Council archive · source document
Scg 31263(L3) · OPW22/0106
Attached to the e-mail Information Request Response OPW22/0106 - 31 McAnally Dr, Sunshine Beach.
Attached to the e-mail Response to Information Request OPW22/0106 - 31 McAnally Dr, Sunshine Beach.
19 May 2022
SCG Ref: 31263(L3)
By email: [email protected]
Maryanne Edwards & David Carlson
C/- Chris Clout Design
Dear Maryanne & David
Re: Information Request OPW22/0106 – 31 McAnally Drive, Sunshine Beach
We have reviewed Noosa Council’s Information Request dated 4/05/2022 and respond to the engineering aspect
below.
Issue
The submitted documentation indicates that the proposed driveway will require minor earthworks (cut) within the
road reserve. Council have concerns regarding the impact the cut will have on the natural surface and the potential
creation of trip hazards within the road reserve.
Response
The existing and proposed road reserve is not accessible by pedestrian traffic, we do not see any risk
regarding trip hazards. Furthermore, the neighbouring property (No. 35 McAnally Drive) driveway is cut into
natural ground with a timber retaining wall. The proposed minor cut for the proposed driveway will be further
reducing surface slopes within the road reserve, thus improving existing conditions.
Issue
The submitted plans do not include sufficient information on the access driveway and manoeuvring area.
Response
Please refer SCG drawing number 31263-OW2.1 and OW2.2, which outlines driveway levels, grades
and dimensions for the proposed driveway and manoeuvring area. We have amended our plan to note
for the existing crossover to be removed and replaced with a new kerb and channel and landscaping to
Council standards.
Issue
The provided documentation does not include a stormwater diversion grate at the base of the driveway and garage
pad. Council is concerned that the stormwater collected from the driveway will pool at the bottom of the driveway
and create potential flooding within the garage.
Response
The proposed driveway falls at approximately 2-2.5% away from the building increasing to 10-12.5.% in the
road reserve. There is no risk for any localised flooding/pooling to the garage. Furthermore, internal
drainage is to be designed by an internal Hydraulic Consultant and endorsed through a building permit.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 1 page
Page 2
If you have any further questions, please do not hesitate to contact our office.
Yours faithfully
Checked by
TOM HARRINGTON SEAN RICHARDSON – RPEQ 5835
For and on behalf of For and on behalf of
SCG CONSULTING ENGINEERS SCG CONSULTING ENGINEERS
SCG Consulting Engineers Page 2 of 2 SCG Ref: 31263(L3)