Council archive · source document
Info Request OPW17/0150
Officer :Mark Lewis Direct Telephone: 07 53296290 Fax: 07 53296501 Our Reference :MLEWIS:OPW17/0150 Your Reference :180 Gympie Terrace. 22 May 2017 Pile-It Pty Ltd PO Box 672 NOOSAVILLE QLD 4566 Dear Sir/Madam Information Request Sustainable Planning Act 2009 I refer to your application and advise that Council requires further information to satisfactorily assess the proposal. application details Application No: OPW17/0150 Proposal: Development Permit for Operational Works – Prescribed Tidal Works - Jetty Extension and Pontoon Street Address: Jetty 180 Gympie Tce NOOSAVILLE QLD 4566 Real Property Description: Lot 163 CP 907408 information required The information requested is set out below: Issue Council has some concerns with the submitted “jetty plan and details”. The submitted plan: does not indicate the existing arrangement of jetties and pontoons does not clearly indicate which existing structures are being located and the new location does not indicate the existing mooring piles The boundaries shown are not in accordance with CP907408. There appears to be an additional boundary of 4.0 metres on the eastern side Information Required Provide an amended “jetty plan and details” that addresses the concerns mentioned above Issue The submitted Form 15 from SCG Consulting Engineers does not make reference to the IDAS Code of the Coastal Protection and Management Regulation Information Required Provide an amended Form 15 that makes reference to the relevant sections of the IDAS Code of the Coastal Protection and Management Regulation Issue Council has concerns with the submitted plans relating to the new pontoon prepared by Superior Jetties. The plans are not endorsed by a Registered Professional Engineer of Queensland (RPEQ) and no certification has been provided. Information Required Provide plans of the proposed pontoon that are endorsed by a Registered Professional Engineer of Queensland (RPEQ). Provide plans that have the correct boundary dimensions Provide plans of the proposed gangway Provide certification from a Registered Professional Engineer of Queensland (RPEQ) that states that the proposed pontoon and access ramp (gangway) are in accordance with the relevant sections of the IDAS Code of the Coastal Protection and Management Regulation End of Information Request Under the provisions of the Sustainable Planning Act 2009, you have three options available in response to this Information Request. You may give the assessment manager (in this instance Council) and each referral agency (if any): all of the information requested; or part of the information requested together with a letter asking the assessment manager and each referral agency to proceed with the assessment of the application; or a letter; stating that you do not intend to supply any of the information requested; and asking the assessment manager and each referral agency to proceed with the assessment of the application. Please be aware that under Section 279 of the Sustainable Planning Act 2009 the applicant must respond to the Information Request within 6 months of the request or otherwise the application lapses. A response to the above is required to be submitted, prior to further assessment of the application. If any further matters arise as part of assessment of this application, you will be advised accordingly. Council prefers that all the information requested be submitted as one package. A preliminary assessment only of the application has been undertaken and during the formal decision stage, or as a result of public exhibition, other matters may arise. You may wish to follow the progress of this application online at www.noosa.qld.gov.au . The “PD Online” page can be accessed via "Quick Links" on the left hand side of the screen. A disclaimer will appear; upon clicking “agree”, a search for a development application or property address can be carried out. Should you have any further queries in relation to the above, please do not hesitate to contact Mark Lewis on the above number. Yours faithfully Mark Lewis coordinator engineering [word/footer1.xml] Page 2 of 3 [word/footer2.xml] PO Box 141 P. (07) 5329 6500 [email protected] TEWANTIN QLD 4565 F. (07) 5329 6501 www.noosa.qld.gov.au Page 1 of 3 [word/header1.xml] OPW17/0150
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Info Request OPW17/0150Related documentApplication case desk ↗
About this file
- File size
- 66 KB (small file)
- File type
- DOCX
No other editions are linked here.