Log in to see the plans as drawn raked ceiling section
beams to eng. design
colorbond roofing fixed selected cladding installed
roof trusses designed by truss manufacturer to man. spec. in accordance with man. spec.
and installed in accordance to man. spec.
roof trusses designed by truss manufacturer
and installed in accordance to man. spec.
9.0° 5.0°
flashing and capping installed
in accordance with man. spec.
5.0°
2.90
GF - CL (2700)
timber ceiling lining
GF - WL (2400)
f.c sheet to ext. ceilings
and eave lining colorbond gutter and fascia installed
in accordance with man. spec.
1.15
butlers
hall
alfresco pdr bed 3 portico
cellar
GF - FL (0) FFL xxx
10mm plasterboard lining
underslab and perimeter
reinforced concrete slab and footings to ceiling and walls
treatment to AS 3660.1
Section a to structural engineers details
1:100
colorbond roofing fixed
raked ceiling section beam to eng. details
to man. spec.
beams to eng. design
roof trusses designed by truss manufacturer roof trusses designed by truss manufacturer
and installed in accordance to man. spec. and installed in accordance to man. spec.
9.0°
10mm plasterboard lining 5.0°
to ceiling and walls
GF - CL (2700)
f.c sheet to ext. ceilings
and eave lining
living
bar
alfresco media
GF - FL (0) FFL xxx
ALFRESCO - FL (-50)
Section b underslab and perimeter
treatment to AS 3660.1
reinforced concrete slab and footings
to structural engineers details
1:100
raked ceiling section
roof trusses designed by truss manufacturer colorbond roofing fixed
beams to eng. design
and installed in accordance to man. spec. to man. spec.
raked ceiling section
beams to eng. design
colorbond gutter and fascia installed
in accordance with man. spec.
5.0°
GARAGE - CL (2700)
10mm plasterboard lining
f.c sheet to ext. ceilings to ceiling and walls
and eave lining
kitchen
hall garage
GF - FL (0) FFL xxx GF - FL (0)
underslab and perimeter
Section c reinforced concrete slab and footings
treatment to AS 3660.1
to structural engineers details
1:100
- © COPYRIGHT. THIS DRAWING REMAINS THE PROPERTY OF G.J GARDNER HOMES & IS PROVIDED FOR THE USE AS DESCRIBED & MAY NOT BE USED OR REPRODUCED IN WHOLE OR IN PART WITHOUT WRITTEN PERMISSION. ANY LANDSCAPING (WHEN SHOWN) ARE FOR ILLUSTRATIVE PURPOSES ONLY AND DO NOT FORM PART OF ANY CONTRACT.
APPROVED PLANS CLIENT: PROJECT ADDRESS: PROPOSED NEW RESIDENCE
PAGE: SHEET SIZE: REV DRN CHK DETAILS
8 A2
DATE: I/WE HAVE CHECKED THE PLANS AND AGREE THAT
THEY ACCURATELY DEPICT THE HOUSE FOR
CUSTOM
MM MM CONCEPT DRAWINGS FOR PRICING 25.01.21
MCU21/0086 Steven Turvey
6 & SP253957
JOB NUMBER: MM MM CONSTURCTION SET INC. AMENDS 26.03.21
CONSTRUCTION.
JOB SPECIFICATION BY BUILDER TAKES
Job Number
NOOSA COUNCIL
MM MM RFI AMENDS 15.04.21
PRECEDENCE OVER THESE PLANS.
GJ NOOSA PTY LTD DRAWING TITLE: 18 Yatama Plc, SALESPERSON:
28 JUNE 2021 QLD Chris Mcneil OWNER SIGNED: ............................... DATE: ..........
QLD Cooroibah
© COPYRIGHT EXCLUSIVE DATE: OWNER SIGNED: ............................... DATE: ..........
-
QBCC 1303975 QBCC 1257143
sections TO G.J.GARDNER HOMES Sections 15.04.21 BUILDER SIGNED: ............................. DATE: ..........