Original source · versioned page text
Skale plans
Attached to the e-mail Application and Design plans.
The original of this document is very large (12.1 MB). Opening the original or downloading it may take a few minutes. Please be patient and don't click again. The page text is quick to read. If you are on mobile data, it is best to wait until you are on Wi-Fi.
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawn¿ play your part - print on recycled paper 5m 4 3 2 1
PLAN LEGEND
a/c air conditioning unit
b basin
bin waste disposal bin
bbq barbeque
bth bath
cm coffee maker
con concrete
dry clothes dryer
dw dishwasher
dwn down stair direction
dp down pipe
eg eave gutter
fw floor waste
ofs overflow spitter
pty pantry
ref refrigerator
rh range hood
rwh rain water head
rwo rain water outlet
s sink
swg stormwater grate/pit
shr shower Timber framed hwd stairs with open risers. Stairs to comply with NCC 3.9.1.
shs steel post A B
t laundry tub 100 x 16mm H4 treated hwd paling undercroft screening with H4 treated hwd
up up stair direction posts and rails. Screening to have palings spaced with 75mm gap and palings
wc toilet suite to each side of rails offset. Undercroft are to have full perimeter screening.
wm washing machine
wo wall oven
C D E F G
3x Bushmans T6500 (30 000L) water tank to be semi in ground max. depth 750mm. tank to have C D E
washed river sandbase and compacted with a plate compactor, to provide a firm level base. Tank
3 600 7 700 1 900 10 470 3 090 5 320
to be installed in accordance with tank manufacturers specifications.
1800mm high Colorbond fencing 1800mm high Colorbond fencing 1800mm high Colorbond fencing
1 8 7 6 5 4 3 2 1
1
800
800
2 2
1200mm high Aluminium fencing
100 x 16mm H4 treated hwd paling undercroft screening with H4 treated hwd
posts and rails. Screening to have palings spaced with 75mm gap and palings
to each side of rails offset.
6 300
6 300
Undercroft
A Bushmans T6500 A
Timber framed decking stairs to have h4 treated timber structure in accordance (30 000L) water tank
with structural engineers design and detail. Provide 86 x 19mm spotted gum Concrete driveway to be in accordance structural
decking (Standard & Better Grade) with Buildex® Dec-King® stainless steel self engineers design and detail. Driveway to comply with
drilling decking screws to structure. Decking shall be installed in accordance AS2890.1. Provide new crossover in accordance with
with Timber Queensland Technical Data Sheet 13. Stairs to be in accordance local authority regulations. Driveway grades to be in
with NCC 3.9.1. Provide spotted gum 50mm Handrail to have selected 316 accordance with AS2890.1. Driveway to be in selected
stainless steel offset brackets, handrail to comply with NCC 3.9.1. exposed aggregate concrete with tool joints as detailed,
Bushmans T6500 provide slip resistant clear sealer coat to entire driveway,
3 (30 000L) water tank applied in accordance with manufacturers specifications. 3
Store 7 - T6500 (29560 litres)
1 200
1 200
Concrete
1200mm high Aluminium fencing
4 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
4
2 300
2 300
Bushmans T6500
(30 000L) water tank
7 - T6500 (29560 litres)
5 5
2x battened gates hot dip
1200mm high Aluminium fencing galv. shs frame 7 - T6500 (29560 litres)
5 690
5 690
2x battened gates hot dip
2x battened gates hot dip
galv. shs frame
galv. shs frame
Boat store
Concrete
B B
6 6
290mm Concrete block wall to be in accordance with structural engineers design and detail. Top
Aluminium fencing
1200mm high
course of block wall Lintel blocks unfilled as planter bed. Provide Rockcote acrylic render system
with sponge finish and painted with selected colour in accordance with final colour selections to
exposed wall surfaces. Refer to Rockcote for full coating system details. Planter to have 2x
40mm upvc drainage outlets and Emer-Proof Ecoflex Anti Root waterproofing system.
A B
190mm Concrete block wall to be in accordance with structural engineers design and detail.
Provide Rockcote acrylic render system with sponge finish and painted with selected colour in
accordance with final colour selections to exposed external wall surfaces (undercroft & inside 3 600
C 7 700 1 900
D 10 470
E 3 090 5 320
boat store area ironed joins and painted finish only). Refer to Rockcote for full coating system
details.
C D E F G
Floor plan - Sub floor
1:100
/Users/benthornton/Docs/Cadfiles/1901 - Seeto/Archicad/23072020/1901.pln
sbt designs pty ltd t/a
Skale Building Design builder Chris Fletcher
Director / Builder
project Residence lot no. 9 H Revised Construction issue 20/8/20
project number
Mobile: 0412 025 657 Squire Development Group Pty Ltd
for Dereke & Melanie Seeto plan no. 99140 G Revised Construction issue 23/7/20
1901
skale
0412 743 408 F Revised Construction issue 9/7/20
skale.com.au 71 Noosa River Drive drawn BT
E Revised BA issue 29/6/20
drawing number
building design
[email protected]
A.C.N. 123 976 296 QBCC: 1143 609 at Noosa North Shore scale (A2) 1:100 Rev Details Date 1.2 H © Skale Building Design
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalVery large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.