164 Edwards St - Duplex MCU App - App A Proposed Plans
Plans and drawings
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawnLANDSCAPING NOTES PLANT LEGEND
MINIMUM DENSITY REQUIRED: TREES:
SHRUBS 1.5 METRE CENTRES ALL 45L TREES AND LARGE SHRUBS WILL NEED TO BE Star Jasmine Vine
SMALL SHRUBS / GROUNDCOVERS 0.5 - 1 METRE CENTRES STAKED SECURELY USING 1800MM STAKES X 2 OR 3
AS NECESSARY AND TIED TO STAKES USIND HESIAN
USE MATURE PLANTS WHEREVER POSSIBLE; MINIMUM WEBBING, (TO PREVENT PLANT DAMAGE UNTIL Heath Grasstree
SIZING REQUIRED: ESTABLISHED).
FEATURE TREES 45LT
STREET TREES 25LT MULCH: Dichondra Silver Falls
OTHER TREES 300MM ALL GARDENS ARE TO BE MULCHED WITH 'PINE BARK'
LARGE SHRUBS 200MM MULCH TO A MINIMUM DEPTH OF 100MM , TO BE
GROUNDCOVERS 150MM KEPT 50MM FROM STEMS OF PLANTS TO AVOID COLLAR Cousin It
ROT.
PREPARATION OF GARDEN BEDS FOR PLANTING:
CULTIVATE EXISTING SOIL IN NATURAL GROUND TO A DRAINAGE: m Heliconia
MINIMUM DEPTH OF 150MM. IMPORT CLEAN TOPSOIL ENSURE ADEQUATE DRAINAGE IS INSTALLED 38.0
(SANDY LOAM) TO A MINIMUM DEPTH OF 300MM, BELOW GARDENS AND PAVED AND CONCRETED AREAS.
ABOVE ORIGINAL GROUND LEVEL. ORGANIC MATTER, OR Lomandra confertifolia
GYPSUM ETC, MAY ALSO BE ADDED AS NECESSARY
TO IMPROVE THE SOIL FOR THE BEST POSSIBLE GROWTH.
TEST THE SOIL USING A 'SOIL TEST KIT' TO ENSURE IT IS Rhapis Palm
HEALTHY AND AMEND AS NECESSARY. PLUNGE POOL DECK
RL. 37.8 m
ALL GARDEN BEDS TO BE MOUNDED 300MM MIN 2.48m x 4.8m
AT CENTRE OF BED, ABOVE FINISHED PAVEMENT
LEVELS, TO PREVENT ANY PONDING AROUND PLANTS. BLOCK DIVIDING FENCE Fraser Island Apple
FERTILIZE USING A SLOW RELEASE FERTILIZER IN 'PILL' OR MAX. 2m HT GABION RETAINING WALL 1250mm HT
'GRANULE' FORM, AT TIME OF PLANTING, ENSURE THAT POOL SAFE (NON - CLIMBABLE)
FERTILIZER DOES NOT DIRECTLY CONTACT ROOTS.
LAWN CL LAWN LAWN Bromeliad
MAINTENANCE: RL. 36.35 m RL. 36.35 m
PROPOSED
A MAINTENANCE REGIME MUST BE PROGRAMMED TO BALCONY
CONCRETE STEPPERS
MAINTAIN MULCH, WATER, FERTILIZER, PRUNING AND THE Groundcover
CARE AND/OR REPLACMENT OF ANY DAMAGED OR GABION RETAINING WALL
Blue Chalksticks / Pigface
DISEASED PLANT.
SHORT TERM:
FOR THE FIRST FOUR WEEKS ALL PLANTS MUST BE LOT 108 PROPOSED DUAL OCCUPANCY
CL
WATERED FOR A MINIMUM OF 20MINS PER DAY
REDUCING TO 10MINS PER DAY FOR FOLLOWING 5 511.8m² Wallum Banksia
MONTHS (ALWAYS WATER IN RELATION TO RAINFALL).
GRAVEL
IRRIGATION:
PARTY WALL (SHOWN DASHED)
INSTALL AN AUTOMATIC IRRIGATION / DRIP SYSTEM
WITH TIMER TO ALL NEW LAWNS & GARDENS.
PLACE IRRIGATION LINE AFTER PLANTING AND
PRIOR TO MULCHING. UNIT 1 UNIT 2
USE ONLY SUN 'HARDENED' PLANTS. ENSURE
EXTERNAL WALLS BELOW (SHOWN DASHED)
HEALTHY ROOT SYSTEM TO ALL PLANTS TO BE USED.
UNDER NO CIRCUMSTANCES ARE ROOT BOUND PLANTS
TO BE USED.
PROPOSED PROPOSED
e
PLUNGE POOL DECK DRIVEWAY BLOCK RETAINING >1.5m
2.4m x 4.8m RL. 36.5 m RL. 35.55 m
6000 OMP
3520 POOL OMP
e
BIN STORE AND SCREENING
n
nb
s s s s s s s
CARPARK IL33.62 (DROP DOWN)
s s s
IL33.16 s
e
s s s s s s s
34.65
1000
SEWER MANHOLE
e
LB
34.60 NOTE:
n
SCREW
nb
35.74 LANDSCAPING MUST BE IN ACCORDANCE WITH NOOSA PLAN 2020 9.4.5
N
e
FH
GARDEN 500 MAX
NEW PANDANUS TREE EXISTING PANDANUS TREE WATER VALVE LANDSCAPING CODE AND SC6.3 PSP2 LANDSCAPING
w w w w w w w w w w w w w w w w w w
PP nbn nbn POOL AND RETAINING WALLS WITHIN THE FRONT 6m SETBACK MUST NOT
nbn nbn nbn nbn nbn nbn nbn nbn
e
e e e e PROTRUDE MORE THAN 1m ABOVE NGL
e e e e e e e e e e e e PP
e
m
1500
LANDSCAPING TO 40% OF SITE, OF WHICH 60% OF THAT PERCENTAGE SHOULD BE
m
m
.0
SOFT LANDSCAPING
0
.0
35
36.
34
Landscaping Plan
1 1 : 150
RETAIN EXISTING VEGETATION FOR NATURAL SHADING WHERE POSSIBLE
LANDSCAPING MUST NOT ENCROACH MORE THAN 500mm INTO THE ROAD RESERVE
6/10/2021 9:37:50 PM
For engineering information, Engineer's drawings and information shall take precedence over architectural drawings. 164 Edwards Street, Date: Rev: Issue: Scale: Title: Date:
Client Project
Amendments
The Building Designer's drawings and recommendations shall take precedence over architectural drawings. The
05.10.2021 B Outdoor Area Roof & Landscape Plan As L a n d s c a p i n g P l a n 05.10.2021
Job Details
author is to be notified immediately, should any errors, discrepancies, or conflict become apparent and prior to Sunshine Beach
Copyright
proceeding with the works. indicated
Copyright: The design content shown on this drawing remains the property of Garland Design and is provided only
for the use described. This drawing may not be copied, altered, have sections omitted, erased or changed in any Des: JC Project #: Drawing #: Issue:
way without the prior written approval of Garland Design. Adam Flanagan & Shane Tye Check:JC 21.107 WD.2.07 B
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.