RFI - Arch plans with calcs and palette 1802_PARK_CRESCENT_ 30102020with calcs · MCU20/0073
Plans and drawings: the text below has words only, no drawings.
Par
kC
res
cen
t
sewer pump station
existing catch pit
5 x Ex-Ground Pandanus ov
138°2 erhead pow
3
designers
along frontage mixed with 9.867 '30"
er
coastal trees, shrubs and
grasses at various densities PO Box 262
and heights in accordance 146
°
with PSP2 5.30 19'30" Noosa Heads QLD 4567
5 Telstra pit
existing banksia Mobile 0419 758 478
28.00 16 [email protected]
5.3 2°12 power pole
mix of fraser island 05 '00
" and light
apples and lilly pilly 2m setback www.kiddco.com.au
screening species for pools QBCC
along boundary
(0.75m wide garden This drawing is to be read in
bed with 25L trees conjunction with Engineers Drawings &
17 05
5.3
8°
planted with 1m Reports
04
23.66 0"
spacing)
'00
'3
48°23
7
"
top of pool
1m above
29.00
finished
ground
level Construction to comply
with all relevant SAA &
BCA Codes & standard
Bldg By-law 1975 & as
amended
Verify all dimensions on
186 88
site prior to commencement
15.
°00
of any works. These
0
'00"
30.00 drawings are not to be
used for scaling
Copyright for design &
fire hydrant drawings remain the
property of the authors.
ove
rhe
ad p
27.50
owe
203°00'1
5.936
r
0"
28.00
30.00
top of pool
3m Setback 1m above
finished 28.50
ground
9m setback
5.93 00'30"
level
19°00
23.66
power pole
°
6
237
'00"
7
and light
6m setback
Driveway
existing pandanas
direction
50" 28.50 palms to be retained
to engineers detail2m setback
1 °00'
29.50 27 36
for pools 5.9
existing banksia
28.00
0'00"
289°0
94
23.0
28.00
power pole
28.50 and light
ower
29.00 ead p
water meter overh
existing banksia
existing catch pit
Telstra pit
rescent
Park C
Landscape Area = 650m2 (58%)
1. SITE PLAN
SD.101 SCALE1:200
REAL PROPERTY DESCRIPTION Project
Lot: Proposed 4 Units
Parish:
Location
Address: 15&13 Park Crescent
15&13 Park Crescent
Sunshine Beach QLD 4567
Sunshine Beach
Site Area: 1121m2 Client
Mark Bain
Drawing Title
SITE PLAN
Scale Date
as shown @A3 Sept 20
Drawn By Job No:
JLK 1802
Drawing No. Issue No.
SD.101 B
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 14 pages
Page 2
designers PO Box 262 Noosa Heads QLD 4567 Telephone 07 5447 5633 Mobile 0419 758 478 [email protected] www.kiddco.com.au This drawing is to be read in conjunction with Engineers Drawings & Reports Construction to comply with all relevant SAA & BCA Codes & standard Bldg By-law 1975 & as amended Verify all dimensions on site prior to commencement of any works. These drawings are not to be used for scaling Copyright for design & drawings remain the property of the authors. Project Proposed 4 Units Location 15&13 Park Crescent Sunshine Beach Client Mark Bain Drawing Title PERSPECTIVES Scale Date as shown @A3 Feb 19 Drawn By Job No: JLK 1802 Drawing No. Issue No. SD.102 B
Page 3
designers PO Box 262 Noosa Heads QLD 4567 Telephone 07 5447 5633 Mobile 0419 758 478 [email protected] www.kiddco.com.au This drawing is to be read in conjunction with Engineers Drawings & Reports Construction to comply with all relevant SAA & BCA Codes & standard Bldg By-law 1975 & as amended Verify all dimensions on site prior to commencement of any works. These drawings are not to be used for scaling Copyright for design & drawings remain the property of the authors. Project Proposed 4 Units Location 15&13 Park Crescent Sunshine Beach Client Mark Bain Drawing Title PERSPECTIVES Scale Date as shown @A3 Feb 19 Drawn By Job No: JLK 1802 Drawing No. Issue No. SD.103 B
Page 4
designers
PO Box 262
Noosa Heads QLD 4567
External Doors and windows to be white powder Telephone 07 5447 5633
coated aluminium framed with clear glazing infill Mobile 0419 758 478
[email protected]
www.kiddco.com.au
This drawing is to be read in
conjunction with Engineers Drawings &
White Powdercoated aluminum and glass Reports
balustrade
Construction to comply
with all relevant SAA &
Flyover roof with powder coated aluminium sun BCA Codes & standard
Bldg By-law 1975 & as
control battens amended
Verify all dimensions on
site prior to commencement
of any works. These
drawings are not to be
used for scaling
Copyright for design &
drawings remain the
property of the authors.
