Council archive · source document
Attachment 8 - Environmental Noise Assessment · MCU23/0078
• Outdoor dining was predicted from the outdoor dining area. The noise duration was assumed to be
continuous during the assessment time period. The sound level includes allowance for low-level
background amplified music.
• Offsite receivers: Noise attenuation of 7dB through an open window at a receiver was applied for
internal predictions. It is noted that between 15 and 20dB could be expected to be achieved through a
closed window or door with standard construction.
• Onsite receivers: Internal predictions include façade attenuation as habitable room facades are able to
be designed and constructed to a specified acoustic rating for onsite receivers. Façade construction for
habitable rooms to achieve a minimum noise attenuation of 25dB. Façade construction for habitable
rooms adjacent to the plaza area (outdoor dining) to achieve a minimum noise attenuation of 30dB.
• Noise source locations are shown in Figure 6.
- 1: Deliveries, Waste collection, Roller Door, Compactor
- 2: Car door closure, Car engine start, Conversation
- A: Truck pass by / manoeuvring
- B: Car
Figure 6: Noise Source Locations – Proposed Development
Site: Eenie Creek Road, Noosaville 24
Reference: 22BRA0078 R01_4
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Attachment 8 - Environmental Noise Assessment.pdfRelated documentApplication case desk ↗
About this file
- File size
- 5.1 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.