Skip to the record
Every meeting, every word.

Council archive · source document

Response to Information Request · OPW11/0281

of 7

Text shows just the words. Original shows the document exactly as it was published.

     NOTES.
     1. THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITH ALL OTHER CONSULTANTS
     DRAWINGS AND SPECIFICATIONS.
                                                                                                                                                                                                                                                                                                                             S
     2. BEFORE PROCEEDING WITH THE WORK ANY DISCREPANCIES IN THE CONTRACT
     DOCUMENTS SHALL BE REFERRED FOR DECISION TO THE ENGINEER.
     3. 00 NOT SCALE FROM DRAWINGS IF IN DOUBT. ASKS                                                                                                                                                                                                                                                                            t
     4. CONTRACTOR SHALL VERIFY ALL LOCATIONS OF SERVICES. ALL DIMENSIONS AND
     LEVELS PRIOR TO CONSTRUCTION.
     5. ALL MATERIALS & WORKMANSHIP SHALL BE IN ACCORDANCE WITH AS2890, THE
     BUILDING CODE OF AUSTRALIA (INCLUDING THE QUEENSLAND SUPPLEMENT(. THE
     QUEENSLAND BUILDING ACT AMENDMENT ACT 1991 AND THE LOCAL AUTHORITY'S
     BY-LAWS.
     S. THE CONTRACTOR IS RESPONSIBLE TO OBTAIN RELEVANT APPROVALS PRIOR TO
     COMMENCEMENT OF WORKS.
     6. ALL STORMWATER CULVERTS TO BE RCP CLASS 2. ALL ROOFWATER PIPES TO BE
     uPVC CLASS '5H'.
     7. SILT MANAGEMENT PLAN TO REMAIN IN PLACE UNTIL COMPLETION OF WORKS AND
     SATISFACTORY MAINTENANCE IS COMPLETED.
     8. ALL PROPOSED OPERATIONAL WORKS SHALL BE CONSTRUCTED IN ACCORDANCE
     WITH COUNCIL'S OPERATIONAL WORKS APPROVAL LETTER AND COUNCIL'S DECISION
     NOTICE-DEVELOPMENT PERMIT.
     9. CONCRETE KERB RAMPS SHALL BE ALIGNED TO COMPLY WITH COUNCIL'S STANDARD                                                                                                                                                                                                                                                      m
     DRAWING AND SHALL BE CONSTRUCTED STRICTLY IN ACCORDANCE WITH
                                                                                                                                                                                                                                                                                                                                    oar
                                                                                                                                                                                                                                                                                                                            I-
     COUNCIL STANDARD DRAWING.                                                                                                                                                                                                                                                                                              J             0
     10. ALL TEMPORARY & PERMANENT ROAD SIGNS AND LINEMARKING SHALL COMPLY WITH                                                                                                                                                                                                                                                     N
                                                                                                                                                                                                                                                                                                                                    0
     THE CURRENT MANUAL OF UNIFORM TRAFFIC CONTROL DEVICESIM.U.T.C.0.1. EXISTING LINE                                                                                                                                                                                                                                               Z
     MARKING SHALL BE REMOVED BY GRINDING NOT"BLACKING OUT. COUNCIL DOES NOT
     APPROVE OF BLACKING OUT OF EXISTING LINE MARKING.



            SEWERAGE NOTES
1. Where ductile iron pipe is specified it                                                                                                                                                                                                                                                                                          -,a
   shall be class K9 heavy cement lined.
2. Where sewers are laid in fill, such fill
   shall be compacted 95% standard A.A.S.H.O.
   in maximum layers of 150mm. Proof of
   compaction is to be submitted to the
   superintendant.
3. House connection branches to be installed
   in accordance with COUNCIL Standard Drawings.