Project
Proposed 4 Units
Location
15&13 Park Crescent
Sunshine Beach
Client
Mark Bain
Drawing Title
Rendered block wall with horizontal expressed MATERIALITY PALLET
joints to be warm white
Scale Date
as shown @A3 Feb 19
Drawn By Job No:
Travertine stone tiled balconies JLK 1802
Drawing No. Issue No.
SD.104 B
Page 5
designers
PO Box 262
Noosa Heads QLD 4567
Telephone 07 5447 5633
Mobile 0419 758 478
[email protected]
www.kiddco.com.au
This drawing is to be read in
conjunction with Engineers Drawings &
Reports
Construction to comply
with all relevant SAA &
BCA Codes & standard
Bldg By-law 1975 & as
amended
Verify all dimensions on
site prior to commencement
of any works. These
drawings are not to be
used for scaling
Copyright for design &
drawings remain the
property of the authors.
Project
Proposed 4 Units
Location
15&13 Park Crescent
Sunshine Beach
3D 12m HEIGHT LIMIT Client
SD.105 SCALE1:100 Mark Bain
Drawing Title
HEIGHT LIMIT
Scale Date
as shown @A3 Feb 19
Drawn By Job No:
JLK 1802
Drawing No. Issue No.
SD.105 B
Page 6
designers
Landscaped Retaining wall,
Refer to Civil engineering for PO Box 262
Noosa Heads QLD 4567
details and specification
line Mobile 0419 758 478
of dec
k ov [email protected]
Storage er
www.kiddco.com.au
QBCC
This drawing is to be read in
line of building over conjunction with Engineers Drawings &
Reports
Garage 1
RL 26.500 lin
eo
fb
uil Construction to comply
din
g ov with all relevant SAA &
er BCA Codes & standard
Bldg By-law 1975 & as
amended
Verify all dimensions on
site prior to commencement
of any works. These
Store drawings are not to be
used for scaling
RL 26.500 Copyright for design &
drawings remain the
property of the authors.
Garage 2
RL 26.500
Store
6m Setback
RL 26.500
Storage
Visitor Parking 1
RL 26.500
UP
4
3
2
1
16
Fire
5
6
15
14 Lobby Driveway
7
Stair RL 27.500
Lift
13
8
10
12
11
9
Visitor Parking 2
RL 26.500
Storage
Garage 3 Store
RL 26.500 RL 26.500
Bin
ver
Store
ck oe
RL 26.500
of d
line
3m Setback
er
g ov
din
buil
f
eo
lin
Garage 4
RL 26.500
Project
line of building over 6m Setback Proposed 4 Units
Location
15&13 Park Crescent
Storage Sunshine Beach
Client
Mark Bain
er
line of deck ov Drawing Title
BASEMENT PLAN
Landscaped Retaining wall,
Refer to Civil engineering for Scale Date
as shown @A3 Sept 20
details and specification
Drawn By Job No:
1. BASEMENT JLK 1802
SD.201 SCALE1:100 Drawing No. Issue No.
