS BELOW . UNDERTAKING WORK INVOLVING STEEL CONSTRUCTION AND CONCRETE PLACEMENT . ALL THE ABOVE APPLIES.
1. PREVENT OR RESTRICT ACCESS TO AREAS BELOW WHERE THE WORK IS BEING CARRIED OUT . THE DESIGN OF THIS BUILDING INCLUDES PROVISION FOR THE INCLUSION OF TREATED TIMBER WITHIN THE STRUCTURE . DUST
2. PROVIDE TOE BOARDS TO SCAFFOLDING OR WORK PLATFORMS. OR FUMES FROM THIS MATERIAL CAN BE HARMFUL . PERSONS WORKING ON OR IN THE BUILDING DURING CONSTRUCTION , 11. P R E - C A S T & TILT - U P C O N S T R U C T I O N
3. PROVIDE PROTECTIVE STRUCTURE BELOW THE WORK AREA. OPERATIONAL MAINTENANCE OR DEMOLITION SHOULD ENSURE GOOD VENTILATION AND WEAR PERSONAL PROTECTIVE
4. ENSURE THAT ALL PERSONS BELOW THE WORK AREA HAVE PERSONAL PROTECTIVE EQUIPMENT . EQUIPMENT INCLUDING PROTECTION AGAINST INHALATION OF HARMFUL MATERIAL WHEN SANDING , DRILLING, CUTTING OR REFER TO THE NATIONAL CODE OF PRACTICE FOR PRE - CAST, TILT-UP AND CONCRETE ELEMENTS IN BUILDING CONSTRUCTION
USING TREATED TIMBER IN ANY WAY THAT MAY CAUSE HARMFUL MATERIAL TO BE RELEASED . DO NOT BURN TREATED TIMBER. (2008 OR LATEST EDITION) FOR EFFECTIVE RISK MANAGEMENT TO EMPLOYERS , EMPLOYEES ASSOCIATED WITH PRE-CAST &
BUILDING COMPONENTS TILT UP CONSTRUCTION .
VOLATILE ORGANIC COMPOUNDS
DURING CONSTRUCTION , RENOVATION OR DEMOLITION OF THIS BUILDING, PARTS OF THE STRUCTURE INCLUDING FABRICATED
STEELWORK, HEAVY PANELS AND MANY OTHER COMPONENTS WILL REMAIN STANDING PRIOR TO OR AFTER SUPPORTING
PARTS ARE IN PLACE . CONTRACTORS SHOULD ENSURE THAT TEMPORARY BRACING OR OTHER REQUIRED SUPPORT IS IN
MANY TYPES OF GLUE, SOLVENTS, SPRAY PACKS, PAINTS, VARNISHES AND SOME CLEANING MATERIALS AND DISINFECTANTS
HAVE DANGEROUS EMISSIONS. AREAS WHERE THESE ARE USED SHOULD BE KEPT WELL VENTILATED WHILE THE MATERIAL IS magica building design
PLACE AT ALL TIMES WHEN COLLAPSE WHICH MAY INJURE PERSONS IN THE AREA IS A POSSIBILITY. BEING USED AND FOR A PERIOD AFTER INSTALLATION. PERSONAL PROTECTIVE EQUIPMENT MAY ALSO BE REQUIRED. THE creative solutions
MECHANICAL LIFTING OF MATERIALS AND COMPONENTS DURING CONSTRUCTION , MAINTENANCE OR DEMOLITION PRESENTS A MANUFACTURER’S RECOMMENDATIONS FOR USE MUST BE CAREFULLY CONSIDERED AT ALL TIMES.
RISK OF FALLING OBJECTS . CONTRACTORS SHOULD ENSURE THAT APPROPRIATE LIFTING DEVICES ARE USED , THAT LOADS ARE
PROPERLY SECURED AND THAT ACCESS TO AREAS BELOW THE LOAD IS PREVENTED OR RESTRICTED. SYNTHETIC MINERAL FIBRE m . 0405 494 264
Carlo Magini c.s .e . - Building Designer.
