Council archive · source document
Attachment 8 - Environmental Noise Assessment · MCU23/0078
ect Ere Crd oe a De Ree eee Co) Two leaves of clay brick masonry at least 110mm thick with cavity not less than 50mm between leaves OR Single leaf of clay brick masonry at last 110mm thick with: (i) a rowof at least 70mm x 35mm timber studs or 64mm steel studs at 600mm centres, spaced at least 20mm from the masonry wall; and (i) mineral insulation or glass wool insulation at least 50mm thick with a density of at least 11 kg/m? positioned between studs; and (ii) One layer of plasterboard at least 10mm thick fixed to outside face of studs OR Single leaf of brick masonry at least 110mm thick with at least 13mm thick render on each face OR Concrete brickwork at least 110mm thick OR In-situ concrete at least 100mm thick OR Precast concrete at least 100mm thick and without joints. Version 1.1 ed Co Oe Cd TTT Page 11 Publication Date: 17 August 2015 ee een) Single leaf of clay brick masonry at least 110mm thick with (i) arowof at least 70mm x 35mm timber studs or 64mm steel studs at 600mm centres, spaced at least 20mm from the masonry wall; and (i) One layer of plasterboard at least 10mm thick fixed to outside face of studs 35 OR Minimum 6mm thick fibre cement sheeting or weatherboards or plank cladding externally, minimum 90mm deep timber stud or 92mm metal stud, standard plasterboard at least 13mm thick internally Concrete or terracotta tile or sheet metal roof with sarking, acoustically rated plasterboard ceiling at least 13mm thick fixed to ceiling joists, cellulose fibre insulation at least 100mm thick with a density of at least 45kg/m? in the cavity. 45 OB Concrete or terracotta tile or sheet metal roof with sarking, 2 layers of acoustically rated plasterboard at least 16mm thick fixed to ceiling joists, glass wool insulation at least 50mm thick with a density of at least 11kgim? or polyester insulation at least 50mm thick with a density of at least 20kg/m? in the cavity. Roof Concrete or terracotta tile or metal sheet roof with sarking, plasterboard ceiling at least 10mm thick fixed to ceiling joists, glass wool insulation at least 50mm thick with a density of at least 11kg/m? or polyester insulation at least 50mm thick with a density of at least 20kg/m? in the cavity 41 OR Concrete suspended slab at least 100mm thick Concrete or terracotta tile or metal sheet roof with sarking, plasterboard ceiling at least 10mm thick fixed to 38 ceiling cavity, mineral insulation or glass wool insulation at least 50mm thick with a density of at least 11 kg/m? Version 1.1 Page 12 Publication Date: 17 August 2015 m 64
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Attachment 8 - Environmental Noise Assessment.pdfRelated documentApplication case desk ↗
About this file
- File size
- 5.1 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.