SD.201 B
Page 7
B
designers
PO Box 262
Noosa Heads QLD 4567
Mobile 0419 758 478
[email protected]
www.kiddco.com.au
Deck QBCC
This drawing is to be read in
conjunction with Engineers Drawings &
Reports
Shr Deck
L Pool
Bed 1 Construction to comply
Ens 2 with all relevant SAA &
BCA Codes & standard
L Bldg By-law 1975 & as
Bed 2 amended
Verify all dimensions on
WC L site prior to commencement
robe of any works. These
drawings are not to be
Niche used for scaling
Copyright for design &
Ens 1 Shr drawings remain the
robe property of the authors.
L
F
Laundry Living
robe
Deck
Bed 3
Kitchen
Ens 3 Study
RL 29.150
7
6
5
4
3
2
1
Dining
DN
UP
L
UP
5
4
3
2
1
19
6
7
Fire 18
17
Lobby
8
Stair 16
9 15
Lift RL 29.150 BBQ
10
12
13
14
11
L
Dining DN
UP
Kitchen
7
6
5
4
3
2
1
Ens 3 Study RL 29.150
Bed 3
robe
Deck
Laundry Living
L
F
robe
Ens 1 Shr
Niche
robe
WC WC L
Pool
Bed 2
L
3m Setback
Ens 2
Bed 1
L
Shr
Project
Proposed 4 Units
Location
Deck 15&13 Park Crescent
6m Setback Sunshine Beach
Roof over Client
Mark Bain
Drawing Title
GROUND FLOOR
PLAN
Scale Date
L1 Site Cover = 340m2 (30%) as shown @A3 Sept 20
L1 Gross Floor Area = 322m2
Drawn By Job No:
2. GROUND FLOOR JLK
Drawing No.
1802
Issue No.
SD.202 SCALE1:100
SD.202 B
Page 8
designers
PO Box 262
Noosa Heads QLD 4567
Mobile 0419 758 478
[email protected]
www.kiddco.com.au
QBCC
This drawing is to be read in
conjunction with Engineers Drawings &
Reports
Pool
Deck
Construction to comply
with all relevant SAA &
BCA Codes & standard
Bldg By-law 1975 & as
amended
DW
Verify all dimensions on
site prior to commencement
L of any works. These
drawings are not to be
used for scaling
Copyright for design &
Kitchen L drawings remain the
RL 36.350 Living property of the authors.
F
Laundry
Dining
L
L
DN
L
Fire Deck
Stair RL 36.350
Lift
Bed 1
Study
Linen Ens 2
robe
L
robe
Ens 3 C
L
Bed 2
Bed 3
L
3m Setback L
10m setback
9m setback
Project
Proposed 4 Units
Location
6m setback
15&13 Park Crescent
Sunshine Beach
Client
Mark Bain
Drawing Title
SECOND FLOOR
Scale Date
L2 Site Cover = 296m2 (26%) as shown @A3 Sept 20
L2 Gross Floor Area = 185m2
Drawn By Job No:
4. SECOND FLOOR JLK
Drawing No.
1802
Issue No.
SD.204 SCALE1:100
SD.204 B
Page 9
designers
PO Box 262
Noosa Heads QLD 4567
Mobile 0419 758 478
[email protected]
www.kiddco.com.au
QBCC
This drawing is to be read in
conjunction with Engineers Drawings &
Reports
Pool
Deck
Construction to comply
with all relevant SAA &
BCA Codes & standard
Bldg By-law 1975 & as
amended
DW
Verify all dimensions on
site prior to commencement
L of any works. These
drawings are not to be
used for scaling
Copyright for design &
Kitchen L drawings remain the
RL 32.650 Living property of the authors.