3. TRAFFIC MANAGEMENT FIBREGLASS, ROCKWOOL, CERAMIC AND OTHER MATERIAL USED FOR THERMAL OR SOUND INSULATION MAY CONTAIN Lic. N o 1177987 - QBSA act 1991
SYNTHETIC MINERAL FIBRE WHICH MAY BE HARMFUL IF INHALED OR IF IT COMES IN CONTACT WITH THE SKIN , EYES OR OTHER e . [email protected] o m .a u
PARKING OF VEHICLES OR LOADING/UNLOADING OF VEHICLES ON THIS ROADWAY MAY CAUSE A TRAFFIC HAZARD . DURING SENSITIVE PARTS OR THE BODY . PERSONAL PROTECTIVE EQUIPMENT INCLUDING PROTECTION AGAINST INHALATION OF w. w w w .magicabuildingdesign.c o m .a u
HARMFUL MATERIAL SHOULD BE USED WHEN INSTALLING, REMOVING OR WORKING NEAR BULK INSULATION MATERIAL. PO Box 5859, Maroochydore BC. 4558
CONSTRUCTION, MAINTENANCE OR DEMOLITION OF THIS BUILDING DESIGNATED PARKING FOR WORKERS AND LOADING AREAS
SHOULD BE PROVIDED. TRAINED TRAFFIC MANAGEMENT PERSONNEL SHOULD BE RESPONSIBLE FOR THE SUPERVISION OF
THESE AREAS. TIMBER FLOORS
CLIENT STAGE
BUILDING APPROVAL
CONSTRUCTION OF THIS BUILDING WILL REQUIRE LOADING AND UNLOADING OF MATERIALS ON THE ROADWAY. DELIVERIES
SHOULD BE WELL PLANNED TO AVOID CONGESTION OF LOADING AREAS AND TRAINED TRAFFIC MANAGEMENT PERSONNEL IF THIS BUILDING CONTAINS TIMBER FLOORS WHICH HAVE AN APPLIED FINISH. AREAS WHERE FINISHES ARE APPLIED SHOULD A. AND D. KERR. BUILDING APPROVAL
BE KEPT WELL VENTILATED DURING SANDING AND APPLICATION AND FOR A PERIOD AFTER INSTALLATION. PERSONAL PROJECT ADDRESS
SHOULD BE USED TO SUPERVISE LOADING/UNLOADING AREAS.
BUSY CONSTRUCTION AND DEMOLITION SITES PRESENT A RISK OF COLLISION WHERE DELIVERIES AND OTHER TRAFFIC ARE PROTECTIVE EQUIPMENT MAY ALSO BE REQUIRED. THE MANUFACTURER’S RECOMMENDATIONS FOR USE MUST BE CAREFULLY 49 SEAVIEW TERRACE,, SUNSHINE BEACH , QLD.
MOVING WITHIN THE SITE. A TRAFFIC MANAGEMENT PLAN SUPERVISED BY TRAINED TRAFFIC MANAGEMENT PERSONNEL CONSIDERED AT ALL TIMES. SHEET TITLE
SHOULD BE ADOPTED FOR THE WORK SITE. WORKPLACE HEALTH AND SAFETY NOTES
7. CONFINED SPACES ORIGINAL SCALE SHT SIZE DRWN CHKD DATE
4. SERVICES
EXCAVATION
1:100 A3 C. M. C. M. 05 12 19
DRAWING No SHEET
19 - 013
ISSUE
RUPTURE OF SERVICES DURING EXCAVATION OR OTHER ACTIVITY CREATES A VARIETY OF RISKS INCLUDING RELEASE OF
HAZARDOUS MATERIAL. EXISTING SERVICES ARE LOCATED ON OR AROUND THIS SITE. W H E R E K N O W N , THESE ARE IDENTIFIED CONSTRUCTION OF THIS BUILDING AND SOME MAINTENANCE ON THE BUILDING WILL REQUIRE EXCAVATION AND INSTALLATION 11 of 11 C
ON THE PLANS BUT THE EXACT LOCATION AND EXTENT OF SERVICES MAY VARY FROM THAT INDICATED. SERVICES SHOULD BE OF ITEMS WITHIN EXCAVATIONS. WHERE PRACTICAL, INSTALLATION SHOULD BE CARRIED OUT USING METHODS WHICH DO NOT
LOCATED USING AN APPROPRIATE SERVICE (SUCH AS DIAL BEFORE YOU DIG), APPROPRIATE EXCAVATION PRACTICE SHOULD BE REQUIRE WORKERS TO ENTER THE EXCAVATION. WHERE THIS IS NOT PRACTICAL, ADEQUATE SUPPORT FOR THE EXCAVATED
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
19-013 - KERR RESIDENCE - 05 12 19.pdfRelated documentApplication case desk ↗
About this file
- File size
- 5.8 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.