Details regarding sound reduction requirements are presented in Table 25
Table 25: Recommended Residential Building Attenuation
Required Acoustic Rating (R w ) for Habitable Rooms
QDC Noise
Category Glazing Glazing External Walls Roof and Ceiling
> 1.8m 2 * ≤ 1.8m 2 *
Category 2 RW 35 RW 32 RW 41 RW 38
Category 1 RW 27 RW 24 RW 35 RW 35
*Glazing area refers to total glazing area in a room, not the area of a single window / sliding door.
Based on sound reduction requirements from Queensland Development Code MP4.4, Schedule 1 (Appendix D)
8.2 Management Strategies
The following management strategies are recommended:
a. Operating hours as outlined in Section 3.1 (which are predominately in accordance with the code
acceptable outcomes).
b. Balconies to have solid balustrades at Receiver A (all southwest façades) and Receiver D (northeast
facade) .
c. Amplified music for restaurants to be limited to low level background music only.
d. Any speed humps should be bitumen, concrete (as part of the slab) or rubber, not metal.
Site: Eenie Creek Road, Noosaville 36
Reference: 22BRA0078 R01_4
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Attachment 8 - Environmental Noise Assessment.pdfRelated documentApplication case desk ↗
About this file
- File size
- 5.1 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.