F
Laundry
Dining
W/C L
L
UP
L
5
4
3
2
1
Ens 1
20
Fire
6
19
Deck
7
18
Stair
8
17
RL 32.650
9
Lift
16
10
12
13
14
15
11
Bed 1
Study
Linen Ens 2
robe
L
robe
Ens 3 C
L
Bed 2
Bed 3
L
3m Setback L
10m setback
9m setback
Deck
Project
Proposed 4 Units
Location
6m setback
15&13 Park Crescent
Sunshine Beach
Client
Mark Bain
Drawing Title
FIRST FLOOR PLAN
Scale Date
L3 Site Cover = 296m2 (26%) as shown @A3 Sept 20
L3 Gross Floor Area = 180m2
Drawn By Job No:
3. FIRST FLOOR JLK
Drawing No.
1802
Issue No.
SD.203 SCALE1:100
SD.203 B
Page 10
designers
PO Box 262
Noosa Heads QLD 4567
Telephone 07 5447 5633
Metal Roof
Mobile 0419 758 478
[email protected]
Metal Awning www.kiddco.com.au
This drawing is to be read in
Powder Coated Aluminium conjunction with Engineers Drawings &
Framed Windows Reports
Construction to comply
with all relevant SAA &
Pastel Paint Finish to BCA Codes & standard
Rendered Block Wall Bldg By-law 1975 & as
amended
Powder Coated Aluminium Verify all dimensions on
Framed Balustrade 1.2m High site prior to commencement
of any works. These
Powder Coated Framed drawings are not to be
Aluminium Louvers used for scaling
Copyright for design &
drawings remain the
Powder Coated Aluminium property of the authors.
Framed Bifold Doors
Top of pool 1m above
finished ground level
Project
Proposed 4 Units
Location
15&13 Park Crescent
Sunshine Beach
NORTH ELEVATION Client
Mark Bain
SD.501 SCALE1:100 Drawing Title
NORTH ELEVATION
Scale Date
as shown @A3 Feb 19
Drawn By Job No:
JLK 1802
Drawing No. Issue No.
SD.501 B
Page 11
designers
PO Box 262
Noosa Heads QLD 4567
Metal Roof Telephone 07 5447 5633
Mobile 0419 758 478
Powder Coated Aluminium [email protected]
Framed Bifold Doors
www.kiddco.com.au
This drawing is to be read in
conjunction with Engineers Drawings &
Powder Coated Framed Reports
Aluminium Louvers
Construction to comply
Powder Coated Aluminium with all relevant SAA &
Framed Balustrade 1.2m High BCA Codes & standard
Bldg By-law 1975 & as
amended
Pastel Paint Finish to Verify all dimensions on
Rendered Block Wall site prior to commencement
of any works. These
drawings are not to be
Powder Coated Aluminium
used for scaling
Framed Windows
Copyright for design &
drawings remain the
Top of pool 1m above property of the authors.
finished ground level
Project
Proposed 4 Units
Location
15&13 Park Crescent
Sunshine Beach
EAST ELEVATION Client
Mark Bain
SD.502 SCALE1:100 Drawing Title
EAST ELEVATION
Scale Date
as shown @A3 Feb 19
Drawn By Job No:
JLK 1802
Drawing No. Issue No.
SD.502 B
Page 12
designers
PO Box 262
Noosa Heads QLD 4567
Telephone 07 5447 5633
Mobile 0419 758 478
[email protected]
Metal Roof
www.kiddco.com.au
Metal Awning
This drawing is to be read in
conjunction with Engineers Drawings &
Powder Coated Framed Reports
Aluminium Louvers
Construction to comply
Powder Coated Aluminium with all relevant SAA &
Framed Balustrade 1.2m High BCA Codes & standard
Bldg By-law 1975 & as
amended
Verify all dimensions on
Metal Awning site prior to commencement
of any works. These
Powder Coated Aluminium
drawings are not to be
Framed Bifold Doors
used for scaling
Powder Coated Aluminium Copyright for design &
Framed Windows drawings remain the
property of the authors.
