3.0 Conclusions and Recommendations
As noted above we have demonstrated that the water levels in the wave pool can be successfully
and simply managed using two 280,000 litre water tanks, one with an unsealed base for disposal
of excess water via infiltration and one for storage for top up during dry periods. This may still result
in some “down” days where the water level in the pool exceeds the operational tolerance level, so
there is an option to double the number of tanks to reduce (or virtually eliminate) any “down” days.




Doug Reynolds, Director – Civil Group
PREQ 9072
07 5449 9600 | [email protected]