4. Work on existing sewers to be carried out
   by COUNCIL at developers cost.                                                                                                                           NOTES:
5. Drops to be external in D.I.C.L. or PVC.                                                                                                                 1. Crossings are not designed for commercial vehicles.
                                                                                                                                                            2. Footpath section to vary where necessary to match concrete footpaths and
6. Sewers to be laid in accordance with COUNCIL                                                                                                                verge profiles. Footpath earthworks adjoining concrete must be well compacted
   Guidelines, bedding type A unless                                                                                                                        3. Concrete surface tolerances to be +Smm/-Omm over 3 metre section
   otherwise instructed.                                                                                                                                    4. Concrete N25 in accordance with AS 1379, and AS 3600
 7. Min. clear cover to be as per Table 4.8                                                                                                                 5. Reinforced fabric to AS 1304,50 lop and edge cover, lop fabric 250mm
    of WSA02.                                                                                                                                               6. Approved materials for construction:- Concrete, paving blocks or asphalt
                                                                                                                                                            7. Expansion joints to be 10mm wide, full depth closed cell cross linked                                                                                        a
                                                                                                                                                                                                                                                                                                                            0
8.   Sewers constructed at grades greater than                                                                                                                 polyethylene foam (85 - 150 kg/m sq) or compressed granulated corkboard,
     1 in 6 shall be provided with concrete stops                                                                                                              installation to manufacturers' specifications.
     in accordance with Council's guidelines                                                                                                                8. All appropriate permits must be obtained from council, including approval
                                                                                                                                                               of location and levels prior to excavation.
9. Preferred sewer alignment is 1.5m from front
   and rear boundaries, and 1m from side boundary.                                                                                                          9. Refer protect drawings of local authourity standard drawings for verge
                                                                                                                                                               type cross sections.
10. Manhole covers shall be 600mm clear opening ductile                                                                                                    10. One access point to be constructed to each lot as per standard drawing.
    iron covers and cast iron frames and be 75mm above                                                                                                     It. Earthworks cut and lit batters from edge of driveway to natural surface
    finished surface level as per WSA02 Std Dwg No. SEW-1308.                                                                                                  to be max. grade at 1 in 10 and fully turfed.
                                                                                                                                                           12. Driveways must ocheive a high point of 250mm obove invert of kerb to ensure
11. House connections in adjoining properties to the sewer                                                                                                     stormwater is contained within rood reserve as per requirement of QUDM.                                                                                      V
    line shall extend 1.5m into the property being served.                                                                                                                                                                                                                           BARRIER, SEMI - MOUNTABLE OR           Cr
                                                                                                                                                                This constraint may be varied upon the approval of local authority.                                                                                         0
                                                                                                                                                           13. Existing footpath to be transitional to new driveway at a max grade of 1 in 10.                                       MOUNTABLE KERB & CHANNEL BREAKOUT
12. All house connections joining to sewers deeper than
                                                                                                                                                           14. Under special circumstances Council may approve a rising grade of 1 in 8 in
    2.1m are to use sugden fittings.

13. Installation of detectable marker tape for all non-metallic sewer
                                                                                                                                                               this location or Within Im of the property boundary,
                                                                                                                                                           15. All dimensions are in millimetres, unless noted otherwise.
                                                                                                                                                                                                                                                                                     CROSSOVER DETAIL
     mains is required in accordance with Council's requirements.




                                                                                                                                                                                                                                                                                                                                              N

                                                                                                                                                                                                                                                                                                     r    Kam   H   1   i

                                                                                              Pavement Level Location

                                                                                                                     Bolster cut slob (3w x 30d)
                                                                                                                     Fill joint to 3mm. below surface
                                                                                                                     with Fosroc Expandite Thioflex 600g
                                                                                                                     or similar,




                                                                                   NOTE
                                                                                                                             Cut every second wire
                                                                                   SAW (VT5 FUSING A SOFT (UT SAW( SHALL
                                                                                   BE INSTALLED WITHIN B HOURS OF CONCRETE   directly under joint and
                                                                                                                                                                                                                                                 FOR NFOMA1aN NOT SHOWN REFER NFJwe COAST RECO)W SNAE OOUra,
                                                                                   RLACENENT IWMEN AVERAGE AMBIENT           depress fabric locally.                                                                                             Shin S,*N Ds»oo
                                                                                   rEMVERAIVRE EXCEEDS 32- ENS Iww                                                                                                                               Eviq, & Smxy Smrus Wit 0-wig Mxr&w 40 R-0050 MARCH 2008
                                                                                   SHALL BE REDUCED TO 4 HOUR 1.



                                                                                                            SAW CUT - (SCI                                                                                                                                              TYPICAL PROFILE DRIVEWAY ACCESS

Used in these records

About this file

File size
1.9 MB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Response to Information Request.pdf · 1.9 MB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.