Top of pool 1m above
finished ground level
Project
Proposed 4 Units
Location
15&13 Park Crescent
Sunshine Beach
SOUTH ELEVATION Client
Mark Bain
SD.503 SCALE1:100 Drawing Title
SOUTH ELEVATION
Scale Date
as shown @A3 Feb 19
Drawn By Job No:
JLK 1802
Drawing No. Issue No.
SD.503 B
Page 13
designers
PO Box 262
Noosa Heads QLD 4567
Telephone 07 5447 5633
Mobile 0419 758 478
Metal Roof
[email protected]
www.kiddco.com.au
Metal Awning This drawing is to be read in
conjunction with Engineers Drawings &
Powder Coated Aluminium Reports
Framed Windows
Construction to comply
Pastel Paint Finish to with all relevant SAA &
Rendered Block Wall BCA Codes & standard
Bldg By-law 1975 & as
amended
Verify all dimensions on
Powder Coated Aluminium
site prior to commencement
Framed Balustrade 1.2m High
of any works. These
drawings are not to be
Powder Coated Aluminium used for scaling
Framed Bifold Doors Copyright for design &
drawings remain the
Fire door property of the authors.
Project
Proposed 4 Units
Line of Building Location
15&13 Park Crescent
Sunshine Beach
Client
Mark Bain
Drawing Title
WEST ELEVATION WEST ELEVATION
SD.504 SCALE1:100 Scale Date
as shown @A3 Feb 19
Drawn By Job No:
JLK 1802
Drawing No. Issue No.
SD.504 B
Page 14
designers
Boundary line
Fall 12m height limit PO Box 262
Noosa Heads QLD 4567
40,050 Roof RL
Telephone 07 5447 5633
Mobile 0419 758 478
39,800 Second Floor Ceiling RL
[email protected]
3,700
www.kiddco.com.au
3,450
This drawing is to be read in
conjunction with Engineers Drawings &
Reports
36,350 Second Floor RL
Construction to comply
with all relevant SAA &
250
36,100 First Floor Ceiling RL BCA Codes & standard
Bldg By-law 1975 & as
amended
3,700
Verify all dimensions on
3,450
site prior to commencement
of any works. These
drawings are not to be
used for scaling
Copyright for design &
32,650 First Floor RL
drawings remain the
property of the authors.
250
32,400 Ground Floor Ceiling RL
3,500
3,250
29,150 Ground Floor RL
866
250
28,900 Basement Ceiling RL NGL
2,650
2,400
26,500 Basement RL Project
Proposed 4 Units
250
Location
15&13 Park Crescent
A Sunshine Beach
Client
SD.601 SCALE1:100
Mark Bain
Drawing Title
SECTION A
Scale Date
as shown @A3 Feb 19
Drawn By Job No:
JLK 1802
Drawing No. Issue No.
SD.601 B
Page 15
designers
12 Height
PO Box 262
Noosa Heads QLD 4567
40,050 Roof RL
Telephone 07 5447 5633
Mobile 0419 758 478
39,800 Second Floor Ceiling RL
[email protected]
3,700
www.kiddco.com.au
This drawing is to be read in
conjunction with Engineers Drawings &
Reports
36,350 Second Floor RL
Construction to comply
with all relevant SAA &
36,100 First Floor Ceiling RL BCA Codes & standard
Bldg By-law 1975 & as
amended
3,700
Verify all dimensions on
site prior to commencement
of any works. These
drawings are not to be
used for scaling
Copyright for design &
32,650 First Floor RL
drawings remain the
property of the authors.
32,400 Ground Floor Ceiling RL
3,500
29,150 Ground Floor RL
937
28,900 Basement Ceiling RL NGL
2,650
26,500 (Basement) Project
Proposed 4 Units
Location
15&13 Park Crescent
B Sunshine Beach
Client
SD.602 SCALE1:100
Mark Bain
Drawing Title
SECTION B
Scale Date
as shown @A3 Feb 19
Drawn By Job No:
JLK 1802
Drawing No. Issue No.
SD.602 B